• Title/Summary/Keyword: ANSI/IEEE standard

Search Result 11, Processing Time 0.025 seconds

Breaking test of UHV circuit breaker by ANSI/IEEE standard (ANSI/IEEE를 적용한 초고압 차단기의 차단시험)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

A Study on the Behavior of Floating-Point Unit Conforming the ANSI/IEEE Std. 754-1985 (ANSI/IEEE Std. 754-1985에 의거한 부동소수점 연산기의 동작원리에 관한 연구)

  • Kim, Kwang-Uk;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.788-790
    • /
    • 1999
  • A software implementation of floating-point addition and multiplication is presented. For this, the ANSI/IEEE standard for binary floating-point arithmetic is reviewed briefly. The architecture and behavior of the $Intel^{(R)}\;80{\times}87$ FPU is fully studied and basic algorithms for floating-point addition and multiplication are used for the implementation. Some examples and their verifications are also presented.

  • PDF

Analysis of ANSI/IEEE Standard & Short-Circuit Calculations according to RTDS (ANSI/IEEE 기술규격 분석 및 RTDS에 의한 고장전류 계산 비교)

  • Cha, S.T.;Choo, J.B.;Yoon, Y.B.;Kim, J.C.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.231-233
    • /
    • 2002
  • 본 논문에서는 국제기술규격인 ANSI/IEEE의 고장전류 계산기준을 분석하였고, 외국 전력사의 고장전류 계산 기준을 정리하였다. 계통에서의 차단기 용량 선정은 고장전류 크기가 시간 경과에 따라 다르게 됨으로 차단기 차단시간(interrupting time)특성을 복합적으로 고려하여야 한다. 그러나, 현재 한전에서 사용하고 있는 고장전류 계산은 별도의 차단기 차단시간을 고려한 배수(multiplying factor)를 고려하지 않고 동기발전기 차과도 임피던스만 고장전류 공급원으로 취급하여 계산하고 있다. 이에 본 논문에서는 ANSI/IEEE규격에서 권장하는 내용과 외국 전력사의 고장전류 계산 기준을 종합 정리하였고, 고장전류 계산 예를 한전사용(PSS/E) 및 RTDS를 이용한 경우로 나누어 수행하고 모의 결과를 제시하고자 한다.

  • PDF

Delay Test for Boundary-Scan based Architectures (경계면 스캔 기저 구조를 위한 지연시험)

  • 강병욱;안광선
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

A Study on Dynamic Test of Safety System Software on Nuclear Power Plant (원자력발전소 안전계통 소프트웨어의 동적시험에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;Lee, Sun-Sung;Suh, Young
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.213-223
    • /
    • 1999
  • In recently, the safety system software of the nuclear power plant has been verified and validated according to ANSI/IEEE-ANS-7-4.3.2-1982 to improve the reliability. This standard requires that safety-related software should be tested in the static and dynamic environments. In case of Inadequate Core Cooling Monitoring System (ICCMS), the static test procedure and related techniques are developed but the dynamic test procedure and related techniques are not developed. Therefore, this paper discusses the undeveloped techniques, and suggests the dynamic test procedure and the program for generation of test input data. The performance of the program was identified using accident analysis report of Ulchin 3&4 Final Safety Analysis Report (FSAR).

  • PDF

Fault Current Calculation and Coordination by IEC Standards (IEC 표준에 의한 고장전류 계산과 보호협조)

  • Son, Seok-Geum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

A moisture absorption characteristics of insulation papers on the vegetable oil impregnated paper and the mineral oil impregnated paper (회복전압측정 방법을 통한 식물유와 광유에 따른 절연지의 수분 흡습 특성)

  • Jeong, Jin-Hye;Han, Sang-Ok;Lee, Sei-Hyun;Park, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2034-2035
    • /
    • 2008
  • 본 논문은 RVM(Return Voltage measurement)을 이용하여 식물유와 광유에 따른 절연지의 수분 흡습성에 관한 특성을 비교하였다. 시험 절연재료로써 절연유는 각각 식물유(Bio Trans 1000,Cargill사)와 광유(제1종 2호, 동남석유(주))를 사용하였고, 절연지는 셀룰로오스계 크래프트 절연지를 사용하였다. 각 조건에서 IEEE/ANSI Standard C59.91-1981의 기대수명 곡선에서 $55^{\circ}C$ 절연을 기준으로하여 가속 열열화 시험을 수행한 후, $15^{\circ}C$씩 온도를 변화시켜 RVM 측정을 하였다.

