• Title/Summary/Keyword: AIx

Search Result 67, Processing Time 0.026 seconds

AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry (토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화)

  • Cho, JungHee;Jeon, Young Ju;Jun, Min-Ho;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

Characteristic behaviors of the AIx depending on the palpation positions (맥진 위치에 따른 AIx 변화 특성 연구)

  • Jeon, Young-Ju;Kim, Jae-Uk;Lee, Yu-Jung;Ryu, Hyun-Hee;Lee, Hae-Jung;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1966_1967
    • /
    • 2009
  • As an attempt to characterize the pulse behaviors at the three pulse diagnosis positions in the oriental medicine which are called Chon, Gwan, and Cheok, we measure the pluse waveforms by SphygmoCor apparatus, that has been used widely for the evaluation of the arterial stiffness, and examine the Augmentation Index (AIx) at the aorta. For the study, twenty healthy men at the age of twenties have participated as the subject group. The pulse has been measured twice at the three palpation positions, and by two-way repeated measures ANOVA we tested the repeatability and the mean differences in the aortic AIx between Chon, Gwan, and Cheok. The AIx was found to be statistically different between the measurement positions. Duncan's test shows that the AIx is statistically different between Chon and the other two positions. Our study may be used as a reference for further scientific quantification of the pulse diagnosis.

  • PDF

Influence of commercial detergents on UF membrane ageing: Case of drinking water

  • Moulin, P.;Regula, C.;Carretier, E.;Wyart, Y.;Sergent, M.;Gesan-Guiziou, G.;Ferry, D.;Vincent, A.;Boudot, D.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.27-51
    • /
    • 2013
  • During cleaning steps, ultrafiltration membranes are mechanically and chemically stressed. This may result in membrane degradations and failures. In this paper, polysulfone membranes were used to evaluate membrane deteriorations by commercial detergents in static conditions. Ageing of the membrane was simulated by immersing samples in solutions containing commercial detergents with various concentrations, temperatures and times defined by experimental designs. Indeed, an innovative approach in the chemical membranes ageing researches, based on methodological tools, was used in order to achieve significant ageing experiments without using an accelerated ageing protocol. The macroscopic changes were monitored by permeability measurements and mechanical strength tests coupled with a microscopic characterization by ATR-FTIR and HRSEM. The present work details results obtained for three commercial detergents: an alkaline, an acidic and an enzymatic detergent. It was found that the detergents used in the industrial advised conditions (concentration, temperature and time of contact) were not detrimental for membrane properties (permeability and elongation at break) and so for the quality of the produced water. Over the industrial cumulated time of contact, different ageing effects can be observed and compared with the ones induced by NaOCl.

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

FAR INFRARED GALAXIES IN AKARI'S EYE

  • Malek, K.;Pollo, A.;Takeuchi, T.T.;Giovannoli, E.;Buat, V.;Burgarella, D.;Malkan, M.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.141-144
    • /
    • 2012
  • We present the results of Spectral Energy Distribution (SED) fitting of far-infrared galaxies detected in the AKARI Deep Field-South (ADF-S) Survey and discuss their physical properties. Additionally, we perform a comparison between photometric redshifts estimated using only optical and both optical and infrared data. We conclude that our sample consists mostly of nearby galaxies rich in dust and young stars. We observe an improvement in the estimation of photometric redshifts when the IR data are included, comparing to a standard approach based mainly on the optical to UV photometry.

Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure (5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석)

  • Kwon, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

AKARI-SDSS-GALEX SURVEYS: SPECTRAL ENERGY DISTRIBUTIONS OF NEARBY GALAXIES

  • Buat, V.;Yuan, F.T.;Takeuchi, T.T.;Giovannoli, E.;Heinis, S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.317-320
    • /
    • 2012
  • A sample of nearby galaxies was built from the AKARI/FIS all sky survey cross-correlated with the SDSS and GALEX surveys. The spectral energy distributions from 0.15 to 160 microns of these galaxies are analysed to study dust attenuation and star formation properties. The calibrations of the amount of dust attenuation as a function of the IR-to-UV flux ratio and the FUV-NUV colour are re-investigated: the former one is confirmed to be robust and accurate whereas the use of the FUV-NUV colour to measure dust attenuation is found highly uncertain. The current star formation rate given by the SED fitting process is compared to that directly obtained from the UV and total IR luminosities. It leads to an accurate estimate of dust heating by old stars. We emphasize the importance of such a sample as a reference for IR selected star forming galaxies in the nearby universe.

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S.;Wyart, Y.;Perot, J.;Nauleau, F.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.53-67
    • /
    • 2013
  • In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

Horizon-AGN virtual observatory: SED-fitting performance and forecasts for future imaging surveys

  • Laigle, Clotilde;Davidzon, I.;Ilbert, O.;Devriendt, J.;Kashino, D.;Capak, P.;Arnouts, S.;De la Torre, S.;Dubois, Y.;Gozaliasl, G.;Leborgne, D.;McCracken, H.J.;Pichon, C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.32.3-32.3
    • /
    • 2018
  • We use the synthetic light-cone from the cosmological hydrodynamical simulation Horizon-AGN to produce a mock photometric galaxy catalogue on the redshift range 0

  • PDF

Estimation of the Central Aortic Pulse using Transfer Function and Improvement of an Augmentation Point Detection Algorithm (전달함수를 이용한 대동맥 맥파 추정 및 증강점 검출 알고리즘 개선에 관한 연구)

  • Im, Jae-Joong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.68-79
    • /
    • 2008
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness quantitatively and even to evaluate ventricular load. However, in order to calculate aortic AIx catheters should be inserted to the subjects' artery, which hampers its clinical usage. To overcome such limitation, aortic AIx has been indirectly calculated by estimating aortic pressure wave from the peripheral arterial pulse by applying transfer functions. In this study, central aortic pressure waves using Millar catheter and radial artery pulse waves using tonometry pressure sensor were measured to establish transfer functions for an estimation of central aortic pressure waves from radial artery pulse waves. Also, an algorithm which detects augmentation point for the calculation of AIx were developed. Developed algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Transfer functions were established using 10th order ARX model and were verified for the stability of the transfer function through residual analysis. Evaluation of an algorithm for the detection of augmentation point were performed by comparing the augmentation points obtained from developed algorithm with the known augmentation points synthesized in various conditions. In addition, developed algorithm for the AIx is proved to provide more accurate results than the ones developed by previous studies. The significance of the study was in two folds. Firstly, the results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and secondly, extension of the study may enable the early diagnosis of various vascular diseases.