• Title/Summary/Keyword: AGREE

Search Result 2,611, Processing Time 0.032 seconds

A Study on Ensuring Biosafety of Biotechnology Product under Debate about Trade and the Environment (DDA 무역-환경 논의와 생명공학제품의 안전성 확보)

  • Sung, Bong-Suk;Yoon, Ki-Kwan
    • Environmental and Resource Economics Review
    • /
    • v.13 no.3
    • /
    • pp.519-547
    • /
    • 2004
  • This paper analyze problems about scope of specific trade obligations(STOs), principle of dispute settlement procedure, and non-parties in context of the Cartagena Protocol on Biosafety(POB), which based on sub-paragraph 31(i) of DDA WTO Ministrial Declaration. The implications based on result of this study are as follows. First, to accept the wider scope of STOs under POB in Korea, importing country, won't be harmful to LMOs and Bioindustry. Instead, it will ensure a high level of biosafety concerning the import of LMOs. Exporters can take different kinds of trade measures to countervail adverse effect on the export of LMOs in this case. Therefore importer will endure the aftereffect. However, if korea were in exporter's place, to accept the wider scope STOs under POB will not have a good influence on the export of LMOs. Korea, therefore, should devise scheme for responding to debate about the STOs in MEAs, which have to be based on cost-benefit analysis and scenarios taking into account of speed and level in biotechology progress, status and trend of LMOs R&D and production, and condition of other industries. Second, it is not easy to agree with applying to what's rule between the POB and WTO for settlement dispute. Because there is the incompatibility between the POB characterized according to social rationality and WTO's rules for safety and environmental protection characterized according to scientific rationality. This issue have to be discussed for long period due to gap like that. Accordingly Korea, one of major LMOs importing countries, should suggest continuously that the effort is needed to ensure an adequate level of protection in transboundary movements of LMOs and scientific, environmental and socio-economic study. Third, in case of dispute between party and non-party of the POB, the duties under the WTO of non-party of the POB(if WTO member country) is valid. The country, therefore, will try to settle dispute based on WTO's rules. However, international society have to ensure for sound and safe use of LMOs in the field of transboundary movements. Accordingly Korea should devise scheme for preventing the possibility of dispute between party and non-party of the POB(if WTO member country), which is supported by policy options under the POB.

  • PDF

Oxidative Degradation of PCE/TCE Using $KMnO_4$ in Aqueous Solutions under Steady Flow Conditions (유동조건에서 $KMnO_4$도입에 따른 수용액중 PCE/TCE의 산화분해)

  • Kim, Heon-Ki;Kim, Tae-Yun
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.685-693
    • /
    • 2008
  • The rates of oxidative degradation of perchloroethene (PCE) and trichloroethene (TCE) using $KMnO_4$ solution were evaluated under the flow condition using a bench-scale transport experimental setup. Parameters which are considered to affect the reaction rates tested in this study were the contact time (or retention time), and the concentration of oxidizing agent. A glass column packed with coarse sand was used for simulating the aquifer condition. Contact time between reactants was controlled by changing the flow rate of the solution through the column. The inflow concentrations of PCE and TCE were controlled constant within the range of $0.11{\sim}0.21\;mM$ and $1.3{\sim}1.5\;mM$, respectively. And the contact time was $14{\sim}125$ min for PCE and $15{\sim}36$ min for TCE. The $KMnO_4$ concentration was controlled constant during experiment in the range of $0.6{\sim}2.5\;mM$. It was found that the reduction of PCE and TCE concentrations were inversely proportional to the contact time. The exact reaction order for the PCE and TCE degradation reaction could not be determined under the experimental condition used in this study. However, the estimated reaction rate constants assuming pseudo-1st order reaction agree with those reported based on batch studies. TCE degradation rate was proportional to $KMnO_4$ concentration. This was considered to be the result of using high inflow concentrations of reactant, which might be the case at the vicinity of the source zones in aquifer. The results of this study, performed using a dynamic flow system, are expected to provide useful information for designing and implementing a field scale oxidative removal process for PCE/TCE-contaminated sites.

