• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.059 seconds

Installation and Data Analysis of Superconducting Gravimeter in MunGyung, Korea; Preliminary Results (문경 초전도 중력계 설치 및 기초자료 분석)

  • Kim, Tae-Hee;Neumeyer, Juergen;Woo, Ik;Park, Hyuck-Jin;Kim, Jeong-Woo
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.445-459
    • /
    • 2007
  • Superconducting Gravimeter(SG) was installed and has been successfully operated at MunGyung, Kyungsang province in Korea in March 2005. It was registered as the 21st observatory of the Global Geodynamics Project. Since SG can precisely measure the gravity variations below the 1mHz frequency band, it has the outstanding capability to sense and resolve many different periodic gravity components from each other. From the raw data collected between 18 March 2005 and 21 February 2006 diurnal and semi-diurnal tidal band's residual gravity components were analyzed. During this process, the instrumental noises, air pressure, and ground water corrections were carried out. Values of $-3.18nm/s^2/hPa\;and\;17nm/s^2/m$ were used respectively in the air pressure and groundwater corrections. Hartmann-Wenzel and Whar-Dehant Earth tide models were adopted to compute the residual gravity for Q1, O1, P1, K1, M2, N2, S2, K2 tidal bands. For the ocean loading correction, SCW80, FES952, and FES02 models were used and compared. As a result, FES02 ocean loading model has shown the best match for the data processing at MunGyung SG MunGyung SG gravity was compared with GRACE satellite gravity. The correlation coefficient between the two gravity after groundwater correction was 0.628, which is higher than before ground water correction. To evaluate sensitivity at MunGyung SG gravity statition, the gravity data measured during 2005 Indodesian earthquake was compared with STS-2 broad band seismometer data. The result clearly revealed that the SG could recorded the same period of earthquake with seismometer event and a few after-shock events those were detected by seismometer.

Study on Detailed Air Flows in Urban Areas Using GIS Data in a Vector Format and a CFD Model (벡터 형식의 GIS 자료와 CFD 모델을 이용한 도시 지역 상세 대기 흐름 연구)

  • Kwon, A-Rum;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.755-767
    • /
    • 2014
  • In this study, detailed air flow characteristics in an urban areas were analyzed using GIS data and a Computational Fluid Dynamics (CFD) model. For this, a building construction algorithm optimized for Geographic Information System (GIS) data with a vector format (Los Angeles region imagery acquisition consortium 2 geographic information system, LARIAC2 GIS) was used. In the LARIAC2 GIS data, building vertices were expressed as latitude and longitude. Using the model buildings constructed by the algorithm as the surface boundary data in the CFD model, we performed numerical simulations for two building-congested areas in Los Angeles using inflow information provided by California Air Resources Board. Comparing with the inflow, there was a marked difference in wind speed and direction within the target areas, which was mainly caused by the secondarily induced local circulations such as street-canyon vortices, horse-shoe vortices, and recirculation zones. In street canyons parallel to the inflow direction, wind speed increased due to a channeling effect and, in street canyons perpendicular to the inflow direction, vertically well developed vortices were induced. In front of a building, a horse-shoe vortex was developed near the surface and, behind a building, a recirculation zone was developed. Near the surface in the areas where the secondarily induced local circulations, wind speed remarkably increased. Overall, wind direction little (largely) changed at the areas where wind speed largely increased (decreased).

Current and Future Changes in the Type of Wintertime Precipitation in South Korea (현재와 미래 우리나라 겨울철 강수형태 변화)

  • Choi, Gwang-Yong;Kwon, Won-Tae
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.1
    • /
    • pp.1-19
    • /
    • 2008
  • This study intends to clarify the characteristics and causes of current changes in wintertime precipitation in Korea and to predict the future directions based on surface observational $(1973/04\sim2006/07)$ and modeled (GFDL 2.1) climate data. Analyses of surface observation data demonstrate that without changes in the total amount of precipitation, snowfall in winter (November-April) has reduced by 4.3cm/decade over the $1973\sim2007$ period. Moreover, the frequency and intensity of snowfall have decreased; the duration of snow season has shortened; and the snow-to-rain day ratio (STDR) has decreased. These patterns indicate that the type of wintertime precipitation has changed from snow to rain in recent decades. The snow-to-rain change in winter is associated with the increases of air temperature (AT) over South Korea. Analyses of synoptic charts reveal that the warming pattern is associated with the formation of a positive pressure anomaly core over northeast Asia by a hemispheric positive winter Arctic Oscillation (AO) mode. Moreover, the differentiated warming of AT versus sea surface temperature (SST) under the high pressure anomaly core reduces the air-sea temperature gradient, and subsequently it increases the atmospheric stability above oceans, which is associated with less formation of snow cloud. Comparisons of modeled data between torrent $(1981\sim2000)$ and future $(2081\sim2100)$ periods suggest that the intensified warming with larger anthropogenic greenhouse gas emission in the $21^{st}$ century will amplify the magnitude of these changes. More reduction of snow impossible days as well as more abbreviation of snow seasons is predicted in the $21^{st}$ century.

