• 제목/요약/키워드: AS wire

검색결과 3,140건 처리시간 0.028초

고압 전력 케이블에서의 흰개미 피해 방지 대책에 관한 고찰 (Study of termite damage to high voltage power cable and its prevention)

  • 김종원;김정준;최봉남;전문식;강도길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1643-1645
    • /
    • 1994
  • It has been reported frequently that damage to underground electric power cable was brought about, due to attack by Insect such as termite (white-ant) and by rodent such as rat, in tropical and semitropical areas. Among these cable damages, we are likely to describe the damage to cable by termites as causing the severe trouble in cable operation and to solve this trouble with termite-proof method regarded as the most effective and economical one. This report covers our experiences of manufacturing the cable for anti-termite purpose and its intrinsic properties in cable operation.

  • PDF

Rehabilitation of exterior RC beam-column connections using epoxy resin injection and galvanized steel wire mesh

  • Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.253-263
    • /
    • 2019
  • The efficacy of a galvanized steel wire mesh (GSWM) as an alternative material for the rehabilitation of RC beam-column connections damaged due to reversed cyclic loading was investigated. The repair mainly uses epoxy resin infused under pressure into the damaged zone and then confined using three types of locally available GSWM mesh. The mesh types used herein are (a) Weave type square mesh with 2mm grid opening (GWSM-1) (b) Twisted wire mesh with hexagonal opening of 15 mm (GSWM-2) and (c) welded wire mesh with square opening of 25 mm (GSWM-3). A reduced scale RC beam-column connection detailed as per ductile detailing codes of Indian Standard was considered for the experimental investigation. The rehabilitated specimens were also subjected to similar cyclic displacement. Important parameters related to seismic capacity such as strength, stiffness degradation, energy dissipation, and ductility were evaluated. The rehabilitated connections exhibited equal or better performance and hence the adopted rehabilitation strategies could be considered as satisfactory. Confinement of damaged region using GSWM-1 significantly enhanced the seismic capacity of the connections.

폴리머 코팅된 NiTi합금 교정선의 표면특성 (Surface Characteristics of Polymer Coated NiTi Alloy Wire for Orthodontics)

  • 조주영;김원기;최환석;이호종;최한철
    • 한국표면공학회지
    • /
    • 제43권3호
    • /
    • pp.132-141
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate surface characteristics of polymer coated NiTi alloy wire for orthodontics using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with field emission scanning electron microscopy(FE-SEM), energy dispersive x-ray spectroscopy(EDS) and atomic force microscopy(AFM). The phase transformation of non-coated NiTi wire from martensite to austenite occurred at the range of $14{\sim}15^{\circ}C$, in the case of coated wire, it occurred at the range of $16{\sim}18^{\circ}C$. Polymer coating on NiTi wire surface decreased the surface defects such as scratch which was formed at severe machined surface. From the AFM results, the average surface roughness of non-coated and coated NiTi wire was 13.1 nm, and 224.5 nm, respectively. From convetional surface roughness test, the average surface roughness of non-coated and coated NiTi wire was $0.046{\mu}m$, and $0.718{\mu}m$, respectively.

국내 거주환경에서의 전자기장 노출평가를 위한 Wire code의 타당성에 관한 연구 (Application of a Wire code in Domestic Residential EMF Studies)

  • 탁상우;김현;김록호
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.55-60
    • /
    • 2000
  • Wire codes, introduced by Wertheimer and Leeper, are interesting largely because several case-control studies have reported associations between them and certain types of cancers, including childhood leukemia. This paper is concerned with the reliability of wire codes as a surrogate for residential electric and magnetic field, divided into four categories based on the electrical wiring within 40m of homes. To examine the correlation between spot measurements and wire codes, EMF was measured by using HI-3604 and classified by wire codes. The correlation between long-transformed RMS of magnetic field and wire codes was 0.81. But the correlation between log-transformed RMS of electric field and wire codes was 0.27. The results led us to determine a four category from of the Wertheimer and Leeper code that 1) may be useful in domestic epidemiological studies and 2) is not suitable for electric field exposure. Thus, the critical point of exposure assessment in residential magnetic field is to classify a wire code precisely.

  • PDF

플러그 내부에서 발생된 소선 단선에 의한 발열특성 (The Thermal Characteristics of Partially Disconnected Wire Happened in Plug)

  • 지승욱;김시국;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

습식 다단 인발공정 해석 프로그램 개발 밀 적용 (Development of Analysis Program for Multi-Pass Wet Wire Drawing Process and Its Application)

  • 이상곤;김민안;김병민;조형호
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.126-134
    • /
    • 2003
  • This paper investigates the multi-pass wet wire drawing process considering the slip between the wire and the capstan. The production of fine wire through multi-pass wet wire drawing process would be impossible without backtension. The backtension is affected by many process parameters, such as slip, dies reduction, coiling number of wire at the capstan, machine reduction, characteristic of lubricant etc. Up to date, die design and dies pass schedule of multi-pass wet wire drawing process have been performed by trial and error of expert in the industrial field. In this study, an analysis program which can perform the analysis and considering the effect of slip at each capstan was developed. The effects of many important parameters (drawing force, backtension force, needed power, slip rate, slip velocity rate etc.) on multi-pass wet wire drawing process can be predicted by this developed program. It is possible to obtain the important basic data which can be used in the pass schedule of multi-pass wet wire drawing process by using this developed program.

