• Title/Summary/Keyword: AHRS

Search Result 72, Processing Time 0.025 seconds

Performance Improvement of an AHRS for Motion Capture (모션 캡쳐를 위한 AHRS의 성능 향상)

  • Kim, Min-Kyoung;Kim, Tae Yeon;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1167-1172
    • /
    • 2015
  • This paper describes the implementation of wearable AHRS for an electromagnetic motion capture system that can trace and analyze human motion on the principal nine axes of inertial sensors. The module provides a three-dimensional (3D) attitude and heading angles combining MEMS gyroscopes, accelerometers, and magnetometers based on the extended Kalman filter, and transmits the motion data to the 3D simulation via Wi-Fi to realize the unrestrained movement in open spaces. In particular, the accelerometer in AHRS is supposed to measure only the acceleration of gravity, but when a sensor moves with an external linear acceleration, the estimated linear acceleration could compensate the accelerometer data in order to improve the precision of measuring gravity direction. In addition, when an AHRS is attached in an arbitrary position of the human body, the compensation of the axis of rotation could improve the accuracy of the motion capture system.

A Study on Attitude Heading Reference System Based Micro Machined Electro Mechanical System for Small Military Unmanned Underwater Vehicle

  • Hwang, A-Rom;Yoon, Seon-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.522-526
    • /
    • 2015
  • Generally, underwater unmanned vehicle have adopted an inertial navigation system (INS), dead reckoning (DR), acoustic navigation and geophysical navigation techniques as the navigation method because GPS does not work in deep underwater environment. Even if the tactical inertial sensor can provide very detail measurement during long operation time, it is not suitable to use the tactical inertial sensor for small size and low cost UUV because the tactical inertial sensor is expensive and large. One alternative to INS is attitude heading reference system (AHRS) with the micro-machined electro mechanical system (MEMS) inertial sensor because of MEMS inertial sensor's small size and low power requirement. A cost effective and small size attitude heading reference system (AHRS) which incorporates measurements from 3-axis micro-machined electro mechanical system (MEMS) gyroscopes, accelerometers, and 3-axis magnetometers has been developed to provide a complete attitude solution for UUV. The AHRS based MEMS overcome many problems that have inhibited the adoption of inertial system for small UUV such as cost, size and power consumption. Several evaluation experiments were carried out for the validation of the developed AHRS's function and these experiments results are presented. Experiments results prove the fact that the developed MEMS AHRS satisfied the required specification.

Development of Rotational Motion Estimation System for a UUV/USV based on TMS320F28335 microprocessor

  • Tran, Ngoc-Huy;Choi, Hyeung-Sik;Kim, Joon-Young;Lee, Min-Ho
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.4
    • /
    • pp.223-232
    • /
    • 2012
  • For the accurate estimation of the position and orientation of a UUV (unmanned underwater vehicle), a low-cost AHRS (attitude heading reference system) was developed using a low-cost IMU (inertial measurement unit) sensor which provides information on the 3D acceleration, 3D turning rate and 3D earth-magnetic field data in the object coordinate system. The main hardware system is composed of an IMU sensor (ADIS16405) and TMS320F28335, which is coded with an extended kalman filter algorithm with a 50-Hz sampling frequency. Through an experimental gimbal device, good estimation performance for the pitch, roll, and yaw angles of the developed AHRS was verified by comparing to those of a commercial AHRS called the MTi system. The experimental results are here presented and analyzed.

Design and Testing of integrated MEMS GPS/AHRS navigation system (MEMS 센서를 이용한 GPS/AHRS 결합 항법 시스템 설계 및 평가)