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.

Improvement of COMS land surface temperature retrieval algorithm by considering diurnal variation of air temperature (기온의 일 변동을 고려한 COMS 지표면온도 산출 알고리즘 개선)

  • Choi, Youn-Young;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.5
    • /
    • pp.435-452
    • /
    • 2016
  • Land Surface Temperature (LST) has been operationally retrieved from the Communication, Ocean, and Meteorological Satellite (COMS) data by the spilt-window method (CSW_v2.0) developed by Cho et al. (2015). Although the CSW_v2.0 retrieved the LST with a reasonable quality compared to the Moderate Resolution Imaging Spectroradiometer (MODIS) LST data, it showed a relatively poor performance for the strong inversion and lapse rate conditions. To solve this problem, the LST retrieval algorithm (CSW_v2.0) was updated using the simulation results of radiative transfer model (MODTRAN 4.0) by considering the diurnal variations of air temperature. In general, the upgraded version, CSW_v3.0 showed a similar correlation coefficient between the prescribed LSTs and retrieved LSTs (0.99), the relatively smaller bias (from -0.03 K to-0.012 K) and the Root Mean Square Error (RMSE) (from 1.39 K to 1.138 K). Particularly, CSW_v3.0 improved the systematic problems of CSW_v2.0 that were encountered when temperature differences between LST and air temperature are very large and/or small (inversion layers and superadiabatic lapse rates), and when the brightness temperature differences and surface emissivity differences were large. The bias and RMSE of CSW_v2.0 were reduced by 10-30% in CSW_v3.0. The indirect validation results using the MODIS LST data showed that CSW_3.0 improved the retrieval accuracy of LST in terms of bias (from -0.629 K to -0.049 K) and RMSE (from 2.537 K to 2.502 K) compared to the CSW_v2.0.

Evaluation of the Air Temperature and Wind Observation Environments Around Automated Synoptic Observing Systems in Summer Using a CFD Model (전산유체역학 모델을 활용한 여름철 종관기상관측소의 기온과 바람 관측 환경 평가)

  • Kang, Jung-Eun;Rho, Ju-Hwan;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.471-484
    • /
    • 2022
  • This study examined the effects of topography and buildings around the automated synoptic observing system (ASOS) on the observation environment of air temperatures and wind speeds and directions using a computational fluid dynamics(CFD) model. For this, we selected 10 ASOSs operated by the Korea Meteorological Administration. Based on the data observed at the ASOSs in August during the recent ten years, we established the initial and boundary conditions of the CFD model. We analyzed the temperature observation environment by comparing the temperature change ratios in the case considering the actual land-cover types with those assuming all land-cover types as grassland. The land-cover types around the ASOSs significantly affected the air temperature observation environment. The temperature change ratios were large at the ASOSs around which buildings and roads were dense. On the other hand, when all land covers were assumed as grassland, the temperature change ratios were small. Wind speeds and directions at the ASOSs were also significantly influenced by topography and buildings when their heights were higher or similar to the observation heights. Obstacles even located at a long distance affected the wind observation environments. The results in this study would be utilized for evaluating ASOS observation environments in the relocating or newly organizing steps.

