• 제목/요약/키워드: ANSI/IEEE standard

검색결과 11건 처리시간 0.023초

ANSI/IEEE를 적용한 초고압 차단기의 차단시험 (Breaking test of UHV circuit breaker by ANSI/IEEE standard)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

ANSI/IEEE Std. 754-1985에 의거한 부동소수점 연산기의 동작원리에 관한 연구 (A Study on the Behavior of Floating-Point Unit Conforming the ANSI/IEEE Std. 754-1985)

  • 김광욱;정태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.788-790
    • /
    • 1999
  • A software implementation of floating-point addition and multiplication is presented. For this, the ANSI/IEEE standard for binary floating-point arithmetic is reviewed briefly. The architecture and behavior of the $Intel^{(R)}\;80{\times}87$ FPU is fully studied and basic algorithms for floating-point addition and multiplication are used for the implementation. Some examples and their verifications are also presented.

  • PDF

ANSI/IEEE 기술규격 분석 및 RTDS에 의한 고장전류 계산 비교 (Analysis of ANSI/IEEE Standard & Short-Circuit Calculations according to RTDS)

  • 차승태;추진부;윤용범;김재철;김세경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.231-233
    • /
    • 2002
  • 본 논문에서는 국제기술규격인 ANSI/IEEE의 고장전류 계산기준을 분석하였고, 외국 전력사의 고장전류 계산 기준을 정리하였다. 계통에서의 차단기 용량 선정은 고장전류 크기가 시간 경과에 따라 다르게 됨으로 차단기 차단시간(interrupting time)특성을 복합적으로 고려하여야 한다. 그러나, 현재 한전에서 사용하고 있는 고장전류 계산은 별도의 차단기 차단시간을 고려한 배수(multiplying factor)를 고려하지 않고 동기발전기 차과도 임피던스만 고장전류 공급원으로 취급하여 계산하고 있다. 이에 본 논문에서는 ANSI/IEEE규격에서 권장하는 내용과 외국 전력사의 고장전류 계산 기준을 종합 정리하였고, 고장전류 계산 예를 한전사용(PSS/E) 및 RTDS를 이용한 경우로 나누어 수행하고 모의 결과를 제시하고자 한다.

  • PDF

경계면 스캔 기저 구조를 위한 지연시험 (Delay Test for Boundary-Scan based Architectures)

  • 강병욱;안광선
    • 전자공학회논문지A
    • /
    • 제31A권6호
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

원자력발전소 안전계통 소프트웨어의 동적시험에 관한 연구 (A Study on Dynamic Test of Safety System Software on Nuclear Power Plant)

  • 문채주;장영학;이순성;서영
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.213-223
    • /
    • 1999
  • 최근 원자력발전소의 안전계통 소프트웨어는 신뢰성을 향상시키기 위해 ANSI/IEEE-ANS-7-4.3.2-1982 기준에 따라 확인 및 검증이 이루어지고 있다. 이 규정은 안전관련 소프트웨어가 정적 및 동적 환경에서 시험되어야 한다고 요구하고 있다. 부적절노심냉각감시계통의 경우에 정적시험 절차 및 관련기술들은 개발되었으나 동적시험 절차 및 관련기술들은 개발되지 않았다. 따라서, 본 논문에서는 미개발된 기술들을 논의하고, 동적시험 절차와 시험 입력자료 생성 프로그램을 제안한다. 이 프로그램의 성능은 울진 3,4호기 최종 안전성 분석 보고서의 사고해석 결과를 사용하여 확인하였다.

  • PDF

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

회복전압측정 방법을 통한 식물유와 광유에 따른 절연지의 수분 흡습 특성 (A moisture absorption characteristics of insulation papers on the vegetable oil impregnated paper and the mineral oil impregnated paper)

  • 정진혜;한상옥;이세현;박강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2034-2035
    • /
    • 2008
  • 본 논문은 RVM(Return Voltage measurement)을 이용하여 식물유와 광유에 따른 절연지의 수분 흡습성에 관한 특성을 비교하였다. 시험 절연재료로써 절연유는 각각 식물유(Bio Trans 1000,Cargill사)와 광유(제1종 2호, 동남석유(주))를 사용하였고, 절연지는 셀룰로오스계 크래프트 절연지를 사용하였다. 각 조건에서 IEEE/ANSI Standard C59.91-1981의 기대수명 곡선에서 $55^{\circ}C$ 절연을 기준으로하여 가속 열열화 시험을 수행한 후, $15^{\circ}C$씩 온도를 변화시켜 RVM 측정을 하였다.

