전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구 (Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography)

  • 김기원;권용락;서승원;권경태;오주영;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.205-211
    • /
    • 2015
  • 복부 전후 방향 검사 시 automatic exposure control (AEC) mode에서 조사시간을 제한하지 않고 검사를 하는 방법 (non-time limit, NTL) 과 조사시간을 제한하고 검사하는 방법 (time limit, TL)에 대해서 영상 품질 평가인 신호 대 잡음비 (signal to noise ratio, SNR), 대조도 대 잡음비 (contrast to ratio, CNR)를 측정하여 TL 방법과 NTL방법을 비교 평가하고자 하였다. 실험 기기는 XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden), Rando Phantom (alderson research laboratories, USA)과 $5.5{\times}9{\times}0.1cm^3$ 크기의 차폐재를 사용하였으며, AEC mode에서 전리함 (ionization chamber)를 상단 2 개만 작동하도록 설정하고 관전압은 80 kVp로 설정하였다. TL 방법의 경우에는 조사시간을 51 msec로 제한하였으며, 전리함에 차폐재를 부착하지 않은 상태와 부착한 상태에서 NTL AEC mode와 TL AEC mode의 영상을 획득하였다. 또한 'Image J"를 이용하여 영상 평가방법인 SNR과 CNR로 평가하였다. 결론적으로 차폐재를 부착했을 때 NTL AEC mode가 다른 실험 방법보다 선량이 최대 130.7% 최소 80%까지 증가한 결과 값을 보였으며, TL AEC mode는 NTL AEC mode보다 mAs와 피폭선량에서 각 각 43.8%, 44.4% 감소한 값을 보였다. 통계적으로는 SNR과 CNR은 유의한 차이를 보이지 않았다($p{\geq}0.05$). 그러므로, 본 연구에서는 BMI 지수가 높은 환자나 수술 후 인체 내에 금속물질이 있는 환자를 검사할 경우에는 TL AEC mode가 유효한 검사법이라고 사료된다.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • 제7권4호
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가 (Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System)

  • 김재겸;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향 (Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode)

  • 정운찬;주영철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

흉부 후·전방향 검사 시 보조관심영역의 변화가 노출지수와 입사표면선량에 미치는 영향 (An Effect to the Exposure Index and Entrance Surface Dose according to the Sub-ROI in Chest PA Radiography)

  • 장용희;안호찬;김한용;김동환;주영철
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.685-691
    • /
    • 2023
  • 본 연구는 흉부 후·전방향 검사 시 보조관심영역의 변화가 노출지수와 선량에 미치는 영향에 대한 연구를 통해, 임상에서 적절한 보조관심영역 적용에 대한 인식을 제고하고자 한다. 본 연구는 흉부 모형 팬텀을 대상으로 하였고, 조사조건은 120 kVp, 200 mA, 2 mAs로 설정하였으며, 조사야 크기는 영상수용체 전체를 포함하는 크기(17 X 17")를 적용했다. Sub-ROI는 장비 제조사에서 제공하는 다섯 가지 방식(AEC, VR, HR, LS, SS)를 이용하였다. Sub-ROI 변화에 따른 EI의 평균값은 AEC의 경우 135.58 ± 0.89, VR은 100.80 ± 0.80, HR은 143.43 ± 0.76, LS는 103.22 ± 0.68, SS는 102.79 ± 0.84로 나타났으며, ESD의 평균값은 AEC의 경우 30.28 ± 0.50 µGy, VR은 30.16 ± 0.44 µGy, HR은 30.30 ± 0.46 µGy, LS는 30.23 ± 0.46 µGy, SS는 30.28 ± 0.51 µGy으로 측정되었다. 본 연구 결과, EI는 제조사에서 권고하는 AEC 모드를 기준으로 VR (25.7%)과 LS (23.9%), SS (24.2%)모드는 감소하였으며, HR 모드는 5.7% 증가하였다. 하지만, ESD는 Sub-ROI 변화에 영향을 받지 않았다. 그러므로 임상에서 Chest PA 검사 시 Sub-ROI에 따라서 EI가 변경될 수 있으니, 임상에서는 이점을 유의하여 검사조건 설정 시 Sub-ROI를 적절하게 사용해야 한다고 사료된다.