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

A Study on the Calculation of Evapotranspiration Crop Coefficient in the Cheongmi-cheon Paddy Field (청미천 논지에서의 증발산량 작물계수 산정에 관한 연구)

  • Kim, Kiyoung;Lee, Yongjun;Jung, Sungwon;Lee, Yeongil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.883-893
    • /
    • 2019
  • In this study, crop coefficients were calculated in two different methods and the results were evaluated. In the first method, appropriateness of GLDAS-based evapotranspiration was evaluated by comparing it with observed data of Cheongmi-cheon (CMC) Flux tower. Then, crop coefficient was calculated by dividing actual evapotranspiration with potential evapotranspiration that derived from GLDAS. In the second method, crop coefficient was determined by using MLR (Multiple Linear Regression) analysis with vegetation index (NDVI, EVI, LAI and SAVI) derived from MODIS and in-situ soil moisture data observed in CMC, In comparison of two crop coefficients over the entire period, for each crop coefficient GLDAS Kc and SM&VI Kc, shows the mean value of 0.412 and 0.378, the bias of 0.031 and -0.004, the RMSE of 0.092 and 0.069, and the Index of Agree (IOA) of 0.944 and 0.958. Overall, both methods showed similar patterns with observed evapotranspiration, but the SM&VI-based method showed better results. One step further, the statistical evaluation of GLDAS Kc and SM&VI Kc in specific period was performed according to the growth phase of the crop. The result shows that GLDAS Kc was better in the early and mid-phase of the crop growth, and SM&VI Kc was better in the latter phase. This result seems to be because of reduced accuracy of MODIS sensors due to yellow dust in spring and rain clouds in summer. If the observational accuracy of the MODIS sensor is improved in subsequent study, the accuracy of the SM&VI-based method will also be improved and this method will be applicable in determining the crop coefficient of unmeasured basin or predicting the crop coefficient of a certain area.

Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block (다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교)

  • Lee Sang Wook;Oh Young Tack;Kim Woo Cheol;Keum Ki Chang;Yoon Seong Ick;Kim Hyun Soo;Park Won;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.391-396
    • /
    • 1995
  • Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from $80{\%}$ to $20{\%}$ isodose lines and $90{\%}$ to $10{\%}$ were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. Results : Increasing MLC angle ($0-75^{\circ}$) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from $80{\%}$ to $20{\%}$ isodose lines, while being the small increase of penumbra width from $90{\%}$ to $10{\%}$ isodose line varing the depth and energy. The effective penumbra width of lead alloy block are agree resonably with those of MLC within 4.8mm. Conclusion : The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.

  • PDF

A Study on the Experience of Physical Therapy Accident in The Physiotherapist (물리치료사에 있어서 물리치료 사고의 경험에 관한 연구)

