• Title/Summary/Keyword: APEX

Search Result 1,136, Processing Time 0.035 seconds

APEX-1 Regulates Cell Proliferation through GDNF/GFRα1 Signaling (APEX-1은 GDNF/GFRα1 시그널을 통해 세포증식을 조절한다)

  • Kim, Hong-Beum;Hariharasudhan, Gurusamy;Youn, Cha-Kyung
    • Journal of Life Science
    • /
    • v.23 no.10
    • /
    • pp.1183-1191
    • /
    • 2013
  • Human apurinic/apyrimidinic endonuclease (APEX-1) is a multifunctional protein that is capable of repairing abasic sites and single-strand breaks in damaged DNA. In addition, it serves as a redox-modifying factor for a number of transcription factors. Identifying the transcriptional targets of APEX-1 is essential for understanding how it affects various cellular outcomes. Expression array analysis was used to identify glial cell-derived neurotropic factor receptor ${\alpha}1$ ($GFR{\alpha}1$), which is an encoding receptor for the glial cell-derived neurotropic factor (GDNF) family, the expression of which is induced by APEX-1. A target of GDNF/$GFR{\alpha}$ signaling, c-Src (Tyr418) was strongly phosphorylated by GNDF in the APEX-1 expressing cells. Moreover, GDNF initiated cell proliferation, measured by counting the number of cells, in the APEX-1 expressing cells. Importantly, the down-regulation of APEX-1 by siRNA caused a marked reduction in the $GFR{\alpha}1$ expression level, and it reduced the ability of GDNF to phosphorylate c-Src (Tyr418) and stimulate cell proliferation. These results demonstrate an association between APEX-1 and GDNF/$GFR{\alpha}$ signaling and suggest a potential molecular mechanism for the involvement of APEX-1 in cell survival and proliferation.

Evaluation of APEX model parameter uncertainty for runoff (유출에 대한 APEX 모형 매개변수 불확실성 평가)

  • Choo, Innkyo;Seong, Yeonjeong;Park, Jeongwoong;Jung, Younghun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.188-188
    • /
    • 2021
  • APEX(Agricultural Policy Enviromental eXtender) 모형은 일 단위로 구동되며 필지단위 및 소유역 단위에서의 흐름을 장기 모의를 할 수 있는 모형이다. APEX는 유출을 포함한 토양 침식, 탄소 이동 등 다양한 자연현상을 모의할 수 있는 모형이다. 강우에 의한 직접유출량을 APEX를 이용하여 산정할 수 있지만, 모델링 과정에서 발생하는 불확실성으로 인하여 부정적인 요인이 발생한다. 따라서 본 연구에서는 APEX 모형의 유출 매개변수를 이용한 불확실성을 평가하고자 한다. 이를 위해서 금강권역에서 표준유역으로 분류되어있는 한천 유역에 대해 2008~2019년도 유출량을 모의하였으며, 검증을 위해 동일기간에 대해 기저유출분리를 수행하였다. 불확실성 평가를 위해서 Python 기반으로 사전분포로부터 매개변수를 임의로 선택하도록 설정하여 총 10,000번의 구동을 수행하였다. 불확실성 평가지표로는 NSE, PBIAS, RSR을 이용하여 평가하여 평가지표별 불확실성 구간을 비교분석 하였다. 본 연구에서의 APEX 모형의 불확실성 평가를 통하여 APEX의 활용성을 더욱 확대하고 신뢰성을 높일 것으로 기대한다.