조리개형 X선 콜리메이터의 개발에 따른 유용성 평가 (Usability Evaluation by Development of IRIS Type X-ray Collimator)

  • 강인석;박재윤;임청환;최재호;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.249-254
    • /
    • 2018
  • In this study, we evaluated the DAP(Dose Area Product) reduction effect of the newly developed IRIS collimator by measuring the DAP of the Rectangle collimator and the IRIS collimator depending on the field, SID(Source to Image recpetor Distance) change, and AEC mode use. The results were as follows. The IRIS collimator decreased DAP by 34.91, 29.33, and 29.04%, respectively, compared to the Rectangle collimator when the field was increased to $8{\times}8$, $12{\times}12$, $16{\times}16inch$. And also, when the SID was increased to 100, 120 and 140 cm, the IRIS collimator decreased DAP by 10.73, 33.68 and 46.22%, respectively, compared to the Rectangle collimator. In AEC mode and none-AEC mode, DAP in IRIS collimator was reduced by 32.71 and 21.69%, respectively, compared with the Rectangle type. The IRIS collimator can reduce DAP by 29.62% on average compared to Rectangle type, which is statistically significant. These results suggest that the newly developed IRIS collimator can be used in medical field to alleviate radiation exposure.

자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향 (Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode)

  • 김승욱;임청환;주영철;유신영
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.903-909
    • /
    • 2023
  • 본 연구는 자동노출제어장치를 이용한 흉부 측방향 검사 시에 환자의 중심위치 변화가 주변 장기의 피폭선량과 화질에 미치는 영향을 탐구하는데 목적이 있다. 실험은 인체모형팬텀을 대상으로 하였다. 바늘침을 팬텀의 관상선 중심 하단부에 부착하였고, 납 자를 검출기 하단부에 부착하여, 50 cm 지점이 AEC 이온챔버의 중앙 하단부에 위치하도록 하였다. 조사조건은 125 kVp, 320 mA, 초점-영상검출기간 거리는 180 cm, 조사야 크기는 14×17 inch를 사용하였다. AEC 이온 챔버는 중앙-하단 1개만 사용했고, Sensitivity 'Middle', Density '0' 으로 설정하여, 중심 X선은 6번째 흉추를 향해 수직입사 하였다. AEC mode를 적용한 상태에서 바늘침과 납 자의 50 cm 지점이 일치되게 위치시킨 후 팬텀을 배 쪽으로 5 cm (F5), 등 쪽으로 5 cm (B5) 씩 이동시킨 후 ESD를 측정하여 선량 인자를 분석하였다. 환자 중심위치 변화에 따른 갑상선의 ESD는 Center의 경우 232.60±2.20 μGy, F5는 231.22±1.53 μGy, B5는 184.37±1.19 μGy로 나타났으며, 유방의 ESD는 Center의 경우 288.54±3.03 μGy, F5는 260.97±1.93 μGy, B5는 229.80±1.62 μGy, 폐 중심부의 ESD는 Center의 경우 337.02±3.25 μGy, F5는 336.09±2.29 μGy, B5는 261.76±1.68 μGy 로 나타났다. 선량 인자의 각 그룹 간 평균값의 차이를 비교한 결과 통계적으로 유의한 차이가 나타났으며(p<0.01), 각각 독립적인 그룹으로 나타났다. 연구의 결과, 환자 중심위치 변화에 따른 갑상선, 유방, 폐 중심부의 선량의 차이는 환자가 전방 5 cm 정도의 움직임에서는 유방(10%)를 제외한 장기에서는 큰 차이가 없었으나, 후방 5 cm 정도의 움직임에서는 각 부위에서 평균 23.7%의 선량 감소를 나타냈다. 또한, 환자 중심위치가 후방으로 이동 시 화질의 저하가 나타났다.

부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과 (Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus)

  • 정민규;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.

자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

  • 정민규;성열훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.635-642
    • /
    • 2020
  • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.