  • Kim, Jong-Dae
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.69-80
    • /
    • 2002
  • The objective of research provides the physical therapy of good quality to the patients to search for the problem pant against a physical therapy accident and it simultaneously respects physical therapy company law, the possibility of preparing a system defensive ability in order to be. The data were collected from 2000 October 1 to December 30th, and analyzed by a frequency and a percentage, oneway ANOVA, Scheffe method, $x^2$ official approvals. Conclusion (1) the accident where the patient falls from inside the treatment 'room is many and occasionally' 29.3% (63 people) with was many most. (2) Because of a mistake by a part-time therapist in holiday or a colleague therapist to do, the fracture or bum accident happens 12.5% (27 people), by a assist nurse due to more showed 12.1% (26 people) experience degree in the patient. (3) From physical therapy process breakdown of the medical treatment machinery and tools or it is in malfunction to do and the experience which has a failure to physical therapy is one enemy 68.1% (147 people) was in item. Also it treats and the patient or in the protector it sends an explanation in advance not to be, the experience which it enforces 50% (108 people), of service hour treatment equipment the medical treatment directives broad way of the doctor is accurate in insufficiency and does not enforce the experience is 45.4% (98 people), the patient whom I am treating Hot Pack (electricity has pack inclusion) with to do, the art dealer (over at 1 buffoonery) the experience which it puts on 27.1% (58 people), The patient whom I am treating is the electrotherapy flag (electricity has pack exclusion) with to do, the art dealer (1 degree art dealer over) the experience which it puts on 16.3% (35 people), the experience boat song the patient against a fracture from physical therapy process 9 person (4.2%) was visible an experience degree. (4) With hospital infection to do, from the patient the experience and the therapist which receive a problem proposal were caused by with hospital infection and the answer back regarding the experience which tries to receive a treatment appeared 6% (13 people), 42% (9 people) with each. (5) It listened to the treatment hour patient or the appeal of the protector and especially it does not appear to be being important it was not and and the management which is special it did not take, also the experience where the condition of the patient is deteriorated after that was 10.3% (22 people). (6) The condition or state of the patient does not agree with the medical treatment instruction of the doctor not to be, amendment one experience was 67.5% (145 people). (7) The experience degree of the physical therapy accident which relates with physical therapy recording and a secret maintenance 59.7% (129 people) 'is many and occasionally it is,' it showed an answer back and e it showed a most high accident experience degree. (8) The business overweight of physical therapy company 43.3% (93 people) with was high most from recognition degree of the physical therapy company against a physical therapy accident. (9) Against the question which asks the responsibility subject matter of physical therapy accident the whole answer back volition 42.8% did it is a joint responsibility where the multi person relates. (10) The accident occurs most the hour unit which plentifully in the afternoon 64.3% (133 people) with appeared from the recognition degree against the frequency hour unit of physical therapy accident. (11) Physical therapy it bought and after the various medical treatment accident which relates against the attitude of the, patient side against the physical therapy company it understood and trillion it was many most with 33.3% to be finished. (12) After physical therapy accident the management against the physical therapy company of the hospital authorities concerned above all do not experience 70.6% (149 people), from event right and wrong submission 22.7% (48 people), warning management 2.8% (6 people), the event report requirement and money compensation were each 0.5% (1 person). (13) As the prevention book of physical therapy accident most it is important, the fact which it thinks that, the persons supplement of physical therapy company 58.8% (127 people) with was high most. (14) It related with a physical therapy accident and the medical law 43.5%, civil law 23.9%, was visible the answer back ratio of the criminal law 13.7% from the degree which probably is a relation law.

  • PDF

Assessment of the Effect of a Public Health Clinics' Home-Based Terminal Cancer Patient Management in Collaboration with a Regional Cancer Center (경남 지역 암센터와 보건소 재가암환자 관리 서비스와의 연계 사업)

  • Song, Haa-Na;Kang, Myoung Hee;Lee, Gyeong Won;Kim, Hoon Gu;Lee, Won Sup;Kang, Jung Hun;Kang, Yoon Sik;Eun, Young
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.1
    • /
    • pp.10-19
    • /
    • 2013
  • Purpose: Home-based care providers were surveyed to assess the effect of collaborative service between Gyeongnam Regional Cancer Center (GRCC) and public health centers (PHCs) in Gyeongnam province. Methods: Twenty home-based care providers who had previously participated in the GRCC-PHC care project were recruited from nine PHCs and were surveyed using a questionnaire developed by specialists. Questions were rated using the 5-point Likert scale ranging from "strongly disagree (-2)" to "strongly agree (+2)" and each score was multiplied by the corresponding number of respondents (n=20) with the maximum score of 40. Results: Between January 2008 and December 2011, 73 patients were registered to the collaborative service: 72 by GRCC and one by PHC. Home-based care providers marked the highest score (23 points) to "The collaborative service contributed to patients and their family's psychological stability" and the lowest score (11 points) to "The collaborative service was generally helpful for home-based cancer management." For possible suggestions to improve the service, the highest score (35 points) was given to "Simplification of the hospitalization process" followed by "Substantial benefits for patients at their visit to the hospital" (34 points). Conclusion: The results revealed several limitations of the GRCC-PHC collaborative care service for terminal cancer patients. The service could be further improved by developing measures to address the limitations and a service model tailored to region-specific needs.

