• Title/Summary/Keyword: AT-Cut Quartz Crystal

Search Result 21, Processing Time 0.026 seconds

A Study on the Identification Odorants using Six Channel Piezoelectric Crystals (6채널 압전소자를 이용한 냄새인식에 관한 연구)

  • 권영수;장상목;박옥순;최용성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.947-950
    • /
    • 1992
  • At-cut quartz crystal has been applied as chemical vapour sensors. The responses of quartz crystal at 9 MHz coated with phosphatidylglycerol(PG), phosphatidylinositol(PI), phosphatidylethanolamine(PE), phosphatidylserine(PS), and lipid A(LA) are determined for amyl acetate, acetoin, menthone and other organic gases which showed different affinities for each lipid. The identification of odorants depending on the species of lipid used for coating is discussed in terms of the normalized resonant frequency shift pattern.

  • PDF

Evaluation of Langmuir-Blodgett Ultra-thin Films by using a Quartz Crystal (수정진동자에 의한 LB초박막의 평가)

  • 최용성;박옥순;김철홍;장상목;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.39-41
    • /
    • 1992
  • The characteristics of LB ultra-thin film multi-layers were evaluated by the AT-cut quartz crystal. Cholesterol and phosphatidyl choline LB multi-layers were deposited on the surface of quartz crystal by using vertical lifting method and horizontal lifting method. There was good relationship between deposition ratio and frequency shift, and the frequency was more stable at the case of horizontal lifting method to the vertical lifting method.

  • PDF

Construction of Low Noise Electrochemical Quartz Crystal Microbalance

  • Hwang, Ui Jin;Im, Yeong Ran
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.1
    • /
    • pp.39-42
    • /
    • 1996
  • A new oscillator for electrochemical quartz crystal microbalance (EQCM) was developed by using an operational amplifier without any LC component. The home-made EQCM using this oscillator showed only 0.02 Hz frequency noise at 0.3 s gate time when a 6 MHz AT-cut crystal was used. Pb underpotential deposition on gold substrate in nitric acid media was examined to demonstrate the performance of this EQCM. The derivative of frequency change could be obtained without averaging multiple scans.

Electrochemical Determination of Glucose Concentration Contained in Salt Solution (소금용액에 포함된 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

The Response Characteristics of Organic Chemical Vapors by using Quartz Crystal Resonator (수정진동자에 의한 유기 가스의 응답 특성)

  • Choi, Yong-Sung;Shin, Hoon-Kyu;Chang, Sang-Mnok;Kwon, Young-Soo;Chang, Jeong-Soo;Bae, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.246-248
    • /
    • 1993
  • We investigated the responses of six types of lipid-coated AT-cut quartz crystal resonators to chemical vapour sensors. The responses of quartz crystal at 9 MHz coated with phosphatidylglycerol (PG), phosphatidylinositol(PI), phosphatidylethanolamine(PE), phosphatidylserine(PS), and lipid A(LA) were obtained for amyl acetate, acetoin, menthane and other organic gases which showed different affinities for each lipid. The identification of odorants depending on the species of lipid used for coating is discussed in terms of the normalized resonant frequency shift pattern.

  • PDF

Analysis of the characteristics of polymer multi-layers by using quartz crystals (수정진동자를 이용한 고분자 누적막의 특성분석)

  • Kim, Ki-Young;Kim, Jong-Min;Kwon, Young-Soo;Lee, Burm-Jong;Chang, Yong-Keun;Kim, Jong-Deuk;Chang, Sang-Mok
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.3-10
    • /
    • 1994
  • The use of preformed polymers and their cross-linking has been attempted in order to improve the intrinsic fragility of monolayers and Langmuir-Blodgett(LB) films. The evaluation of the characteristics of the LB multi-layer by using an AT-cut quartz crystal has been also attempted. This study reveals that the polyether pendants of 2C18VE3 lie at the air-water interface at low surface pressures and are forced down into the subphase when the monolayers are compressed. This characteristic behavoir of the pendant polyethers is very clear on aqueous poly allyl amine(PAA) and is also observeable on saturated aqueous NaCl and $CaCl_{2}$. And the characteristics of LB multi-layers could be evaluated by using AT-cut quartz crystal in situ.

