• 제목/요약/키워드: Absolute measurement

검색결과 591건 처리시간 0.027초

딥러닝 기반의 TSV Hole TCD 계측 방법 (Deep Learning Based TSV Hole TCD Measurement)

  • 정준희;구창모;조중휘
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.103-108
    • /
    • 2021
  • The TCD is used as one of the indicators for determining whether TSV Hole is defective. If the TCD is not normal size, it can lead to contamination of the CMP equipment or failure to connect the upper and lower chips. We propose a deep learning model for measuring the TCD. To verify the performance of the proposed model, we compared the prediction results of the proposed model for 2461 via holes with the CD-SEM measurement data and the prediction results of the existing model. Although the number of trainable parameters in the proposed model was about one two-thousandth of the existing model, the results were comparable. The experiment showed that the correlation between CD-SEM and the prediction results of the proposed model measured 98%, the mean absolute difference was 0.051um, the standard deviation of the absolute difference was 0.045um, and the maximum absolute difference was 0.299um on average.

국내 통합기준점에서 지자기 편각 조사의 타당성 연구 (A Study on the Feasibility of Geomagnetic Declination Investigation at Unified Control Points in South Korea)

  • 이용창
    • 대한공간정보학회지
    • /
    • 제24권3호
    • /
    • pp.29-38
    • /
    • 2016
  • 우주전파환경 변화의 중요성과 스마트 폰 및 드론과 같은 지자기 방향성과 연계된 전자장비의 보편화로 지자기 편각성분에 대한 효율적인 관측 방안 및 지자기 교란 영향에 대한 연구의 필요성이 높아지고 있다. 본 연구의 목적은 교외에 설치된 통합기준점을 방위표지로 한 지자기 편각관측의 타당성을 검토하는 것이다. 이를 위해 국내 중앙에 위치하며 INTERMAGNET에 가입된 청양 지자기관측소 자료를 활용하여 지자기 성분의 일변화 및 교란수준을 KP, KK와 연계하여 상관성을 분석하였다. 국내 지역 내, 통합기준점 3곳 및 개활지 1곳에 대한 지자기편각 관측을 수행하였다. 통합기준점을 활용한 편각측정의 타당성 검토를 위한 비교 기준으로 세계지자기모델을 선정하고 모델 값과 절대 관측 값 및 모델간의 편각편차를 비교 분석하였다. 연구결과, 교외 통합기준점을 방위표지로 활용한 지자기 편각성분의 절대관측의 적합성을 확인할 수 있었다.

평면 LED 램프에서의 초음파 센서의 반사특성을 고려한 위치측정 기법 (Location Measurement method Depending on Reflection Characteristics of Ultrasonic Sensors for The Flat LED Lamp)

  • 허영록;윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.38-43
    • /
    • 2013
  • In this paper, the location measurement method for the reliable location data using ultrasonic sensors is proposed for the dimming control of the LED flat lamp. The measurement errors depending on the reflection angle of the object have to be considered to obtain the reliable location data in the ultrasonic sensors. In the experiment, the cause of the measurement errors depending on reflection angle is analyzed and velocity change of ultrasonic wave depending on reflection angle is measured. And the location measurement method depending on velocity change of ultrasonic wave is proposed. From the results, the average absolute deviation of the x-coordinates was 1.47cm when the location measurement method was considered, and it was closer to the true values than the average absolute deviation of the x-coordinates which was 5.89cm without regard to the reflection angle.

대전지자기관측소에서 측정된 지자기 값과 시간에 따른 변화 (Geomagnetism measured in DZN (Daejeon) Geomagnetic Observatory and its time-variation)

  • 임무택;박영수;임형래;구성본;이영철;나재신
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.353-360
    • /
    • 2007
  • KIGAM has installed a FLARE+ continuous geomagnetic observation system in 1998 in Daejeon of which the IAGA identification code is DZN. The coordinates of the absolute measurement plinth precisely determined by the PDGPS(Post-Processing Differential Global Positioning System) is (127-21-37.19E, 36-22-43.96N, 45.93 m) in WGS84 for the horizontal and from the geoid surface for the vertical. Periodically we have conducted the absolute geomagnetic measurement on the plinth above. We have processed the continuous time-variation 3-axis geomagnetic data measured on arbitrary sensors' coordinates in the observatory and absolute geomagnetic data together to get as the results the time-variation H(orizontal), D(eclination), Z(vertical down), F(scalar calculated from 3 components) and P(Proton Precession Magnetometer Data). We have compared our own data with those calculated from the 10th generation IGRF(International Geomagnetic Reference Field). All the measured data in the DZN Observatory can be acquired through the website http://geomag.kigam.re.kr.