THEORETICAL STUDY ON OBSERVED COLOR-MAGNITUDE DIAGRAMS

  • Lee, See-Woo
    • Journal of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.41-70
    • /
    • 1979
  • From $B\ddot{o}hm$-Vitense's atmospheric model calculations, the relations, [$T_e$, (B-V)] and [B.C, (B-V)] with respect to heavy element abundance were obtained. Using these relations and evolutionary model calculations of Rood, and Sweigart and Gross, analytic expressions for some physical parameters relating to the C-M diagrams of globular clusters were derived, and they were applied to 21 globular clusters with observed transition periods of RR Lyrae variables. More than 20 different parameters were examined for each globular cluster. The derived ranges of some basic parameters are as follows; $Y=0.21{\sim}0.33,\;Z=1.5{\times}10^{-4}{\sim}4.5{\times}10^{-3},\;age,\;t=9.5{\sim}19{\times}10^9$ years, mass for red giants, $m_{RG}=0.74m_{\odot}{\sim}0.91m_{\odot}$, mass for RR Lyrae stars, $m_{RR}=0.59m_{\odot}{\sim}0.75m_{\odot}$, the visual magnitude difference between the turnoff point and the horizontal branch (HB), ${\Delta}V_{to}=3.1{\sim}3.4(<{\Delta}V_{to}>=3.32)$, the color of the blue edge of RR Lyrae gap, $(B-V)_{BE}=0.17{\sim}0.21=(<(B-V)_{BE}>=0.18),\;[\frac{m}{L}]_{RR}=-1.7{\sim}-1.9$, mass difference of $m_{RR}$ relative to $m_{RG},(m_{RG}-m_{RR})/m_{RG}=0.0{\sim}0.39$. It was found that the ranges of derived parameters agree reasonably well with the observed ones and those estimated by others. Some important results obtained herein can be summarized as follows; (i) There are considerable variations in the initial helium abundance and in age of globular clusters. (ii) The radial gradient of heavy element abundance does exist for globular clusters as shown by Janes for field stars and open clusters. (iii) The helium abundance seems to have been increased with age by massive star evolution after a considerable amount (Y>0.2) of helium had been attained by the Big-Bang nucleosynthesis, but there is not seen a radial gradient of helium abundance. (iv) A considerable amount of heavy elements ($Z{\sim}10{-3}$) might have been formed in the inner halo ($r_{GC}$<10 kpc) from the earliest galactic co1lapse, and then the heavy element abundance has been slowly enriched towards the galactic center and disk, establishing the radial gradient of heavy element abundance. (v) The final galactic disk formation might have taken much longer by about a half of the galactic age than the halo formation, supporting a slow, inhomogeneous co1lapse model of Larson. (vi) Of the three principal parameters controlling the morphology of C-M diagrams, it was found that the first parameter is heavy clement abundance, the second age and the third helium abundance. (vii) The globular clusters can be divided into three different groups, AI, BI and CII according to Z, Y an d age as well as Dickens' HB types. BI group clusters of HB types 4 and 5 like M 3 and NGC 7006 are the oldest and have the lowest helium abundance of the three groups. And also they appear in the inner halo. On the other hand, the youngest AI clusters have the highest Z and Y, and appear in the innermost halo region and in the disk. (viii) From the result of the clean separations of the clusters into three groups, a three dimensional classification with three parameters, Z, Y and age is prsented. (ix) The anomalous C-M diagrams can be expalined in terms of the three principal parameters. That is, the anomaly of NGC 362 and NGC 7006 is accounted for by the smaller age of the order of $1{\sim}2{\times}10^9$ years rather than by the helium abundance difference, compared with M 3. (x) The difference in two Oosterhoff types I and II can be explained in terms of the mean mass difference of RR Lyrae variables rather than in terms of the helium abundance difference as suggested by Stobie. The mean mass of the variables in Oosterhoff type I clusters is smaller by $0.074m_{\odot}$ which is exactly consistent with Rood's estimate. Since it was found that the mean mass of RR Lyrae stars increases with decreasing Z, the two Oosterhoff types can be explained substantially by the metal abundance difference; the type II has Z<$3.4{\times}10^{-4}$, and the type I has higher Z than the type II.

