• Title/Summary/Keyword: ASTM

Search Result 1,205, Processing Time 0.029 seconds

A Review of Strength Estimation Method on Ulsan Sedimentary Rocks (울산지역 퇴적암의 강도 추정법 연구 - 점 하중 강도지수로 일축 압축강도 추정 -)

  • Min, Tuk-Ki;Moon, Jong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.63-72
    • /
    • 2006
  • In the ASTM and ISRM, an uniaxial compressive strength(${\sigma}_{c}$) has been estimated to be 23(ASTM) or $20{\sim}25$(ISRM) times of point load strength index using a diametral test regardless of the rock rating or geological conditions. This paper presents a relationship between $I_{s}$ and ${\sigma}_{c}$ of a weak sedimentary rocks on Ulsan of the Kyung-Sang Basin in Korea. In the results of 291 for ${\sigma}_{c}$ test and 2310 for $I_{s}$ test from 77 spots, the predicted errors of ${\sigma}_{c}$ determined by strength ratio of ${\sigma}_{c}/I_{s}$ have been relatively less than those determined by linear regression analysis. And in case of weak sedimentary rocks such as mudstones, shales and sandstones, ${\sigma}_{c}$ should be lower than those suggested by ISRM and ASTM.

Comparison Study on Efficacies of Disinfectants and Sanitizers Among Methods for Quantitative Surface Test (살균소독제의 정량적 표면시험방법별 유효성 비교)

  • Kim, Ae-Young;Kim, Yong-Su;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.238-244
    • /
    • 2010
  • Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.

Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test- (국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로-)

  • Kim, Dami;Lee, Inseong;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.5
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

Evaluation of Alkali-Silica Reactivity for Aggregates in Korea according to Test Methods (시험방법에 따른 국내 골재의 알칼리-실리카 반응성 평가)

  • Yun, Kyong-Ku;Kim, Seong-Kwon;Hong, Seung-Ho;Han, Seung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.689-696
    • /
    • 2008
  • The purpose of this study was to evaluate the alkali-silica reactivity for aggregates in Korea according to test methods: accelerated mortar bar test (AMBT) by ASTM C 1260; chemical test by KS F 2545 (ASTM C 289). The results are as follows: The AMBT (ASTM C 1260) results showed that two (2) igneous rocks (two mica granite and felsite), three (3) sedimentary rocks (arkose, red sandstone and shale), two (2) metamorphic rock (slate and vitric tuff), one (1) mineral (quartz) showed more expansion than 0.1% at 14 days. But, some sedimentary rocks and metamorphic rocks expanded more than 0.1% at 28 days even though they were less than 0.1% at 14 days. Therefore, it is necessary to extend the experimental dates more than 14 days to evaluate the possibility of alkali-aggregate reactivity. The chemical test (KS F 2545) results showed that five (5) igneous rocks (andesite, diabase, granite porphyry, muscovite granite and diorite) were indicative of potentially deleterious expansion, while two (2) igneous rocks (diorite porphyry and quartz porphyry) were possible indicative of expansion, and three (3) igneous rocks (biotite granite, two mica granite and felsite) were indicative of innocuous reactivity. The above results showed that the results from chemical method (KS F 2545) and AMBT (ASTM C 1260) had little relationship.

A Comparative Study on the Testing Methods for the Analysis of Tensile Strength of GERP Rebars (GFRP 보강근의 인장강도 분석을 위한 시험방법 비교 연구)

  • You, Young-Chan;Park, Ji-Sun;You, Young-Jun;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.303-312
    • /
    • 2006
  • The main objective of this experimental study is to examine the feasibilities of each testing method with various kinds of grip systems for the analysis of tensile strength of GFRP(glass fiber reinforced polymer) reinforcing bars. Three types of grip systems were examined such as resin-sleeved pipe-type grip proposed by CSA(Canadian Standard Association), frictional resistance type metal grip by ASTM(American Standard for Testing and Materials) and wedge-inserted cone-type grip normally used in prestressing tendons. Also, mechanical properties of GFRP rebars with different surface deformations were investigated for each different type of testing grip used in this study. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the CSA S806-02 recommendations. From the test results, it was found that the highest tensile strengths of GFRP rebars were observed when tested by resin-sleeved grip system regardless of their different surface deformations. But tensile strengths of GFRP rebars by ASTM grip system are only 10% less than those by CSA grip system. On the other hand, CSA grip is not only difficult to prepare but also not disposable. Therefore, ASTM grip system is recommended as a practical alternative to estimate the tensile strength of GFRP rebars.

