• Title/Summary/Keyword: AR Mode

Search Result 150, Processing Time 0.024 seconds

A Study on Fabrication of ZnO Surface Acoustic Wave Filter for Communication Devices (통신기기용 ZnO 탄성표면파 필터의 제작에 관한 연구)

  • Lee, Dong-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.393-394
    • /
    • 2007
  • In this study, to minimize the above effect Zinc Oxide(ZnO) thin films on Si(100) substrate were deposited by RF magnetron sputter with changing sputtering conditions such as Ar/$O_2$ gas ratios, RF power, substrate temperature, chamber prsssure and target-substrate distance. To analyze a crystallographic properties of the films, ${\Theta}/2{\Theta}$ mode X-ray diffraction, rocking curve and Alpha-step were performed. SAW filters were fabricated to evaluate the feasibility of ZnO thin film as a piezoelectrical materials and the processes of ZnO SAW filters using etch and lift-off were compared.

  • PDF

Fabrication and Lasing Characteristics of Nd Doped Fiber Laser (Nd 첨가 광섬유 레이저 제작 및 발진특성)

  • 이상배;조재철;김선호;김상국;최상삼;김병윤;김영덕
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.178-184
    • /
    • 1990
  • The fiber laser was fabricated using Nd doped single mode fiber. The fiber was made by MCVD and solution doping method, and the Fabry-Perot resonator was composed with two dichroic mirrors. It was operated at 1.096 um with 15 nm bandwidth. When the reflectivity of the output copuling mirror was 67.5%. the maxiurn output power 1.88 mw and its slope efficiency 1.28%. was obtained.

  • PDF

Vibrational Assignment of S$_8$ from Normal Coordinatie Analysis

  • Chang, Man-Chai;Kim, Hyun-Yong;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.1
    • /
    • pp.29-32
    • /
    • 1985
  • Normal modes of crystalline orthorhombic sulfur belonging to the space group $D_{2h}$-Fddd, have been evaluated by taking the lowest temperature phase in the solid. Normal modes are obtained by the valence force field with modified force constants and a quantitative description of the mode is adjusted by the potential energy distribution. Since the full crystal system of orthorhombic sulfur is so large, we intended to calculate the normal modes simply by constructing the imaginary box made by the infinite mass boundary. And the Raman experiment is done by using the more powerful Ar-Kr gas laser with lowering the temperature to ${\sim}10^{\circ}K$.

Study on the Relationship between Concentration of JGB and Current Density in TSV Copper filling (TSV 구리 필링 공정에서 JGB의 농도와 전류밀도의 상관 관계에 관한 연구)

  • Jang, Se-Hyun;Choi, Kwang-Seong;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.99-104
    • /
    • 2015
  • The requirement for success of via filling is its ability to fill via holes completely without producing voids or seams. Defect free via filling was obtained by optimizing plating conditions such as current mode, current density and additives. However, byproducts stemming from the breakdown of these organic additives reduce the lifetime of the devices and plating solutions. In this study, the relationship between JGB and current density on the copper via filling was investigated without the addition of other additives to minimize the contamination of copper via. AR 4 with $15{\mu}m$ diameter via were used for this study. The pulse current was used for the electroplating of copper and the current densities were varied from 10 to $20mA/cm^2$ and the concentrations of JGB were varied from 0 to 25 ppm. The map for the JGB concentration and current density was developed. And the optimum conditions for the AR 4 via filling with $15{\mu}m$ diameter were obtained.

Limb-girdle Muscular Dystrophy (지대형 근이양증)

