• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.034 seconds

Analysis of the Cold Air Flow in Suwon for the Application of Urban Wind Corridor (도시 바람길 활용을 위한 수원시 찬공기 유동 분석)

  • CHA, Jae-Gyu;CHOI, Tae-Young;KANG, Da-In;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.24-38
    • /
    • 2019
  • Due to the dramatic spatial changes caused by industrialization, environmental problems such as air pollution and urban heat island phenomenon, etc. are occurring in cities. In this case, the wind corridor, which is a passage through which fresh and cool air generated in forests outside cities move to the downtown, can be used as a spatial planning method for improving urban environmental problems. Cold air is determined by the characteristics of the flow depending on the topography and land use of cities, and based on this, the medium- and long-term plan should be established. Therefore, this study analyzed the flow of cold air at night through the KLAM_21 model in Suwon-si, Gyeonggi-do, to prepare the basic data required to apply the wind corridors. As a result, it turned out that cold air of Suwon-si was mainly generated from Gwanggyo Mountain that is a large mountain area in the north, and flowed into the urbanization promotion area, and about three hours after sunset, cold air flowed into the downtown. By district, the depth, wind speed, and direction of the cold air layer were formed differently according to the characteristics of the topography and land use. In the areas where large forests were adjacent, the flow of cold air was active. There are three main wind corridors where cold air flows to the downtown of Suwon-si, all of which are formed around rivers. Especially, if the connection between rivers and the surrounding green areas is high, the effect of wind corridors is found to be significant. In order to utilize the wind corridors of Suwon-si, based on the results of this study, it is necessary to make climate maps through actual survey and complex analysis of cold air flow and establish mid-to-long-term plans for the conservation and expansion of major wind corridors.

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

A Study for Estimation of High Resolution Temperature Using Satellite Imagery and Machine Learning Models during Heat Waves (위성영상과 머신러닝 모델을 이용한 폭염기간 고해상도 기온 추정 연구)

  • Lee, Dalgeun;Lee, Mi Hee;Kim, Boeun;Yu, Jeonghum;Oh, Yeongju;Park, Jinyi
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1179-1194
    • /
    • 2020
  • This study investigates the feasibility of three algorithms, K-Nearest Neighbors (K-NN), Random Forest (RF) and Neural Network (NN), for estimating the air temperature of an unobserved area where the weather station is not installed. The satellite image were obtained from Landsat-8 and MODIS Aqua/Terra acquired in 2019, and the meteorological ground weather data were from AWS/ASOS data of Korea Meteorological Administration and Korea Forest Service. In addition, in order to improve the estimation accuracy, a digital surface model, solar radiation, aspect and slope were used. The accuracy assessment of machine learning methods was performed by calculating the statistics of R2 (determination coefficient) and Root Mean Square Error (RMSE) through 10-fold cross-validation and the estimated values were compared for each target area. As a result, the neural network algorithm showed the most stable result among the three algorithms with R2 = 0.805 and RMSE = 0.508. The neural network algorithm was applied to each data set on Landsat imagery scene. It was possible to generate an mean air temperature map from June to September 2019 and confirmed that detailed air temperature information could be estimated. The result is expected to be utilized for national disaster safety management such as heat wave response policies and heat island mitigation research.

Condensation processes in transonic two-phase flows of saturated humid air using a small-disturbance model (미교란 모델을 이용한 포화 습공기 천음속 2상 유동에서의 응축현상)

  • Lee, Jang-Chang;Zvi Rusak
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.23-29
    • /
    • 2003
  • Transonic two-phase flow of Saturated humid air, in which relative humidity is 100%, with various condensation processes around thin airfoils is investigated. The study uses an extended transonic small-disturbance(TSD) model of Rusak and Lee [11, 12] which includes effects of heat addition to the flow due to condensation. Two possible limit types of condensation processes are considered. In the nonequilibrium and homogeneous process, the condensate mass fraction is calculated according to classical nucleation and droplet growth rate models. In the equilibrium process, the condensate mass fraction is calculated by assuming an isentropic process. The flow and condensation equations are solved numerical1y by iterative computations. Results under same upstream conditions describe the flow structure, field of condensate, and pressure distribution on airfoil's surfaces. It is found that flow characteristics, such as position and strength of shock waves and airfoil’s pressure distribution, are different for the two condensation processes. Yet, in each case, heat addition as a result of condensation causes significant changes in flow behavior and affects the aerodynamic performance of airfoils.

Effect of Soil Structure on Soil-Water Characteristic in Unsaturated Soil (불포화토에서 흙의 구조가 흙-함수특성에 미치는 영향)

  • Hwang, Woong-Ki;Kang, Ki-Min;Kim, Tae-Hyung;Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.33-42
    • /
    • 2012
  • The purpose of this study is to determine the effect of soil grain size and its distribution on soil-water characteristic. To do this, soil-water characteristic tests were conducted on Saemangeum silt using the axis translation technique. For comparison, the test was also conducted on Jumunjin sand. Using the test results, the soil-water characteristic curves (SWCCs) of Saemangeum silt and Jumunjin sand were predicted by Van Genuchten model. By comparison and analysis between two SWCCs, the silt shows higher values of matric suction, water content, and air entry value than the sand. On the other hand, the sand has higher values of Van Genuchten model parameters of ${\alpha}$, $n$, $m$ than the silt. It indicates that the SWCC is significantly dependent on the structure of soils. In other words, if a soil has relatively high grain size and poor grain size distribution curve, the values of saturated volumetric water content, residual volumetric water content, and air entry value are small, and the variation of volumetric water content is high in accordance with the matric suction variation, and consequently it shows a narrow range of funicular region.

