• 제목/요약/키워드: Absolute Temperature

검색결과 477건 처리시간 0.023초

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

적외선(赤外線) 체열(體熱) 촬영(撮影)을 이용한 족삼리(足三里)(ST36)자침(刺鍼)이 안면부(顔面部) 영역간(領域間) 온도차이(溫度差異)의 변화(變化)에 미치는 영향(影響) (Study on facial thermographic change of D.I.T.I. by acupuncture on Zusanli(ST36))

  • 조은희
    • Journal of Acupuncture Research
    • /
    • 제20권5호
    • /
    • pp.107-117
    • /
    • 2003
  • Objective: This study was examined for effects of acupuncture of Zusanli(ST36) on the facial thermography in health subjects. Methods: The voiunteers who participating in this study had taken rest for 15 mins in room temperature ($19-21^{\circ}C$) before the examination and informed them what to prohibit smoking. drinking and administration of drug for the previous day. The thermography of face was taken using Digital Infrared Thermographic Imaging (D.I.T.I.: Dorex. DTI-16UT1. U.S.A.) by time interval of 35 minutes at 15 min before and 20 min after acupuncture stimuiation. Thermal temperature of Daying(ST5). Juliao(ST3) and Quanliao(SI18) was measured and compared. Results: The results showed that acupuncture of Zusanli(ST36) significantly decreased the Absolute defference of temperature between Daying(ST5) and Juliao(ST3) (p<0.05, Data were represented meant ${\pm}$S.E.M.(n=33)). The results showed that acupuncture of Zusanli(ST36) significantly decreased the Absolute defference of temperature between Quanliao(SI18) and Juliao(ST3)(p<0.01, Data were represented mean${\pm}$S.E.M. (n=33)). But, acupuncture of Zusanli(ST36) particularly decreased the absolute defference of temperature between Daying(ST5) and Quanliao(SI18). Also. it was observed that acupuncture of ST36 decreased variety of the color tone of thermographic contour line and decreased thermal distribution. Conclusions: The results showed that acupuncture of Zusanli(ST36) significantly decreased the absolute defference of temperature of partial facial surface. Hereafter. study about if acupuncture of Zusanli(ST36) significantly decrease the absolute defference of temperature of all the areas of facial surface is requested. Also. continued study of effects of acupuncture of other meridian on the facial thermography is requested.

  • PDF

D.I.T.I.를 이용한 족삼리(ST36)자침이 안면부 절대온도변화에 미치는 영향 (Characteristics of Acupuncture at Chok-Samni(ST36) on Facial Thermographic Change of D.I.T.I.)

  • 조은희;박민철;최덕화
    • 동의생리병리학회지
    • /
    • 제17권6호
    • /
    • pp.1493-1499
    • /
    • 2003
  • This study was examined for effects of acupuncture of Chok-Samni(ST36) on the facial thermography in health subjects, The volunteers who participating in this study had taken rest for 15 mins in room temperature (19-21 ℃) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day, The thermography of face was taken using Digital Infrared Thermographic Imaging (D.I.T.I. : Dorex, DTI-16UT1, U.S.A.) by time interval of 35 minutes at 15 min before and 20 min after acupuncture stimulation. Thermal temperature of Yangbaek(GB14), Myon-koryo(ST3) and Chichang(ST4) was measured and compared, The results showed that acupuncture of Chok-Samni(ST36) decreased the Absolute difference of temperature between Myon-koryo(ST3) and Chichang(ST4) (p<0,05, Data were represented mean±S,E.M.(n=33)), But, acupuncture of Chok-Samni(ST36) particularly decreased the absolute difference of temperature between Yangbaek(GB14) and Chichang(ST4) and particularly decreased the absolute difference of temperature between Vangbaek(GB14) and Myon-koryo(ST3) (p<0,05, Data were represented mean±S,E.M.(n=33)). Also, it was observed that acupuncture of Chok-Samni(ST36) decreased variety of the color tone of thermographic contour line and decreased thermal distribution. The results showed that acupuncture of Chok-5amni(ST36) significantly decreased the absolute difference of temperature of partial facial surface. Hereafter, study about if acupuncture of Chok-Samni(ST36) significantly decrease the absolute difference of temperature of all the areas of facial surface is requested. Also, continued study of effects of acupuncture of other meridian on the facial thermography is requested.

온도 및 공정 보상 전류 미러를 이용한 정밀한 전류 레퍼런스 (An Accurate Current Reference using Temperature and Process Compensation Current Mirror)

  • 양병도
    • 대한전자공학회논문지SD
    • /
    • 제46권8호
    • /
    • pp.79-85
    • /
    • 2009
  • 본 논문에서는 온도 및 공정 보상 전류 미러(temperature and process compensation current mirror: TPC-CM)를 이용한 정밀 전류 레퍼런스를 제안하였다. 온도 변화에 영향을 받지 않는 기준 전류는 절대 온도에 비례하여 증가하는 PTAT (proportional to absolute temperature) 전류와 온도에 반비례하여 감소하는 CTAT(complementary to absolute temperature) 전류의 합으로 생성된다. 그러나 온도 계수(temperature coefficient)와 기준 전류의 크기는 공정 변화에 크게 영향을 받는다. 이런 공정 변화를 보정하기 위하여, 제안된 TPC-CM에서는 온도 계수와 기준 전류의 크기를 조절하는 두 개의 이진 가중치 전류 미러(binary weighted current mirror)를 이용하였다. 제작된 각 칩마다 PTAT 전류와 CTAT 전류를 측정한 후, 기준 전류의 크기가 온도에 상관없이 일정하도록, TPC-CM의 스위치 코드를 결정하고 그 값을 비휘발성 메모리에 저장한다. 시뮬레이션에서 TPC-CM는 공정변화 영향을 19.7%에 서 0.52%로 줄였다. 제안된 전류 레퍼런스는 3.3V 0.35um CMOS 공정을 이용하여 제작되었으며, 측정된 칩의 기준 전류 변화율은 $20^{\circ}$C${\sim}$100$^{\circ}$C에서 0.42%였다.