  • Hong, Jin-Seok;Kim, Seong-Jung;Jeong, Hak-Yeong;Lee, Hyeon-Cheol
    • 한국항공운항학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.302-307
    • /
    • 2004
  • 무인 항공기는 지상 조종 또는 자동 비행으로 원격제어, 각종 정찰, 수송, 및 공격 등의 다양한 임무를 수행할 수 있는 비행체 및 이를 포함한 시스템을 의미한다. 무인기의 자율 운항을 위해서는 위치, 속도 및 자세 등의 항법 정보를 제공하는 항법 시스템이 반드시 필요하며 크기가 작은 무인기를 위해서는 탑재체의 중량이 적은 항법 시스템이 반드시 필요하다. 최근에는 반도체 MEMS 기술을 이용한 저가형 관성 센서들이 많이 개발 되고 있으며 이를 이용한 소형, 저전력, 고정밀 항법 시스템들이 많이 연구 개발되고 있다. GPS/AHRS 결합 시스템은 자세각, 각속도, 가속도 정보 및 GPS를 이용한 위치, 슥도 정보 제공이 가능한 시스템으로 비행체의 자율비행을 위한 정보 제공이 가능한 시스템이다. 본 논문에서는 MEMS 센서를 기반으로한 GPS/AHRS 결합 항법 시스템 설계하고 차량을 이용하여 성능을 평가한 결과를 보여준다.

  • PDF

Dynamic Position of Vehicles using AHRS IMU Sense (AHRS IMU 센서를 이용한 이동체의 동적 위치 결정)

  • Back Ki-Suk;Lee Jong-Chool;Hong Soon-Hyun;Cha Sung-Yeoul
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.77-81
    • /
    • 2006
  • GPS cannot determine random errors such as multipath and signal cutoff caused by surrounding environment that determines the visibility of satellites and the speed of data creation and transmission is lower than the speed of vehicles, it is difficult to determine accurate dynamic positions. Thus this study purposed to implement a method of deciding the accurate dynamic position of vehicles by combining AHRS (Attitude Heading Reference System) IMU (Initial Measurement Unit) based on low-priced MEMS (Micro Electro Mechanical System) in order to provide the information of attitude, position and speed at a high transmission rate without external help. This study conducted an initialization test to decide dynamic position using AHRS IMU sensor, and derived attitude correction angles of vehicles against time through regression analysis. The roll angle was $y=(A{\times}10^{-6})x^2 -(B{\times}10^{-5})x+Cr{\times}10^{-2}$ and the pitch angle was $y=(A{\times}10^{-6})x^2-(B{\times}10^{-7})x+C{\times}10^{-2}$, each of which was derived from second-degree polynomial regression analysis. It was also found that the heading angle was stabilized with variation less than $1^{\circ}$ after 60 seconds.

  • PDF

A Sequential Orientation Kalman Filter for AHRS Limiting Effects of Magnetic Disturbance to Heading Estimation

  • Lee, Jung Keun;Choi, Mi Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1675-1682
    • /
    • 2017
  • This paper deals with three dimensional orientation estimation algorithm for an attitude and heading reference system (AHRS) based on nine-axis inertial/magnetic sensor signals. In terms of the orientation estimation based on the use of a Kalman filter (KF), the quaternion is arguably the most popular orientation representation. However, one critical drawback in the quaternion representation is that undesirable magnetic disturbances affect not only yaw estimation but also roll and pitch estimations. In this paper, a sequential direction cosine matrix-based orientation KF for AHRS has been presented. The proposed algorithm uses two linear KFs, consisting of an attitude KF followed by a heading KF. In the latter, the direction of the local magnetic field vector is projected onto the heading axis of the inertial frame by considering the dip angle, which can be determined after the attitude KF. Owing to the sequential KF structure, the effects of even extreme magnetic disturbances are limited to the roll and pitch estimations, without any additional decoupling process. This overcomes an inherent issue in quaternion-based estimation algorithms. Validation test results show that the proposed method outperforms other comparison methods in terms of the yaw estimation accuracy during perturbations and in terms of the recovery speed.

Bias Estimation of Magnetic Field Measurement by AHRS Using UKF (UKF를 사용한 AHRS의 자기장 측정 편차 추정)

  • Ko, Nak Yong;Song, Gyeongsub;Jeong, Seokki;Lee, Jong-Moo;Choi, Hyun-Taek;Moon, Yong Seon
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2017
  • This paper describes an unscented Kalman filter approach to estimate the bias in magnetic field measurements. A microelectromechanical systems attitude heading reference system (MEMS AHRS) was used to measure the magnetic field, together with the acceleration and angular rate. A magnetic field is usually used for yaw detection, while the acceleration serves to detect the roll and pitch. Magnetic field measurements are vulnerable to distortion due to hard-iron effect and soft-iron effect. The bias in the measurement accounts for the hard-iron effect, and this paper focuses on an approach to estimate this bias. The proposed method is compared with other methods through experiments that implement the navigation of an underwater robot using an AHRS and Doppler velocity log. The results verify that the compensation of the bias by the proposed method improves the navigation performance more than or comparable to the compensation by other methods.