  • Kim, Dae-Seong
    • Annals of Clinical Neurophysiology
    • /
    • v.6 no.2
    • /
    • pp.65-74
    • /
    • 2004
  • Limb-girdle muscular dystrophy (LGMD) is a heterogeneous group of inherited muscle disorders caused by the mutations of different genes encoding muscle proteins. In the past, when the molecular diagnostic techniques were not available, the subtypes of muscular dystrophies were classified by the pattern of muscle weakness and the mode of inheritance, and LGMD had been considered as a 'waste basket' of muscular dystrophy because many unrelated heterogeneous cases with 'limb-girdle' weakness were put into the category of LGMD. With the advent of molecular genetics at the end of the last century, it has been known that there are many subtypes of LGMD caused by the mutation of different genes, and now, LGMD is classified according to the results of the linkage analysis and the genes or proteins affected. Only small proportion (probably less than 10%) of LGMD is dominantly inherited, and autosomal dominant LGMD (AD-LGMD) consists of six subtypes (LGMD1A to 1F) so far. In autosomal recessive LGMD (AR-LGMD), more than 10 subtypes (LGMD2A to 2J) have been linked and most of the causative genes have been identified. Among AR-LGMDs, LGMD2A (calpain 3 deficiency), 2B (dysferlin deficiency), and sarcoglycanopathy (LGMD2C-2F) are major subtypes. The defective proteins in LGMDs are components of nuclear envelope, cytosol, sarcomere, or sarcolemma, and seem to play a different role in the pathogenesis of muscular dystrophy. It is notable that many causative genes of LGMDs are also responsible for other categories of muscular dystrophy or diseases affecting other tissue. However, by which mechanism they produce such a broad phenotypic variability is still unknown. The identification of mutation in the relevant gene is confirmative for the diagnosis, and is essential for genetic counseling and antenatal diagnosis of LGMD. Because many different genes are responsible for LGMD, differentiation of subtypes using immunohistochemistry and western blotting is the essential step toward the detection of mutation. For the effective research and medical care of the patients with muscular dystrophy in Korea, a research center with a medical facility supported by the government seems to be needed.

  • PDF

A Study on a Statistical Modeling of 3-Dimensional MPEG Data and Smoothing Method by a Periodic Mean Value (3차원 동영상 데이터의 통계적 모델링과 주기적 평균값에 의한 Smoothing 방법에 관한 연구)

  • Kim, Duck-Sung;Kim, Tae-Hyung;Rhee, Byung-Ho
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.6
    • /
    • pp.87-95
    • /
    • 1999
  • We propose a simulation model of 3-dimensional MPEG data over Asynchronous transfer Mode(ATM) networks. The model is based on a slice level and is named to Projected Vector Autoregressive(PVAR) model. The PVAR model is modeled using the Autoregressive(AR) model in order to meet the autocorrelation condition and fit the histogram, and maps real data by a projection function. For the projection function, we use the Cumulative Distribution Probability Function (CDPF), and the procedure is performed at each slice level. Our proposed model shows good performance in meeting the autocorrelation condition and fitting the histogram, and is found important in analyzing the performance of networks. In addiotion, we apply a smoothing method by which a periodic mean value. In general. the Quality of Service(QoS) depends on the Cell Loss Rate(CLR), which is related to the cell loss and a maximum delay in a buffer. Hence the proposed smoothing method can be used to improve the QoS.

  • PDF

Assisted GNSS Positioning for Urban Navigation Based on Receiver Clock Bias Estimation and Prediction Using Improved ARMA Model

  • Xia, Linyuan;Mok, Esmond
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.395-400
    • /
    • 2006
  • Among the various error sources in positioning and navigation, the paper focuses on the modeling and prediction of receiver clock bias and then tries to achieve positioning based on simulated and predicted clock bias. With the SA off, it is possible to model receiver clock bias more accurately. We selected several types of GNSS receivers for test using ARMA model. To facilitate prediction with short and limited sample pseudorange observations, AR and ARMA are compared, and the improved AR model is presented to model and predict receiver clock bias based on previous solutions. Our work extends to clock bias prediction and positioning based on predicted clock bias using only 3 satellites that is usually the case under urban canyon situation. In contrast to previous experiences, we find that a receiver clock bias can be well modeled using adopted ARMA model. Test has been done on various types of GNSS receivers to show the validation of developed model. To further develop this work, we compare solution conditions in terms of DOP values when point positioning is conducted using 3 satellites to simulate urban positioning environment. When condition allows, height component is derived from other ways and can be set as known values. Given this condition, location is possible using less than 2 GNSS satellites with fixed height. Solution condition is also discussed for this background using mode of constrained positioning. We finally suggest an effective predictive time span based on our test exploration under varied conditions.

