• Title/Summary/Keyword: AIR ION INDEX

Search Result 16, Processing Time 0.032 seconds

Evaluation of Air Ion According to Vegetation Types in Valleys and Slopes - Focused on Tangeumdae Park in ChungJu - (계곡·사면부의 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 -)

  • Yoon, Young-Han;Lee, Sang-Hoon;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.519-529
    • /
    • 2020
  • The purpose of this study was to provide basic health care data for the climate aspects of park re-cultivation by evaluating air ions according to the type of vegetation in the valley and upper slopes of the mountain park. Simple negative or positive air ions were expected to show the same tendencies, so they were analyzed in terms of correcting the air ion index. By analyzing the air ions according to the topography, it was found that valley > slope in terms of the air ion index. When analyzing air ions according to tree species, we found that evergreen conifers in the valley > the deciduous broad-leaved trees in the valley > the evergreen conifers in the slope = the deciduous broad-leaved trees in the slope. For DBH(Diameter at breast height), the valley large pole > slope large pole > slope medium hard wood, while crown density was analyzed as valley dense > slope dense> valley proper > slope proper. Layered structure analysis showed that the multi-layer structure of the valley > multi-layer structure of the slope = the single-layer structure of the valley > the single-layer structure of the slope. The correlation coefficient was determined according to vegetation type and air ion index in the order of DBH > crown density > layer structure > geomorphic structure. In this study, limits exist except for ridge line, valley, and slopes in urban mountain parks. Therefore, analysis should be made considering both topographical structure and various vegetation types in future studies of air ions.

Evaluation of Air Ion According to the Type of Ridge in Urban Park -Focused on Tangeumdae Park in ChungJu- (도심 산지형 공원 능선부 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.5
    • /
    • pp.587-595
    • /
    • 2019
  • This study analyzed the influence of the environmental factor of each vegetation type in an urban, mountainous park (Tangeumdae Park in Chungju) on air ion. The measuring points were divided according to the tree species, diameter at breast height, crown density, and layered structure, and the meteorological factors and the air ion were measured. The results of the measurement showed the average generation of positive ions of $610.90{\pm}50.27ea/cm^3$, the average generation of negative ions of $723.58{\pm}64.25ea/cm^3$, and the air ion index of $1.19{\pm}0.10$. The results of the analysis, according to the vegetation type, are as follows. Firstly, the air ion varied according to the species, the chest diameter at breast height, and the layered structure, and was analyzed to be statistically significant. Secondly, the air ion and the vegetation type showed a positive correlation with the species, diameter at breast height, crown density, and layered structure. The cation showed a negative correlation with the species, diameter at breast height, and the crown density, and the anion showed a positive correlation with the species, the diameter at breast height, crown density, and layered structure. Thirdly, the ion index in ridges had a higher correlation with the vegetation type than the meteorological factors. In detail, the correlation was higher in the species > layered structure > crown density > diameter at breast height. This study had the limitation of evaluating air ions in the ridge. Therefore, future studies on air ion should consider both terrain structure and vegetation type and analyze the seasonal changes and comparison.

Ion assisted deposition of $TiO_2$, $ZrO_2$ and $SiO_xN_y$ optical thin films

  • Cho, H.J.;Hwangbo, C.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.75-79
    • /
    • 1997
  • Optical and mechanical characteristics of $TiO-2, ZrO_2 \;and\; SiO_xN_y$ thin films prepared by ion assisted deposition (IAD) were investigated. IAD films were bombarded by Ar or nitrogen ion beam from a Kaufman ion source while they were grown in as e-beam evaporator. The result shows that the Ae IAD increases the refractive index and packing density of $TiO_2 films close to those of the bulk. For $ZrO_2$ films the Ar IAD increases the average refractive index decreases the negative inhomogeneity of refractive index and reverses to the positive inhomogeneity. The optical properties result from improved packing density and denser outer layer next to air The Ar-ion bombardment also induces the changes in microstructure of $ZrO_2$ films such as the preferred (111) orientation of cubic phase increase in compressive stress and reduction of surface roughness. Inhomogeneous refractive index SiOxNy films were also prepared by nitrogen IAD and variable refractive index of $SiO_xN_y$ film was applied to fabricate a rugate filter.

  • PDF

항균처리를 한 공조기기의 항균성능 평가방법과 평가결과

  • Miura, Kunio;Takatsuka, Takesi;Yanagi, U;Yamazaki, Shoji
    • Air Cleaning Technology
    • /
    • v.22 no.2
    • /
    • pp.40-49
    • /
    • 2009
  • Aluminum thin plate coated with epoxy resin containing about 20wt% brass powder, was applied to fins of heat exchanger. We carried out a series of detailed examinations to evaluate the anti-bacterial performance of the plate and heat exchanger (fan coil unit). In the presence of water or moisture, copper ions which have an anti-bacterial ability eluted from brass powder and showed sufficient effects on many kinds of bacteria. We also evaluated the anti-bacterial performance quantitatively by use of the index API (Anti-bacterial Performance Index) which has already been proposed by authors.