  • PDF

가속수명시험에 의한 변압기 절연재료의 전기-기계적 특성 연구 (A Study of Electrical and Mechanical Characteristics by Accelerated Life Test)

  • 김주한;한상옥;김대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.28-30
    • /
    • 2007
  • 본 논문은 변압기의 과부하 상태를 모의하고 내부 절연물의 잔존수명을 평가하기 위한 방법으로 열적 스트레스를 인가한 가속 수명 시험을 수행하여 광유 함침 절연지의 전기적 기계적 열화 특성을 분석하였다. 시험에 사용된 절연 재료는 변압기의 주 절연물로 널리 사용하고 있는 셀룰로스계 크래프트 절연지와 광유계 절연유를 사용하였다. 가속 열열화 시험은 IEEE/ANSI Standard C59.91-1981의 수명 예측 곡선에 의거하여 국내 배전환경에 부합하도록 $55^{\circ}C$ 절연시스템을 기준으로 하였으며, $150^{\circ}C$에서 약 1,000시간 동안 열 스트레스를 인가함으로써 변압기의 수명이 다하도록 모의하였다.

  • PDF

가솔 열 열화 시험에 의한 광유 함침 절연지의 절연 열화 특성 (Degradation of Cellulose in Mineral Oil by Thermally Accelerated Aging Test)

  • 김주한;강석영;한희준;한상옥;이병성;이세현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1486-1487
    • /
    • 2006
  • 본 논문은 변압기의 과부하 상태를 모의하고 내부 절연물의 잔존수명을 평가하기 위한 방법으로 가속 열 열화 시험을 수행하였으며, 광유 함침 절연지의 열 스트레스에 의한 절연 열화 특성을 분석하였다. 시험에 사용된 절연재료는 변압기의 주 절연물로 널리 사용하고 있는 셀룰로스계 크래프트 절연지와 광유계 절연유를 사용하였다. 가속 열 열화 시험은 IEEE/ANSI Standard C59.91-1981의 수명 예측 곡선에 의거하여 국내 배전환경에 부합하도록 $55^{\circ}C$ 절연시스템을 기준으로 하였으며, $150^{\circ}C$에서 약 1,000시간 동안 열 스트레스를 인가함으로써 변압기의 수명이 다하도록 모의하였다. 또한 절연지의 절연 열화 특성을 분석하기 위해 인장강도, 비유전율, 절연파괴 강도를 시험하였다.

  • PDF

원자력 발전소 계측제어시스템의 정보취득장치 설계 (Data Acquisition System Design of I&C System in Nuclear Power Plant)

  • 조정환;이동희
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.102-108
    • /
    • 2003
  • 본 논문에서는 SDAS(Signal Data Acquisition System)를 설계하여 정밀도와 응답특성을 향상시킨 새로운 정보취득장치를 제안한다. 원자력 발전소에 적용되는 계측제어 시스템은 안전에 직접 또는 간접적으로 영향을 미치는 장치이므로 이들 기기는 안전등급의 분류에 따라 기기 검증의 절차에 의하여 현장 적용 이전에 주요 제어 설비가 설계명수 기간동안에 의도된 기능을 수행할 수 있음이 검증되어야 한다. 본 논문에서는 국제 기준 규격인 IEEE 규격과 Nuclear Regulatory Guide의 규격에 명시되어 있는 성능시험방법과 절차에 의한 기기검증에서 필수적인 장비인 정보취득장치를 제안하였고, 기존에 사용되고 있는 정보취득장치와 성능을 비교 분석하였다. 이론과 실험적인 연구가 수행되었고, 그 결과는 제안된 정보취득장치의 정밀도 성능이 개선되었음을 입증한다. 따라서 제안된 시스템은 고성능 계측제어시스템에 적용될 수 있다.