  • PDF

A Study of Electrical and Mechanical Characteristics by Accelerated Life Test (가속수명시험에 의한 변압기 절연재료의 전기-기계적 특성 연구)

  • Kim, Ju-Han;Han, Sang-Ok;Kim, Dae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.28-30
    • /
    • 2007
  • 본 논문은 변압기의 과부하 상태를 모의하고 내부 절연물의 잔존수명을 평가하기 위한 방법으로 열적 스트레스를 인가한 가속 수명 시험을 수행하여 광유 함침 절연지의 전기적 기계적 열화 특성을 분석하였다. 시험에 사용된 절연 재료는 변압기의 주 절연물로 널리 사용하고 있는 셀룰로스계 크래프트 절연지와 광유계 절연유를 사용하였다. 가속 열열화 시험은 IEEE/ANSI Standard C59.91-1981의 수명 예측 곡선에 의거하여 국내 배전환경에 부합하도록 $55^{\circ}C$ 절연시스템을 기준으로 하였으며, $150^{\circ}C$에서 약 1,000시간 동안 열 스트레스를 인가함으로써 변압기의 수명이 다하도록 모의하였다.

  • PDF

Degradation of Cellulose in Mineral Oil by Thermally Accelerated Aging Test (가솔 열 열화 시험에 의한 광유 함침 절연지의 절연 열화 특성)

  • Kim, Ju-Han;Kang, Seok-Young;Han, Hee-Jun;Han, Sang-Ok;Lee, Byung-Seong;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1486-1487
    • /
    • 2006
  • 본 논문은 변압기의 과부하 상태를 모의하고 내부 절연물의 잔존수명을 평가하기 위한 방법으로 가속 열 열화 시험을 수행하였으며, 광유 함침 절연지의 열 스트레스에 의한 절연 열화 특성을 분석하였다. 시험에 사용된 절연재료는 변압기의 주 절연물로 널리 사용하고 있는 셀룰로스계 크래프트 절연지와 광유계 절연유를 사용하였다. 가속 열 열화 시험은 IEEE/ANSI Standard C59.91-1981의 수명 예측 곡선에 의거하여 국내 배전환경에 부합하도록 $55^{\circ}C$ 절연시스템을 기준으로 하였으며, $150^{\circ}C$에서 약 1,000시간 동안 열 스트레스를 인가함으로써 변압기의 수명이 다하도록 모의하였다. 또한 절연지의 절연 열화 특성을 분석하기 위해 인장강도, 비유전율, 절연파괴 강도를 시험하였다.

  • PDF

Data Acquisition System Design of I&C System in Nuclear Power Plant (원자력 발전소 계측제어시스템의 정보취득장치 설계)

  • 조정환;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.102-108
    • /
    • 2003
  • This paper presents a new Data acquisition system that can improve a accuracy and response characteristics by designing a SDAS(Signal Datat Acquisition System). I&C(Instrumentation and Control) system, which it applied for Nuclear Power Plant, affects for safety either directly or indirectly. It should be assessed by the equipment qualification procedure to confirm the functionality during design life before it apply on the nuclear power plant depending on safety classification. This paper proposes data acquisition system that required as an essential measurement equipment in the method and procedure of equipment qualification following of standards and codes of IEEE and Nuclear Regulatory Guide. It provides comparable and experimental studies have been carried out. The presented results from the above investigation show considerably improved accuracy performance in the data acquisition system. This circuit will be able to be used in high performance I&C system.