열적 스트레스 변화에 따른 600V 비닐절연전선의 특성 분석 (The Properties Analysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.108-115
    • /
    • 2001
  • 본 연구에서는 600V 비닐절연전선에 열적 스트레스를 인가하였을 때 전선의 특성 변화를 분석하였다. 전선의 구조 분석에서 정상 전선은 표면에 방향성을 갖고 있으나, $400^{\circ}c$ 이상에서 열화된 전선의 경우 탄화물, 크랙, 결정 등이 형성되었다. 정상 전선의 표면 조성은 Cu ; 100%였으나, $800^{\circ}c$에서 열화된 전선의 단면 조성은 Cu : 78.89%, O : 21.11%를 나타냈다. 연동선의 시차주사열량 분석 결과 $700^{\circ}c$ 이상에서 열화된 전선에서 새로운 반응 피크가 관측되었다. 절연물의 시차열 분석에서 $150^{\circ}c$로 열화된 전선의 경우 정상 전선의 반응점보다 낮은 $264^{\circ}c$에서 흡열 반응이 나타났다. 등선의 열화에 따른 산소 점유율은 $500^{\circ}c$에서 약 20%이다.

  • PDF

방전 가공기용 복합재료 외팔보의 제작 및 성능평가 (Manufacture and performance test of the composite cantilever arm for electrical discharge wire cutting machine)

  • 최진호
    • Composites Research
    • /
    • 제13권6호
    • /
    • pp.39-46
    • /
    • 2000
  • 방전가공은 공구와 공작물 사이의 얇은 간극에 전류를 방전시켜 금속을 가공하는 방법이다. 방전 와이어 가공은 전도성 와이어를 사용하는 방전가공의 특수한 예로서, 펀치나 금형제조에 널리 이용되고 있다. 와이어 방전가공에서 와이어는 와이어 가이드 및 외팔보로서 지지되어 있다. 최근 생산성의 증가추세와 더불어 와이어의 이송속도가 증가함에 따라 외팔보의 진동 등으로 인한 기계 정밀도의 저하가 우려된다. 본 논문에서는 정, 동특성이 우수한 방전가공기용 복합재료 외팔보를 설계, 제작하였다. 끼워맞춤길이와 보강 적층수의 변화에 따른 정, 동특성의 변화를 살펴보기 위하여 시편을 제작하여 하중실험을 수행하였다. 또한 유한요소 해석을 수행하여 하중실험의 결과와 상호 비교하였다. 시편실험의 결과로부터 방전가공기용 복합재료 외팔보를 설계, 제작하여 기존의 금속 외팔보와 그 성능을 상호 비교하였다.

  • PDF

Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발 (Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors)

  • 김성덕
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.33-41
    • /
    • 2001
  • 와이어 로프는 무거운 중량을 안전하게 운반하거나 기계적인 에너지를 빠르게 전송하는 곳과 같은 산업응용 분야에 광범위하게 사용되어 왔다. 특히, 운전 중 엘리베이터의 와이어 로프가 파손되면 큰 재산 상 손실과 주변 인명의 심각한 상해를 초래할 수 있다. 따라서, 와이어 로프의 정기적인 검사는 매우 중요하다. 와이어 로프의 고장 검출은 로프의 구조, 특성, 결함 특성, 검출방법과 신호처리 방법에 대한 기본적인 이해가 요구된다. 이 연구에서는 엘리베이터에 노화된 와이어 로프에 대한 마모, 단선, 부식과 형붕괴와 같은 결함을 검출하기 위하여, Hall 센서를 결합한 새로운 결함 검출시스템의 개발에 대하여 다룬다. 휴대용 계측기로서 검출기를 사용하기 위하여, Hall 센서를 가진 센싱 부분과 아날로그 신호처리 및 프로그램의 제작에 대한 몇 가지 특성들이 서술되었다. 제작된 검출시스템에 대한 실험과 실장시험 결과 역시 제시되었다. 그 결과, 검출시스템은 사용 중인 노화된 와이어 로프의 결함을 검출하는데 양호한 효율성을 갖는다는 것을 확인하였다.

  • PDF

고지재생연구(제 9보)-국산 골판지 고지 내의 미세분 및 이물질들이 Condebelt Press Drying System에 미치는 영향- (Recycling of Wastepaper(IX)-Effects of KOCC Fines and Other Contamination on Condebelt Press Drying System-)

  • 지경락;류정용;신종호;송봉근
    • 펄프종이기술
    • /
    • 제32권1호
    • /
    • pp.19-25
    • /
    • 2000
  • In Condebelt press drying system, the temperature difference between top and bottom plate of Condebelt transfers water to bottom side, Fine fibers, stickies , ink , and various inorganic materials are also migrated to the fine wire located at the bottom plate by highly pressurized moisture flow. As a result, the fine wire contaminated by plugging of these fine and sticky materials can cause many problems such as blistering or partial crushing of paper. The contaimination of fine wire leads to a deterioroated strength together with uneven physical properties of paper. In this paper, froth-flotatiion method, which is commonly used in the field of ONP recycling process, were adopted to separate the contaminants in KOCC as a new fiber fractionation method. Standard deviation of paper strength and brighteness decreased of Condebelt fine wire were measured to investigate the effect of contaminants removal . The standard deviations of paper strength obtained from the flotated accept were not dependent on the number of condebelt press drying . However, in the case of untreated KOCC, the standard deviations were increased as press drying repeated. This indicates that the contaminant gives uneven physical properties to the paper by wire plugging . Optical and SEM images clearly illustrate the effect of contaminants on the wire condition.

  • PDF