  • PDF

Evaluation of the characteristics of polymer LB multi-layer (고분자 LB막의 누적 특성 평가)

  • Kim, Ki-Young;Kim, Chul-Hong;Shin, Hoon-Kyu;Chang, Sang-Mok;Kwon, Young-Soo;Lee, Bun-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1203-1205
    • /
    • 1993
  • The use of preformed polymers and their cross-linking have been attempted in order to improve the intrinsic fragility of monolayers and Langmuir-Blodgett(LB) films. The evaluation of the characteristics of LB multi-layer by using AT-cut quartz crystal have been also attempted. From this study, it reveals that the polyether pendants of 2C18VE3 lie at the air-water interface at low surface pressures and are forced down into the subphase when the monolayers are compressed. This caracteristic behavoir of the pendant polyethers is much clear on aqueous PAA and also observed on saturated aqueous NaCl. And the characteristics of LB multi-layers could be evaluated by using AT-cut quartz crystal in situ.

  • PDF

The development of AT-Cut Quartz Organic Vapor Recognizing System Using Artificial Neural Network (인공신경망을 이용한 수정진동자 유기용매 인식시스템의 개발)

  • Park, Soo-Heang;Ryu, Min-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • 8개의 수정진동자 위에 서로 다른 종류의 Lipid를 코팅하여서 만든 센서 배열을 가지고 유기용매를 인식할 수 있는 System을 구성한다. 유기용매 인식센서에 대한 수학적 모델을 사용하여 여러 가지 유기용매에 대한 센서의 응답으로부터 센서 표면과 유기용매 간의 물질 전달속도 패턴과 친화력 패턴을 얻어 유기용매 종류를 인식하였다. 패턴인식은 인공신경망을 이용하였으며 인공신경망의 연결 강도 수정은 Levenberg-Marquardt 알고리즘을 사용하였다. 신경망의 출력은 4개로 하였고, 디지털 신호인 0과 1의 조합으로 유기용매 종류를 구분하였다. 이 시스템을 이용하여 9개의 유기용매 Acetone, Benzene, Chloroform, Carbon-tetrachloride, Ethylacetate, Buthylacetate, Cyclohexane, Dichloromethane, 1,1,2,2,Tetrachloroethane, 2,2,4Trimethylpentane을 구분하여 인식할 수 있었다.

  • PDF

Gas Response and Electrical Properties of Organic Ultra-thin Films (유기 박막의 전기적 특성 및 가스 반응 특성)

  • 박재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.820-825
    • /
    • 1998
  • We deposited stearic acid LB films by using Langmuir-Blodgett (LB)method and investigated anisotropy electrical conduction characteristics by I-V measurement for horizontal direction and vertical direction. Also, we measured gad response between deposited LB films and organic gas for various temperature(0~8$0^{\circ}C$) by 9MHz At-cut quartz crystal microbalance. The LB films have electrical conduction characteristics such as semiconducting and insulating properties. The is, the conductivity of LB films for the horizontal and vertical direction is about 10\ulcornerS/cm and 10\ulcorners/cm, respectively. the frequency shift of stearic acid LB films for the organic gases depended on the mass change by the surface adsorption and the inner penetration to the sensing films. The resonant frequency shift of the quartz crystal microbalance for temperature properties of LB films is thought to the effect of the rearrangement or the damage pf LB films above the melting point and the mobility increasement of the organic gas by the temperature rising.

  • PDF

Electrochemical Determination of Glucose in Sea Water (해수 중 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.73.2-77
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the detennination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a QUartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution and the effect of the concentration is analyzed to find a proper relation between the concentration and the measurements. It is fOlmd that a linear relation between the concentration of less than 900 Dpm and the peak current when a constant potential of -180 m V vs. Ag/ AgCI reference is applied.

  • PDF