Estimation of Overall Heat Transfer Coefficient for Single Layer Covering in Greenhouse (일중 피복온실의 관류열전달계수 산정)

  • Hwang, Young-Yun;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 2013
  • This study was conducted to suggest a model to calculate the overall heat transfer coefficient of single layer covering for various greenhouse conditions. There was a strong correlation between cover surface temperature and inside air temperature of greenhouse. The equations to calculate the convective and radiative heat transfer coefficients proposed by Kittas were best fitted for calculation of the overall heat transfer coefficient. Because the coefficient of linear regression between the calculated and measured cover surface temperature was founded to 0.98, the slope of the straight line is 1.009 and the intercept is 0.001, the calculation model of overall heat transfer coefficient proposed by this study is acceptable. The convective heat transfer between the inner cover surface and the inside air was greater than the radiative heat transfer, and the difference increased as the wind speed rose. The convective heat transfer between the outer cover surface and the outside air was less than the radiative heat transfer for the low wind speed, but greater than for the high wind speed. The outer cover convective heat flux increased proportion to the inner cover convective heat flux linearly. The overall heat transfer coefficient increased but the cover surface temperature decreased as the wind speed increased, and the regression function was founded to be logarithmic and power function, respectively.

Simulation Model for Estimating Soil Temperature under Mulched Condition (멀칭에 따른 지온변화 모델의 작성 및 토양온도의 추정)

  • Cui RiXian;Lee Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • A numerical model using soil surface energy balance and soil heat flow equations to estimate mulched soil temperature was developed. The required inputs data include weather data, such as global solar radiation, air temperature, wind speed, atmospheric water vapor pressure, the optical properties of mulching material, and soil physical properties. The observed average soil temperature at 50 cm depth was used as the initial value of soil temperature at each depth. Soil temperature was simulated starting at 0 hour at an interval of 10 minutes. The model reliably described the variation of soil temperature with time progress and soil depth. The correlation between the estimated and measured temperature yielded coefficient values of 0.961, 0.966 for 5cm and 10cm depth of the bare soil, respectively, 0.969, 0.965 for the paper mulched soil, and 0.915, 0.938 for the black polyethylene film mulched soil. The percentages of absolute differences less than 2$^{\circ}$C between soil temperatures measured and simulated at 10 minute interval were 97.4% and 98.5% for 5 cm and 10cm for the bare soil, respectively, and 95.8% and 97.4% for the paper mulched soil, and 70.1% and 92.5% for the polyethylene film mulched soil. The results indicated that the model was able to predict the soil temperature fairly well under mulched condition. However, in the night time, the model performance was a little poor as compared with day time due to the difficulty of accurate determination of the atmospheric long wave radiation.

  • PDF

Development of Early Forecasting System using GIS and Prediction Model related to the Cyanobacterial Blooming in the Daecheong Reservoir of Korea (예보모델과 GIS를 기반한 대청호의 남조류 발생에 대한 조기예보시스템 개발)

  • Kim, Man-Kyu;Park, Jong-Chul;Kim, Kwang-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.2
    • /
    • pp.91-102
    • /
    • 2007
  • To anticipate and respond to harmful algae produced in a big artificial lake like Daecheong reservoir, development of a regional analysis computer system using GIS or RS technique is needed in addition to biological and chemical research. The purpose of this study is to develop a cyanobacterial blooming prediction model to prevent harmful algae produced in Daecheong reservoir and construct an early forecasting system based on GIS. For this purpose this paper examines previous studies related to the relationship between cyanobacteria and environmental factors in Daecheong reservoir and selects precipitation and air temperature as two important environmental factors for the development of cyanobacterial blooming prediction model. Data used in this study are water quality and weather data for three water regions in Daecheong reservoir between 2000 and 2004. Based on qualitative correlation analysis between cyanobacteria and environmental factors, this paper presents a Rump model which enables us to predict cyanobacteria in water regions of Daecheong reservoir. Under this model the prediction of initial occurrence time and growth period of cyanobacteria are possible. The model is also applied to the GIS-based early forecasting system for cyanobacteria, and finally a GIS which can predict cyanobacteria produced in Daecheong reservoir and can manage the related data is developed.

  • PDF

Revised Crackling Core Model Accounting for Fragmentation Effect and Variable Grain Conversion Time : Application to UO2 Sphere Oxidation (파편화 효과와 결정립 가변 전환시간을 고려한 Crackling Core Model의 개선 : UO2 구형 입자의 산화거동으로의 적용)

  • Lee, Ju Ho;Cho, Yung-Zun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.411-420
    • /
    • 2018
  • This study presents a revised crackling core model for the description of $UO_2$ sphere oxidation in air atmosphere. For close reproduction of the sigmoid behavior exhibited in $UO_2$ to $U_3O_8$ conversion, the fragmentation effect contributing to the increased reactive surface area and the concept of variable grain conversion time were considered in the model development. Under the assumptions of two-step successive reaction of $UO_2{\rightarrow}U_3O_7{\rightarrow}U_3O_8$ and final grain conversion time equivalent to ten times the initial grain conversion time, the revised model showed good agreement with the experimental data measured at 599 - 674 K and a lowest deviation when compared with Nucleation and Growth model and AutoCatalytic Reaction model. The evaluated activation energy at 100% conversion to $U_3O_8$, $57.6kJ{\cdot}mol^{-1}$, was found to be closer to the experimentally extrapolated value than to the value determined in AutoCatalytic Reaction model, $48.6kJ{\cdot}mol^{-1}$.