냉각평판에 형성된 서리층의 물성치 (Properties of the Frost Layer Formed on a Cold Flat Surface)

  • 김성곤;양동근;이관수
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.374-380
    • /
    • 2003
  • This paper proposes dimensionless correlations predicting properties of the frost layer formed on a cold flat surface. Experiments are carried out to obtain the correlations with various environmental parameters such as air temperature, air velocity, absolute humidity, and cooling plate temperature. As a result, the frost properties (frost layer thickness, density, surface temperature, thermal conductivity) are correlated as a function of Reynolds number, Fourier number, absolute humidity and non-dimensional temperature by using a dimensional analysis. The correlations agree well with the previous and our experimental data within a maximum error of 10%, and are used to predict the frost properties in the following ranges: Reynolds number of 20216 to 53763, Fourier number of 0.1962 to 2.5128, absolute humidity of 3.22 to 8.47, and non-dimensional temperature of 0.125 to 0.5.

실효온도차법에 의한 최대열부하 계산용 온습도에 관한 연구 (Design Temperature and Absolute Humidity for Peak Cooling and Heating Load Calculation with ETD Method)

  • 김두천;서진석
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.278-284
    • /
    • 1993
  • A simplified TAC method was developed for the selection of design temperature and absolute humidity for peak cooling and heating load calculation with ETD method. And the design data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the design data for summer and autumn cooling season were selected by the TAC 5.0% of July through August and TAC 5.0% of October, respectively. But the design data for winter heating season were selected by the conventional TAC 2.5% of the full winter season.

  • PDF

온도의 영향성을 고려한 리튬폴리머 전지의 절대용량 추정 방법 (Absolute Capacity Estimation Method with Temperature Effect for a Small Lithium-polymer Battery)

  • 김한경;곽기호
    • 한국군사과학기술학회지
    • /
    • 제19권1호
    • /
    • pp.26-34
    • /
    • 2016
  • Military devices and systems powered by batteries need to operate at extreme temperature and estimate the available capacity of the battery at different temperature conditions. However, accurate estimation of battery capacity is challenging due to the temperature-sensitive nature of electrochemical energy storage. In this paper, Peukert's equation with temperature factor is derived, and methods for estimating the absolute capacity of lithium-polymer battery and the state-of-charge(SOC) with respect to varying currents and temperatures are presented. The proposed estimation method is experimentally verified under three different discharge currents(0.5 A, 1 A, 3 A) and six different temperatures ranging from -30 to 45 deg. C. The results show the proposed method reduces the Peukert's estimation error by up to 30 % under or at extreme condition.

도로 및 기상조건을 고려한 노면온도변화 패턴 추정 모형 개발 (Developing Models for Patterns of Road Surface Temperature Change using Road and Weather Conditions)

  • 김진국;양충헌;김승범;윤덕근;박재홍
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.127-135
    • /
    • 2018
  • PURPOSES : This study develops various models that can estimate the pattern of road surface temperature changes using machine learning methods. METHODS : Both a thermal mapping system and weather forecast information were employed in order to collect data for developing the models. In previous studies, the authors defined road surface temperature data as a response, while vehicular ambient temperature, air temperature, and humidity were considered as predictors. In this research, two additional factors-road type and weather forecasts-were considered for the estimation of the road surface temperature change pattern. Finally, a total of six models for estimating the pattern of road surface temperature changes were developed using the MATLAB program, which provides the classification learner as a machine learning tool. RESULTS : Model 5 was considered the most superior owing to its high accuracy. It was seen that the accuracy of the model could increase when weather forecasts (e.g., Sky Status) were applied. A comparison between Models 4 and 5 showed that the influence of humidity on road surface temperature changes is negligible. CONCLUSIONS : Even though Models 4, 5, and 6 demonstrated the same performance in terms of average absolute error (AAE), Model 5 can be considered the optimal one from the point of view of accuracy.

가연성물질의 자연발화온도 측정 및 예측 - 메탄올과 에탄올 - (Measurement and Prediction of Autoignition Temperature(AIT) of Flammable Substances - Methanol and Ethanol -)

  • 하동명
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.54-60
    • /
    • 2004
  • Flammable substances are frequently used chemical industry processes. An accurate knowledge of the ALTs(Autoignition Temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, ignition delay. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for methanol and ethanol. The A.A.P.E.(Average Absolute Percent Error) and the A.A.D.(Average Absolute Deviation) of the experimental and the calculated delay times by the AITs for methanol were 14.59 and 1.76 respectively. Also the A.A.P.E. and the A.A.D. of the experimental and the calculated delay times by the ATIs for ethanol were 8.33 and 0.88.

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • 제1권1호
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.