A Comparative Analysis of Negative Air Ions according to the Planting Structure at School Forests (학교 숲 식재구조에 따른 음이온 발생량 비교 분석)

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Park, Yong-Gwan;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, negative air ions, which can increase comfort and positively influence human health, was set as an evaluative factor for school forests. The characteristics, location and microclimate of school forests were examined to determine an effective school forest model for maximum negative air ion generation. It also aimed to provide basic data for the development of urban green fields. The negative air ion concentrations were different according to the green types. The order from the highest to the lowest was: single-layer structure($934ea/cm^3$) > multi-layer structure($794ea/cm^3$) > grass($553ea/cm^3$) > bare ground($529ea/cm^3$). As for the correlation with microclimate, negative air ion concentration was negatively correlated with temperature. The negative air ion concentration was significantly different according to planting type. The negative air ion concentration was higher at single-layer structure sites than at multi-layer structure sites, which appears to indicate that the temperature is higher when the vegetation structure was single-layer compared to multi-layer. Wind speed was higher at the single-layer planted site than at the multi-layer planted site. The vegetation wind shielding effect was lower at single-layer planted sites than at multi-layer planted sites. The single-layer planted site provided more favorable conditions for the generation and dispersion of negative air ions.

Enhanced Removal of Benzene-NAPL in Soil using Concurrent Injection of Cosolvent and Air (Cosolvent와 공기 동시 주입 공정에 의한 토양 내 벤젠-NAPL 세정 증대 연구)

  • Song, Chung-Hyun;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1095-1101
    • /
    • 2008
  • Nonaqueous phase liquids (NAPL) are the continuous source for soil and groundwater contamination. The first objective of the study was to verify the effect of co-injection of cosolvent and air on NAPL removal from soil-column system. The second objective of the study was to investigate the effect of alcohol-partitioning property on the NAPL removal by the co-injection process of cosolvent and air. Enhanced removal of benzene-NAPL by the co-injection process of ethanol and air was also verified within the soilcolumn system. However, the co-injection process of Tert-butanol (TBA) and air showed no enhancement of benzene-NAPL removal. This study found that the viscous pressure of TBA was so higher than the capillary pressure and TBA easily displaced the benzene-NAPL and air present in soil pores. Air of the coinjection process did not work for NAPL removal but hindered NAPL mobilization. NAPL partitioning property and viscous pressure of cosovlent should be considered for application of the co-injection process of cosolvent and air.

Development of Actual Measurement Spacing Factor Using Spacing Data of Air Void in Concrete (콘크리트의 공극 간격 데이터를 활용한 실측간격계수 개발)

  • Lee, Jin-Bum;Jeon, Sung-Il;Kwon, Soo-Ahn;An, Ji-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.701-709
    • /
    • 2011
  • One of the typical evaluation models of concrete air-void system is spacing factor (SF), which was suggested by Power. Power Spacing Factor (PSF) has a disadvantage of the result being different from the actual case due to the existence of entrapped air, because PSF uses average single spacing factor. Therefore, the Actual Measurement Spacing Factor (AMSF) using actually measured data of air void spacing was developed from this study. PSF and AMSF were compared and evaluated in this study by using the image analysis test result of concrete mixture. This study results showed that PSF and AMSF are generally similar, but AMSF had a larger value when PSF was greater than $400{\mu}m$. The results indicated a possibility of PSF giving false measurement estimation where the measurement is less than the actual value in the concrete mixture containing less air. Also, in the result of PSF and AMSF analysis according to the existence of entrapped air, AMSF showed a larger value in the analysis without entrapped air. But PSF showed a smaller value in the analysis without entrapped air, which was different from the actual case. Because PSF used average single spacing factor, it tended to give a false result. The study results showed that AMSF gave more accurate analysis results.

Thermal and Fluid Analyses of Inner Air at Decomposition Equipment on the Waste Gas of Perfluorinated Compounds (과불화 화합물 폐가스에 대한 분해 장치에서의 내부 공기의 열유동해석)

  • You, Jeong-Bong;Kim, Young-Chun;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1375-1380
    • /
    • 2015
  • Nowadays, the technique to deal with the waste gas of perfluorinated compounds using plasma has been developed. As the effective decomposition techniques at many research centers and companies were investigated at home and abroad, the products have been improved with various methods. This study aims to guess the distributions of pressure and temperature through the thermal and fluid analyses inside the decomposition equipment model of waste gas. As the analysis result, the maximum pressure and the minimum pressure are 0.975Pa and -1.037Pa individually on the whole. It is shown that the pressure of air decreases gradually as the air flows from inlet to plane 1 and the pressure increases as the air flows from plane 1 to outlet. And the maximum temperature and the mimum temperature are $1718^{\circ}C$$26.07^{\circ}C$ individually on the whole. It is shown that the temperature of air increases gradually as the air flows from inlet to plane 4 and the temperature decreases as the air flows until outlet. It is thought that the data necessary to develop the real system can be applied by using the thermal and fluid analyses.