• Title/Summary/Keyword: Abnormal voltage

Search Result 192, Processing Time 0.022 seconds

Bickerstaff's Brainstem Encephalitis Treated with Immunoglobulin (면역글로불린으로 치료한 Bickerstaff 뇌간뇌염 1예)

  • Kim, Beom Joon;Choi, Yoon Jae;Kim, Nam-Hee;Hong, Yoon-Ho;Sung, Jung-Joon;Han, Moon-Ku;Park, Seong-Ho;Lee, Kwang-Woo;Park, Kyung Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.8 no.1
    • /
    • pp.94-97
    • /
    • 2006
  • Bickerstaff's brainstem encephalitis (BBE) is a rare disorder with acute ophthalmoparesis, ataxia, consciousness disturbance, and pyramidal signs of suspected autoimmune origin. A-62-year-old woman developed acute diplopia, dysarthria, gaze-paretic nystagmus and gait ataxia. Her mental status fell subsequently into stupor. Brain MRI and nerve conduction study showed no significantly abnormal findings. Electroencephalography revealed diffuse low voltage slowings. After treating with intravenous immunoglobulin, she demonstrated rapid clinical recovery. This case suggests that immunoglobulin can be an alternative option in BBE treatment, especially when plasmapheresis and corticosteroids are difficult or contraindicated.

  • PDF

Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system (고속전차선로 유리애자 현장 적합성 기초연구)

  • Jeon, Yong-Joo;Ryu, Young-Tae;Lee, Gi-Chun;Lee, Yoo-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.423-427
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System (태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Un-Ki;Lim, Hyun-Sung;Song, Young-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.

Calculation of Inrush Current of a Transformer using FEM (유한요소법에 의한 변압기의 돌입전류 계산)

  • 이준호;이기식
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1999
  • The inrush current of transformer can flow when the overvoltage caused by surge or external faults is applied. In this paper, an algorithm for the calculation of this inruch current is proposed. The capacitances of windings are precalculated by using 3 dimensional FEM and are appended to circuit of the transformer. And transient characteristics of the transformer are analyzed by axisymmetric FEM which is coupled magnetic field of transformer and circuit of transformer. When a transformer encounters abnormal voltage, using the proposed method, internal magnetic field of transformer, voltages and currents of windings are calculated.

  • PDF

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.

Preliminary Design of Power Control and Distribution Unit for LEO Application (저궤도 위성 응용을 위한 전력조절분배기 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Baek;Jang, Sung-Soo;Lee, Sang-Kon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.55-57
    • /
    • 2007
  • A Power control and Distribution Unit (PCDU) plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. In this work, we perform the preliminary design of a PCDU for the small Low Earth Orbit (LEO) Satellite applications. The main constitutes of the PCDU are the battery interface module, solar array regulators with maximum power point tracking (MPPT) technology, heater power distribution modules, internal converter modules for regulated bus voltage generation, power distribution modules of unregulated and regulated primary bus, and instrument power distribution modules.

  • PDF

Fuzzy Control of Discharge Pulse Duration for Electrical Discharge Machinery (방전가공기의 방전 펄스 시간의 퍼지제어)

  • Lee, Je-Hie;Park, Ho-Joon;Yang, Jik-Hyun;Huh, Uk-Youl;Lee, Sun-Woo;An, Sung-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1167-1169
    • /
    • 1996
  • As electrical discharge machinery(EDM) is industrial process which is manufactured by discharge energy, by producing discharge, EDM process finished material at the little micrometer air gap. Especially, EDM is used for the characteristic of heat-resisting material, it puts to use air-space industrial element, confusing shaping material such as jet engine, rocket elements. Working performance. is changed by environment of working, discharge current voltage and duration of discharge pulse. Evaluation of performance working is work speed, clearance smoothing of product surface, wasting of pole. In this paper, this machine is compensated by adaptive controller which corrects the weak points of classical machine which is observed and operated working condition by user in hands. The previous purpose is main object in this thesis. The adaptive controller automatically detect abnormal condition and working conditions. To improve performance, surface smoothing and working speed, the adaptive controller uses fuzzy control strategy. To evaluate performance, this controller is implemented by microprocessor i80c196 and is applied real experimental machine.

  • PDF

Image Analysis by CNN Technique for Maintenance of Porcelain Insulator (자기애자의 유지 관리를 위한 CNN 기법을 이용한 이미지 분석)

  • Choi, In-Hyuk;Shin, Koo-Yong;Koo, Ja-Bin;Son, Ju-Am;Lim, Dae-Yeon;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.239-244
    • /
    • 2020
  • This study examines the feasibility of the image deep learning method using convolution neural networks (CNNs) to maintain a porcelain insulator. Data augmentation is performed to prevent over-fitting, and the classification performance is evaluated by training the age, material, region, and pollution level of the insulator using image data in which the background and labelling are removed. Based on the results, it was difficult to predict the age, but it was possible to classify 76% of the materials, 60% of the pollution level, and more than 90% of the regions. From the results of this study, we identified the potential and limitations of the CNN classification for the four groups currently classified. However, it was possible to detect discoloration of the porcelain insulator resulting from physical, chemical, and climatic factors. Based on this, it will be possible to estimate the corrosion of the cap and discoloration of the porcelain caused by environmental deterioration, abnormal voltage, and lightning.

A Protection Circuit for the Power Supply of a Gas Discharge Lamp

  • Kim, Ho-Sung;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Jung, Hye-Man;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.777-783
    • /
    • 2010
  • In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency. To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.

A Study on Performance Enhancement of Distance Relaying by DC Offset Elimination Filter (직류옵셋제거필터에 의한 거리계전기법의 성능 개선에 관한 연구)

  • Lee, Kyung-Min;Park, Yu-Yeong;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • Distance relay is widely used for the protection of long transmission line. Most of distance relay used to calculate line impedance by measuring voltage and current using DFT. So if there is a computation error due to the influence of phasor by DC offset component, due to excessive vibration by measuring line impedance, overreach or underreach can be occurs, and then abnormal and non-operation of distance relay can be issue. It is very important to implement the robust distance relaying that is not affected by DC offset component. This paper describes an enhanced distance relaying based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any prior information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced distance relay uses fault current as well as residual current. The behavior of the proposed distance relaying using off-line simulation has been verified using data about several fault conditions generated by the ATP simulation software.