  • PDF

Study on the Establishment of Project Duty of Water and Facility Capacity in Upland Irrigation - On the Estimation of Duty of Water for the Upland Crops by the Measurement of Evapotranspiration - (밭 관개의 계획용수량 및 시설용량의 정립에 관한 연구 -증발산량 실측에 의한 밭용수량의 추정에 관하여-)

  • 김시원;김선주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.4
    • /
    • pp.23-44
    • /
    • 1988
  • The evaportranspiration of upland crops was measured by four types of lysimeter and water consumption characteristics together with the optimum irrigation point by the crops was defind. Among the evapotranspiration estimation formulas, the constant of wind function in the modified Penman equation was corrected to agree with the meteorological conditions of Korea. The evapotranspiration of the crops in the project standard year was estimated according to the cropping system of the project area in Chungju, and from the estimated evapotras - spiration, net duty of water per one time and irrigation in tervals were investigated. The results obtained are summarized as follows: 1. The evapotranspiration of the same crop measured at the same plot was slightly different by the lysimetric methods, and among the four types of lysimeter, the accuracy of the floating lysimeter was the highest. 2. The yields among the watering treatments showed the significance of 5% in the expe- riment with red cabbage and Chinese cabbage, and significance of 1% in the crisphead lettuce, and the optimum irrigation point for the tested crops was defined ad pF 2.0 by the least squre difference test. 3. The evapotranspiration of the crops in the mid-season stage showed maximum among the growing stages, and the average daily evapotranspiration by the crops over the growing seasons of cabbage, crisphead lettuce, Chinese cabbage, summer cucumber, tornato, salary and autumn cucumber was 4.18mm, 4.77mm, 3.9qrnm, 5.68mnn, joonim, 4.26mm and 3.3qrnn, respectively. 4. From the investigated soil moisture extration pattern(SMEP) of the crisphead lettuce, cucumber and tomato, the proportion of the first layer in the initial stage showed over so%, and the SMEP of the lowest fourth layer during the late-season stage in the experiment cabbage and Chinese cabbage was 15.8% and 16.9, respectively, with showed that the root elongated th the lowest soil layer. 5. The total available moisture(TAM) of clay loam was 21.2-23.3mm and that of sandy loam was 16.1 - 19.0mm under the optimum irrigation point of pF. 2.0, and the total readily available moisture( TRAM) of the crops cultivated in the clay loam soil was larger than that cultivated in the sandy loam soil, and the TRAM during the mid-and late-season were larger than that of the inital and crop development stage. 6. The estimated evapotranspration by the corrected Pennam equation, whkh corrected the constant of the wind function in the modified Penman equation, was nearly agreed with the actually measured evaporanspiration of grass. 7. Among the several evaportranspiration estimation methods, the evapotranspiration es- timated by the corrected Pennam equation was closed to the actual evapotranspiration of reference crop (grass) evapotranspiration, therefore it is suggested to use the corrected Penman equation to determine the duty of water of corps. 8. The average crop coefficient (Kc) of cabbage by the corrected Penman equation was 0.94 and that of crisphead lettuce, summer cucumber, tomato, salary, Chinese cabbage and autumn cucumber was 1.07, 1.22, 1.02, 1.01, 1.35, 1.09, respectively 9. The estimated total evapotranspiration of cabbage in the project area( Chungju) by the corrected Penman equation was 223.9mm and that of crisphead lettuce, Chinese cabbage, summer cucumber, tomato, salary and auturun cucumber was 215.7mm, 205.9mm, 359.Omrn, 300.9mm, 332.lmm and 202.7mm, respectively. 10. The net duty of water per one time of the crops cultivated in the sandy loam soil, and the net duty of water per one time in the mid-season & late-season showed larger than that of the initial stage. 11. The shortest irrigation interval of cabbage in the project area was 4.2 days, and that of crisphead lettuce, Chinese cabbage, cucumber, tomato and salary was 1.2days, 2.3days, 1.8days, 2.2days and 2.7days, respectively.

  • PDF