  • PDF

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

Evaluation of Pedestrian Space Ion Index by Land Use Type in Heat wave - Focused on ChungJu - (폭염시 토지이용유형별 보행공간 이온지수 평가 - 충주시를 대상으로 -)

  • Yoon, Yong Han;Yoon, Ji Hun;Kim, Jeong Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.354-365
    • /
    • 2019
  • This study measured and analyzed the weather characteristics and the air-ion characteristics of walking space by land use type in Chungju, Chungcheongbuk Province during the heat wave. We used the land registration map to classify the type of land use in walking areas in the studied into the production and green area, the residential area, and the commercial area. We then selected 44 measurement points in about 4.1 km. They included 12 walking space points in the green area, 14 in the residential area, and 18 in the commercial area. Moreover, we calculated the ion index by analyzing the impact of weather factors such as temperature, relative humidity, solar radiation, and net radiation in the walking space on the anion generation and cation generation by land use type during the heat wave. Comparison of air ion characteristics in walking space by type of land use during the heat wave showed that the average cation generation was in the order of commercial area ($700.73cations/cm^3$) > residential area ($600.76cations/cm^3$) > green area ($589.73cations/cm^3$). The average anion generation was in the order of green area ($663.95anions/cm^3$) > residential area ($628.48anions/cm^3$) > commercial area ($527.48anions/cm^3$). The average ion index was in the order of green area (1.13) > residential area (1.04) > commercial area (0.75). This study checked the weather characteristics, cation generation, and anion generation in walking space according to the land use type during the heat wave and checked the difference of ion indexes in the walking space according to the land use type. However, there were limitations in the lack of accurate comparison according to the land use due to the moving measurement and the insufficient quantitative comparison according to the change of road width. Therefore, we recommend further studies that consider the road characteristics.

Preparation of low refractive index $SiO_xF_y$ optical thin films by ion beam assisted deposition (이온빔보조증착으로 제작한 저굴절률 $SiO_xF_y$ 광학박막의 특성 연구)

  • 이필주;황보창권
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.162-167
    • /
    • 1998
  • $SiO_xF_y$ optical thin films of lower refractive indices than glass substrates were fabricated by the CF$_4$ ion beam assisted deposition method and the optical, structural and chemical properties of them were investigated. Refractive index of $SiO_xF_y$ films was varied from 1.455 to 1.394 by decreasing the anode voltage or from 1.462 to 1.430 by increasing the current density of end-Hall ion source. FT-IR and XPS analyses show that as the F concentration increases, the Si-O bond at $1080m^{-1}$ shifts to higher wavenumber, the OH bonds are reduced drastically, and the fluorine atoms at the air-film interface are desorbed out by reacting with $H_2O$ in the atmosphere. $SiO_xF_y$ thin films are amorphous by the XRD analysis and have the compressive stress below 0.3 GPa. As an application of $SiO_xF_y$ thin films a two-layer antireflection coating was fabricated using a $SiO_xF_y$ film as a low refractive index layer and a Si film as an absorbing one.

  • PDF

Effect of pH and Iron/Manganese Ion on TiO2 Mediated Photocatalytic Inactivation of Index Microorganisms (LNAPL을 이용한 지중 산소전달 향상: (I) Abiotic Condition)

  • Ha, Jeong-Hyub;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.307-311
    • /
    • 2004
  • The objective of this work is to evaluate the hypothesis that a good technique for supplying oxygen to the saturated zone in the presence of light nonaqueous phase liquid (LNAPL) pool contamination at the water table is to pass air through the unsaturated zone above the pool. This hypothesis was evaluated in experimental studies performed using a bench-scale, sand-tank reactor, Steady-state abiotic experiments in the sand-tank reactor with air flowing through the reactor headspace demonstrated that oxygen supply through the water table interface into the saturated zone was enhanced when an LNAPL (dodecane) pool was present at the water table. These experimental results confirmed the hypothesis that an LNAPL pool can serve as a high concentration oxygen source to the oxygen-limited area beneath the pool and, as a result, enhance the in situ biodegradation rate.

Optical properties of Nb2O5 thin films prepared by ion beam assisted deposition (이온빔 보조 증착 Nb2O5 박막의 광학적 특성)

  • 우석훈;남성림;정부영;황보창권;문일춘
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.105-112
    • /
    • 2002
  • We studied the optical and structural properties of conventional and ion-beam-assisted-deposition (IBAD) Nb$_2$O$_{5}$ films which were evaporated by an electron beam gun. The vacuum-to-air spectral shift and the cross sectional SEM images of the Nb$_2$O$_{5}$ films were investigated. The results show that the IBAD Nb$_2$O$_{5}$ films have a higher packing density than the conventional Nb$_2$O$_{5}$ films. The average refractive index of IBAD Nb$_2$O$_{5}$ films was increased, while the extinction coefficient was decreased compared with the conventional films. As the oxygen flow was increased, the average refractive index and extinction coefficient of the conventional and IBAD films decreased. Both the conventional and IBAD Nb$_2$O$_{5}$ films showed inhomogeneity in refractive index, and the degree of inhomogeneity of the IBAD Nb$_2$O$_{5}$ films became larger as the ion current density was increased. All Nb$_2$O$_{5}$ films were found to be amorphous by x-ray diffraction (XRD) analysis, and hence the crystal structure of Nb$_2$O$_{5}$ films was not changed by IBAD.

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.