  • PDF

Autonomous Real-time Relative Navigation for Formation Flying Satellites

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • 제26권1호
    • /
    • pp.59-74
    • /
    • 2009
  • Relative navigation system is presented using GPS measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide the real-time inter-satellite relative positions as well as absolute positions for two formation flying satellites in low earth orbit. To improve the navigation performance, the absolute states are estimated using ion-free GRAPHIC (group and phase ionospheric correction) pseudo-ranges and the relative states are determined using double differential carrier-phase data and singled-differential C/A code data based on the extended Kalman filter and the unscented Kalman filter. Furthermore, pseudo-relative dynamic model and modified relative measurement model are developed. This modified EKF method prevents non-linearity of the measurement model from degrading precision by applying linearization about absolute navigation solutions not about the priori estimates. The LAMBDA method also has been used to improve the relative navigation performance by fixing ambiguities to integers for precise relative navigation. The software-based simulation has been performed and the steady state accuracies of 1 m and 6 mm ($1{\sigma}$ of 3-dimensional difference errors) are achieved for the absolute and relative navigation using EKF for a short baseline leader/follower formation. In addition, the navigation performances are compared for the EKF and the UKF for 10 hours simulation, and relative position errors are mm-level for the two filters showing the similar trends.

FG-5 절대중력계 사례조사 연구 (Case Study on Absolute Gravity Measurement using FG-5)

  • 이영진;손수익;이명준;정광호
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.197-199
    • /
    • 2010
  • A gravity survey is a base of research earth gravity field determined, perception of the vertical motion, change of Geoid, sea-level changes, climate change etc. Recently, FG-5 was adopted in NGII. NGII has completed 4 points of absolute gravity survey and 1,400 points of relative gravity survey in 2009 to aim to observe 20 points of absolute gravity survey and 6,000 points of gravity control point by 2013. Using results of gravity survey, NGII will provide citizen with data for research about renewal of geoid model and geophysics. This study aims to go over examples of utilization of absolute gravimeter & method of utilization in korea.

  • PDF

특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화 (Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition)

  • 이승민;박대진
    • 대한임베디드공학회논문지
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

유량측정 방법의 정확도 분석 -괴산댐 하류 달천 적용 사례를 중심으로- (Inter-comparison of Accuracy of Discharge Measurement Methods - A Case Study Performed in the Dalcheon River Downstream of the Goesan Dam-)

  • 이찬주;김동구;권성일;김원
    • 한국수자원학회논문집
    • /
    • 제43권12호
    • /
    • pp.1039-1050
    • /
    • 2010
  • 본 연구에서는 괴산댐 하류 달천에서 6가지 직접 유량 측정 방법-유속면적법, 봉부자법, ADCP이동측정법, ADCP정지 측정법, 전자파표면유속계, LSPIV-을 적용하고, 이를 댐 방류량 및 유속면적법과 비교함으로써 정확도를 상호 평가하였다. 이를 위해 2005년부터 2010년까지 실시된 총 39회의 유량측정결과가 분석되었다. 댐 방류량과의 비교 결과, 봉부자법을 제외한 나머지5가지 방법은 평균 6.2% 이내의 절대값오차를 나타냈다. 유속면적법과 다른 4가지방법을 비교할 경우, 전자파표면유속계는 7.35%, 나머지 3가지 방법은 6% 이내의 절대값오차를 나타냈다. 봉부자법은 댐 방류량 및 유속면적법과 비교하여도 오차의 범위가 크게 나타났는데, 이에 대해서는 추가적인 검증이 필요하다.