Type 347 stainless steel 피로시험 데이터의 통계처리

  • Min, Gi-Deuk;Kim, Seon-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.35.2-35.2
    • /
    • 2009
  • 최근 전세계적으로 저탄소, 녹색성장으로 인하여 원자력발전이 주목받고 있다. 또한 에너지의 고효율로 인한 발전소의 설비가 대형화가 됨에 따라 발전소의 수명평가와 건전성평가가 중요해지고 있다. 일반적으로 구조물 내에 존재하는 균열의 크기와 형상을 파악하여 피로균열전파속도를 평가함으로써 건전성평가를 확인하고 있다. 그리고 고온, 고압에서의 피로균열전파속도는직류전위차 (Direct Current Potential Drop : DCPD)법을 사용하고 있다. DCPD법은 균열의 정밀한 측정방법으로써 측정시 오차가 발생하기 때문에 ASTM에서 제시된 incremental polynomial 법을 권고하고 있다. 따라서 본 연구에서는 피로균열전파전파속도의통계적처리를 통해서 합리적인 곡선을 구하여 건전성평가에 활용하고자 한다. 실험에 사용된 시편은 두께 5mm, 폭 25.4mm CT시편을 사용하였으며, 1mm의 예비균열을 주었다. 그리고 실험온도는 상온에서 실시 하였으며, 주파수는 10Hz를 주었다. 그리고 DCPD 측정을 위해 5A의 전류를 주었으며, 이때 측정된 전압값을 ASTM에 제시된 관계식에넣어 균열길이로 환산하였으며, 데이터처리는 ASTM에 제시된 incremental polynomial법을 기본적으로 사용하였다. 또한 ASTM에 제시된 2n+1을 이용하여 데이터의 수 n을 1~7 까지 변화를 주어 3~15 point 까지 데이터를 처리하여곡선을 제시하였다. 분석결과 $R^2$값이 1을 기준으로 했을 때 3~7 point 까지는큰 차이를 보이지 않았지만 9-point 이후부터는 $R^2$ 감소함을 알 수 있었다. 또한 적용된 데이터의수에 따라 피로군열전파속도 곡선에서 측정된 Paris law의 n값과 C 값은 큰차이를 보이지 않았다.

  • PDF

Prediction and Measurement of Flash Point and Fire Point of Aromatic Hydrocarbons (방향족탄화수소의 인화점과 연소점 측정 및 예측)

  • Ha Dong-Myeong;Han Jong-Geun
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.21-26
    • /
    • 2005
  • The flash points and the fire points are one of the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable substances. In this study, the flash points of aromatic hydrocarbons, were measured by using Pensky-Martens Closed Cup apparatus(ASTM-D93) and Tag Open-Cup apparatus(ASTM D 1310-86). Also the fire points of aromatic hydrocarbons, were measured by using Tag Open-Cup apparatus. The measured flash points were in good agreement with reference values. The measured fire points compared with the estimated values based on 1.23 times stoichiometric concentration. The values calculated by the proposed equation were in agreement with measured values.

  • PDF

An Experimental Study on the Alkali-Silica Reaction of Crushed Stones (쇄석 골재의 알칼리-실리카 반응에 관한 실험적 연구)

  • 윤재환;정재동;이영수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.108-117
    • /
    • 1994
  • This study was performed to investigate the Alkali-Silica Reaction(ASR) of crushed stones using chemical analysis, polarization microscope, XRD, chemical method(KS F 2545, ASTM C 289), mortar-bar method( KS F 2546, ASTM C 227) and Scanning Electron Microscope (SEM ) and Energy Dispersive X-ray Analysis(EDXA) of reaction products by ASK in the mortar bars and to investigate the influence on alkali content and kind of added alkali to the ASR. Test results show that one kind of domestic crushed stone is estimated as deleterious by ASTM chemical method and mortar bar method, and reaction product is proved as alkali silicate gel by EDXA.

An Exploratory Study on Domestic and International Protective Clothing Standard - Focused on ISO, ASTM, CEN, KS - (보호복 관련 국내·외 표준에 대한 탐색적 조사 - ISO, ASTM, CEN, KS를 중심으로 -)

  • Han, Sul-Ah;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.10 no.1
    • /
    • pp.92-100
    • /
    • 2008
  • When designing protective clothing, there are something to be considered such as physiological feature of human body, acting range not to restrict physical activity, and effectiveness of material. Because the primary objective of protective clothing is to protect human body from danger and it is designed through complex designing process not likely general clothing design. However, current evaluation techniques-such as the ISO, the ASTM and the CEN, and KS-provide only the standard to evaluate the primary feature of material (testing, performance requirements, material specification, selection and application, test and care, and so on). There are no standard to evaluate influence for the human body while protective clothing put on. Especially, in Korea, there is KS to evaluate protective clothing, but it is partially translated version from ISO because of lack of core technology about this field. However, developed countries recognize it is new competitive means in the time of Global Standards and they are competing to make their own standard to global standard for the protective clothing. Therefore, it can be great opportunity for Korean clothing and textile industry to revitalize if focusing on research and development for protective clothing design based on physical activity of human body, fit evaluation technique and sizing which is currently no global standard for it and developing our standard to global standard.

Analysis of biodiesel quality based on infrared spectroscopy and multivariate statistics (적외선 분광분석과 다변량 통계에 기반한 바이오디젤 품질분석)

  • Kim, Hye-Sil;Cho, Hyun-Woo;Liu, J. Jay
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.214-222
    • /
    • 2012
  • ASTM (American Society for Testing and Materials) D6751-10 suggests analytical methods as well as specifications for biodiesel quality. However, it is expensive and time-consuming to follow the ASTM testing methods to analyze biodiesel and various impurities. This paper develops a quantitative analysis system for biodiesel and impurities based on Infrared spectroscopy and a multivariate statistical method, PLS (partial least squares). In addition, four different pre-processing techniques were compared for spectrum correction and noise reduction. Savitzky-Golay pre-processing showed the best performance.