Sampled-data Fuzzy Observer Design for an Attitude and Heading Reference System and Its Experimental Validation

  • Kim, Han Sol;Park, Jin Bae;Joo, Young Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2399-2410
    • /
    • 2017
  • In this paper, a linear matrix inequality-based sampled-data fuzzy observer design method is proposed based on the exact discretization approach. In the proposed design technique, a numerically relaxed observer design condition is obtained by using the discrete-time fuzzy Lyapunov function. Unlike the existing studies, the designed observer is robust to the uncertain premise variable because the fuzzy observer is designed under the imperfect premise matching condition, in which the membership functions of the system and observer are mismatched. In addition, we apply the proposed method to the state estimation problem of the attitude and heading reference system (AHRS). To do this, we derive a Takagi-Sugeno fuzzy model for the AHRS system, and validate the proposed method through the hardware experiment.

Multi-Attitude Heading Reference System-based Motion-Tracking and Localization of a Person/Walking Robot (다중 자세방위기준장치 기반 사람/보행로봇의 동작추적 및 위치추정)

  • Cho, Seong Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.1
    • /
    • pp.66-73
    • /
    • 2016
  • An Inertial Measurement Unit (IMU)-based Attitude and Heading Reference System (AHRS) can calculate attitude and heading information with long-term accuracy and stability by combining gyro, accelerometer, and magnetic compass signals. Motivated by this characteristic of the AHRS, this paper presents a Motion-Tracking and Localization (MTL) method for a person or walking robot using multi-AHRSs. Five AHRSs are attached to the two calves, two thighs, and waist of a person/walking robot. Joints, links, and coordinate frames are defined on the body. The outputs of the AHRSs are integrated with link data. In addition, a supporting foot is distinguished from a moving foot. With this information, the locations of the joints on the local coordinate frame are calculated. The experimental results show that the presented MTL method can track the motion of and localize a person/walking robot with long-term accuracy in an infra-less environment.

Physicochemical Properties and Antioxidant Activities of Steam-Dried Allium hookeri Root (증포 처리한 삼채 뿌리의 이화학적 특성 및 항산화 활성)

  • Jun, Hyun-Il;Jang, Ha-Na;Yang, Jae-Heon;Song, Geun-Seoup;Kim, Young-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.3
    • /
    • pp.412-417
    • /
    • 2015
  • This study was carried out to investigate the effect of steam-drying method on physicochemical properties and antioxidant activities of Alliun hookeri root (AHR). Moisture, crude protein, crude fat, and crude ash contents of raw and steam-dried AHRs were 10.91~14.15%, 11.14~13.49%, 0.83~3.02%, and 7.55~8.98%, respectively. Sulfur contents of steam-dried AHRs were 2.0 and 2.2 times lower than that of raw AHR (0.51%), respectively. pH and total sugar contents of AHRs were reduced by steam-drying, whereas titrate acidity and browning intensity were increased. The L and b values of AHRs in Hunter's value were also reduced, but a value was increased by steam-drying. Among hot water extracts from raw and steam-dried AHRs, four times steam-drying showed the lowest $EC_{50}$ values (0.44, 9.01, and 0.48 mg/mL, respectively) in DPPH radical assay, ABTS radical assay, and reducing power, whereas four times steam-drying had the highest total phenolic content ($34.47{\mu}g/mg$) and browning intensity (2.05 and 0.20 at 280 and 420 nm, respectively). The antioxidant activities of hot water extracts from raw and steam-dried AHRs were closely correlated with their total phenolic contents and browning intensity, showing coefficient of determination ($R^2$) values higher than 0.87. From the results, we suggest that steam-drying method could be used as an effective process for increasing the antioxidant activity of AHR.