  • PDF

Nutrient canals on mandibular anterior region in cone beam computed tomography (Cone beam형 전산화 단층영상을 이용한 하악전치부 영양관의 연구)

  • Kang Jung-Ho;Kim Gyu-Tae;Choi Yong-Suk;Hwang Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.137-143
    • /
    • 2006
  • Purpose : To evaluate location, distribution, diameter, and length of the nutrient canals on mandibular anterior region using a cone beam computed tomography (CBCT). Materials and Methods : Mandibular CBCT was performed on 33 adults (18 males and 15 females) with no history of systemic disease, and any other dental surgery history Location, distribution, diameter, and length of the nutrient canals on mandibular anterior region were radiographically evaluated. A statistical comparison was done by SPSS. Results : In the location and distribution of nutrient canals, they were found in 6.8% at labial portion above root apex, in 93.28% at lingual portion above root apex in 46.2% at labial portion below root apex, and in 53.6% at lingual portion below root apex. Nutrient canals at lingual portion above root apex were most frequently observed between central and lateral incisors, and those at labial and lingual portion below root apex were most frequently observed between central incisors. The mean diameters of nutrient canals were 0.54 mm at labial portion above root apex, 0.61 mm at lingual portion above root apex, 0.66 mm at labial portion below root apex, and 0.76 mm at lingual portion below root apex. The mean lengths of nutrient canals were 2.63 mm at labial portion above root apex, 3.74 mm at lingual portion above root apex, 4.51 mm at labial portion below root apex, and 6.77 mm at lingual portion below root apex. Conclusion : CBCT is useful device to evaluate the anatomical structure of nutrient canals on mandibular anterior region.

  • PDF

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.

Evaluating the Performance of APEX-Paddy Model using the Monitoring Data of Paddy Fields in Iksan, South Korea (국내 논필지 모니터링 자료를 이용한 APEX-Paddy 모델 적용성 평가)

  • Kamruzzaman, Mohammad;Cho, Jaepil;Choi, Soon-Kun;Song, Jung-Hun;Song, Inhong;Hwang, Syewoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.1-16
    • /
    • 2020
  • The APEX model has been developed for assessing agricultural management efforts and their effects on soil and water at the field scale as well as more complex multi-subarea landscapes, whole farms, and watersheds. Recently, a key component of APEX application, named APEX-Paddy, has been modified for simulating water quality by considering paddy rice management practices. In this study, the performance of the APEX-Paddy model was evaluated using field data at Iksan experimental paddy sites in Korea. The discharge and pollutant load data during 2013 and 2014 were used to both manually and automatically calibrate the model. The APEX auto-calibration tool (APEX-CUTE 4.1) was used for model calibration and sensitivity analysis. Results indicate that APEX-Paddy reasonably performs in predicting runoff discharge rate and nitrogen yield. However, sediment and phosphorus yield is not correctly predicted due to the limitation of model schemes. With APEX-Paddy, the performance in reproducing the discharge and nitrogen yield is found to be a satisfactory level after manual calibration. The manually calibrated model performed better than the automatically calibrated model in nearly all comparisons. For runoff, manual calibration reduced PBIAS while R2 and NSE values of the automatically calibrated model were the same as the manual calibration. For T-N, NSE and PBIAS were reduced when using manual calibration, whereas R2 value was the same as manual calibration. The limitation of the APEX-Paddy model for predicting sediment, as well as the phosphorous yield, was discussed in this study.

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

A STUDY ON THE MECHANISM BY WHICH THE FREQUENCY-DEPENDENT APEX LOCATOR DETECTS THE APEX OF THE ROOT IN MOIST CANALS (주파수의존 근관장 측정기가 습윤한 근관내에서 근첨을 인지하게 되는 원리에 관한 연구)

  • Park, Han-Soo;Yoo, Hyeon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.676-681
    • /
    • 1998
  • The purpose of this study is to explain theoretically the mechanism of the frequency-dependent apex locator which can detect the apex of the root in moist canals with blood or other conductible canal irrigants. The frequency-dependent apex locator is based on measuring the ratio of the two impedances of the two alternating currents with different frequencies. We analyzed the changes of the ratio between the two impedances by using differential calculus. Our analysis shows that : 1. When the file is in the moist canal, the ratio between the two impedances is almost constant. 2. As the file approaches the apex of the root, the ratio decreases sharply. By this mechanism, the frequency-dependent apex locator can detect the apex of the-root quite accurately in moist canals.

