In recently, the safety system software of the nuclear power plant has been verified and validated according to ANSI/IEEE-ANS-7-4.3.2-1982 to improve the reliability. This standard requires that safety-related software should be tested in the static and dynamic environments. In case of Inadequate Core Cooling Monitoring System (ICCMS), the static test procedure and related techniques are developed but the dynamic test procedure and related techniques are not developed. Therefore, this paper discusses the undeveloped techniques, and suggests the dynamic test procedure and the program for generation of test input data. The performance of the program was identified using accident analysis report of Ulchin 3&4 Final Safety Analysis Report (FSAR).

최근 원자력발전소의 안전계통 소프트웨어는 신뢰성을 향상시키기 위해 ANSI/IEEE-ANS-7-4.3.2-1982 기준에 따라 확인 및 검증이 이루어지고 있다. 이 규정은 안전관련 소프트웨어가 정적 및 동적 환경에서 시험되어야 한다고 요구하고 있다. 부적절노심냉각감시계통의 경우에 정적시험 절차 및 관련기술들은 개발되었으나 동적시험 절차 및 관련기술들은 개발되지 않았다. 따라서, 본 논문에서는 미개발된 기술들을 논의하고, 동적시험 절차와 시험 입력자료 생성 프로그램을 제안한다. 이 프로그램의 성능은 울진 3,4호기 최종 안전성 분석 보고서의 사고해석 결과를 사용하여 확인하였다.