  • PDF

Design and operational characteristics of cw and KLM Ti : sapphire lasers with a symmetric Z-type cavity configuration (Z-형태의 대칭형 레이저 공진기 구조를 갖는 연속 발진 및 Kerr-렌즈 모드-록킹되는 티타늄 사파이어 레이저의 설계와 동작 특성)

  • Choo, Han-Tae;Ahn, Bum-Soo;Kim, Gyu-Ug;Lee, Tae-Dong;Yoon, Byoung-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.347-355
    • /
    • 2002
  • We have constructed a high efficiency and broad tunable cw Ti:sapphire laser with a four-mirror symmetric Z-type laser cavity to increase the laser usability. From theoretical analyses and experimental data for a symmetric Z-type laser cavity containing a Kerr medium, the cavity mode size and the Kerr-lens mode-locking (KLM) strength for KLM lasers can be confirmed as function of the position in the cavity, the intracavity laser power, and the stability parameter. As a result, the slope efficiency and the maximum average output power of cw Ti:sapphire laser at 5 W pumping power of Ar-ion laser were 31.3% and 1420 ㎽ respectively. The tunablility was ranged from 730 ㎚ to 908 ㎚ with average output power above 700 ㎽. We obtained the KLM operation easily by self-aperturing effect in the Kerr medium and the slope efficiency and the maximum average output power of KLM Ti:sapphire laser was 16% and 550 ㎽ respectively. The spectral bandwidth was 33 ㎚ at the center wavelength of 807 ㎚ and the pulse width was 27 fs with a repetition rate of 82 ㎒.

Water Supply forecast Using Multiple ARMA Model Based on the Analysis of Water Consumption Mode with Wavelet Transform. (Wavelet Transform을 이용한 물수요량의 특성분석 및 다원 ARMA모형을 통한 물수요량예측)

  • Jo, Yong-Jun;Kim, Jong-Mun
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.317-326
    • /
    • 1998
  • Water consumption characteristics on the northern part of Seoul were analyzed using wavelet transform with a base function of Coiflets 5. It turns out that long term evolution mode detected at 212 scale in 1995 was in a shape of hyperbolic tangent over the entire period due to the development of Sanggae resident site. Furthermore, there was seasonal water demand having something to do with economic cycle which reached its peak at the ends of June and December. The amount of this additional consumption was about $1,700\;\textrm{cm}^3/hr$ on June and $500\;\textrm{cm}^3/hr$ on December. It was also shown that the periods of energy containing sinusoidal component were 3.13 day, 33.33 hr, 23.98 hr and 12 hr, respectively, and the amplitude of 23.98 hr component was the most humongous. The components of relatively short frequency detected at $2^i$[i = 1,2,…12] scale were following Gaussian PDF. The most reliable predictive models are multiple AR[32,16,23] and ARMA[20, 16, 10, 23] which the input of temperature from the view point of minimized predictive error, mutual independence or residuals and the availableness of reliable meteorological data. The predicted values of water supply were quite consistent with the measured data which cast a possibility of the deployment of the predictive model developed in this study for the optimal management of water supply facilities.

  • PDF

Frequency Doubling in LiIO3 Crystals by the Ring Enhancement Cavity (고리형 증폭 공진기에 의한 LiIO3결정에서 제2조화파 발생)

  • Kim, Sang-Gee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.45-49
    • /
    • 1999
  • The second harmonic, wavelength is 397nm, of the continuous wave diode laser, whose maximum power is 35mW, was generated in $LiIO_3$ crystals in a ring enhancement cavity. 5mm- and 10mm-long crystals cut $43.21^{\circ}$ for optic axis were used in this experiment. Both surfaces of those were anti-reflection coated for 794nm. In case the crystal was inserted into the cavity, the condition of separation between two concave mirrors for the optimum mode matching was found. The conversion efficiency of second harmonic generation was increased by the resonant enhancement of pumping power in the ring enhancement cavity, and the frequency of diode laser was locked to that of the counter-propagation mode generated from the surface of crystal. When the pumping power was 28 mW, the infrared buildup factor was about 45 without the crystal, and 14 with the crystal due to the transmission loss of crystal. The maximum second harmonic powers of $1.5{\mu}W$ and $6.6{\mu}W$ were obtained, and corresponding conversion efficiencies were $(6.584{\pm}0.56){\times}10^{-3}$%, $2.6{\pm}0.21){\times}10%{-2}$% in 5mm- and 10mm-long $LiIO_3$, respectively.

  • PDF