  • PDF

Proximity of the mandibular molar root apex from the buccal bone surface: a cone-beam computed tomographic study

  • Kim, Dokyung;Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the proximity of the mandibular molar apex to the buccal bone surface in order to provide anatomic information for apical surgery. Materials and Methods: Cone-beam computed tomography (CBCT) images of 127 mandibular first molars and 153 mandibular second molars were analyzed from 160 patients' records. The distance was measured from the buccal bone surface to the root apex and the apical 3.0 mm on the cross-sectional view of CBCT. Results: The second molar apex and apical 3 mm were located significantly deeper relative to the buccal bone surface compared with the first molar (p < 0.01). For the mandibular second molars, the distance from the buccal bone surface to the root apex was significantly shorter in patients over 70 years of age (p < 0.05). Furthermore, this distance was significantly shorter when the first molar was missing compared to nonmissing cases (p < 0.05). For the mandibular first molars, the distance to the distal root apex of one distal-rooted tooth was significantly greater than the distance to the disto-buccal root apex (p < 0.01). In mandibular second molar, the distance to the apex of C-shaped roots was significantly greater than the distance to the mesial root apex of non-C-shaped roots (p < 0.01). Conclusions: For apical surgery in mandibular molars, the distance from the buccal bone surface to the apex and apical 3 mm is significantly affected by the location, patient age, an adjacent missing anterior tooth, and root configuration.

Control of Delta-Wing Vortex by Apex Strake

  • Sohn, Myong-Hwan;Chung, Hyoung-Seog
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • The vortex flow characteristics of a double-delta wing, which can change the incidence angle of its apex strake was investigated through the wing-surface pressure measurement and the particle image velocimetry(PIV) measurement of the wing-leeward flow region. The apex strake has sharp edges and can change its incidence angle with a hinge line at the 23% chord position measured from the apex of the main wing. The present study revealed that the incidence-angle change of the apex strake could greatly alter the vortex flow pattern around the double-delta wing and the wing-surface pressure distribution, which suggested that the apex strake could be used as an effective device for the active control of delta-wing vortex flow.

IN VITRO EVALUATION OF ACCURACY AND CONSISTENCY OF FOUR DIFFERENT ELECTRONIC APEX LOCATORS (4종 전자근관장측정기의 정확성과 일관성에 관한 in vitro 연구)

  • Cho, Jae-Hyun;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.390-397
    • /
    • 2006
  • The purpose of this study was to evaluate the accuracy and the consistency of four different electronic apex locators in an in vitro model. Fourty extracted premolars were used for the study. Four electronic apex locators (EAL) were Root ZX, Smarpex, Elements Diagnostic Unit (EDU), and E-Magic Finder Deluxe (EMF). After access preparation, the teeth were embedded in an alginate model and the length measurements were carried out at '0.5' and 'Apex' mark using four EALs. The file was cemented at the location of the manufacturers' instruction (Root ZX, EDU, EMF: 0.5 mark, SmarPex: Apex mark). The apical 4mm of the apex was exposed and the distance from the file tip to the major foramen was measured by Image ProPlus (${\times}100$). The distance from the file tip to the major foramen was calculated at 0.5 and Apex mark and the consistency of 0.5 and Apex mark was compared by SD and Quartile of Box plots. In this study, Root ZX and EMF located the apical constriction accurately within ${\pm}0.5 mm$ in 100%, whereas SmarPex and EDU located in 90% and in 70% respectively. For Root ZX and EMF, there was no significant difference between the consistency of 0.5 and Apex mark. However, for the EDU and SmarPex, Apex mark was more consistent than 0.5 mark. From the evaluation of the consistency in this study, for Root ZX and EMF, both 0.5 and Apex mark can be used as a standard mark. And for EDU and SmarPex, the Apex mark can be recommended to be used as a standard mark.