• Title/Summary/Keyword: ADC2A

Search Result 412, Processing Time 0.044 seconds

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

Implementation of An Automated Ultrasonic Flaw Imaging System for the Inspection of Pipe Welding (배관 용접부 자동 초음파 결함 영상 보정 시스템 구현)

  • Kim, Han-Jong;Park, Jong-Hoon;Kim, Cheol-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.556-559
    • /
    • 2008
  • In this study, an automated ultrasonic testing system and post signal and image processing techniques are developed in order to construct ultrasonic flaw images in weldments. The automated ultrasonic testing system developed in the present study adopted an 8 channel pulser/receiver-ADC unit and a 2 axis motion driving unit and the post signal and image processing algorithms are built into the system program of the automated ultrasonic testing system.

  • PDF

치료중 실시간 모니터링을 위한 투과형 빔측정장치 개발

  • Kim, Jae-Hong;Swanepoel, M.W.;Dekock, E.A.;Park, Yeon-Su;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.315-315
    • /
    • 2010
  • 양성자 빔을 이용하여 두경부 암 치료를 South Africa의 iTHEMBA에서 시행하고 있다. 200 MeV의 양성자 빔라인으로부터 진공에서 대기로 인출하여 노즐을 통과하여 종양세포에 조사된다. 치료계획에 적합하게 빔에너지와 모양을 변환하고, 빔을 모니터링하는 기계적 장치들이 노즐에 구성된다. 빔라인에는 이온챔버, Steering Magnet, Multi-wire 이온챔버, Range trimmer plates, lead scattering plate, Double-wedge energy degrader, Multi-layer Faraday cup, Range modulator, Range monitor, occluding ring, Shielding collimators, Quadrant and monitor ionization chamber, Treatment collimator, 그리고 Wellhofer dosimetry tank로 구성되어 있다. 총길이는 6.6m이며 노즐 끝에서 환자의 isocenter 까지는 30cm 정도 아래에 위치한다. 상기의 배치를 갖는 시스템의 양성자 scattering system의 성능을 MCNPX v2.5.0 Monte Carlo simulation을 실시하였다. 또한 정확한 선량을 실시간으로 측정하는 방법인 투과형 검출기를 개발하여 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF

Application of RF-ID in Subway System (지하철 시스템에 대한 RF-ID의 적용)

  • Lee, Yong-Jea;Kim, Do-Hun;Kim, Yong-Sang;Yim, Sang-Wook;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.402-404
    • /
    • 2003
  • Radio frequency identification (RF-ID) is an automatic data capture (ADC) technology that comprises small data-carrying device(is called Tag) and fixed or mobile device(is called reader). Tags are attached or deattached device. Readers may be installed at locations where data capture is required, and may also be in the form of portable readers. In this paper, we are proposing an application for the subway station using the RF-ID system and a system for the gateless fare collection passing through the booth in only carrying the card. In this system that RF-ID system and Bluetooth are applied. We designed two wireless communication channels. One is the 125kHz communication channel by FSK and PSK for power supplying on the card and identification and the other is 2.4GHz channel for the collection.

  • PDF

Design of 6bit CMOS A/D Converter with Simplified S-R latch (단순화된 S-R 래치를 이용한 6비트 CMOS 플래쉬 A/D 변환기 설계)

  • Son, Young-Jun;Kim, Won;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.11C
    • /
    • pp.963-969
    • /
    • 2008
  • This paper presents 6bit 100MHz Interpolation Flash Analog-to-Digital Converter, which can be applied to the Receiver of Wireless Tele-communication System. The 6bit 100MHz Flash Analog-to-Digital Converter simplifies and integrates S-R latch which multiplies as the resolution increases. Whereas the conventional NAND based S-R latch needed eight MOS transistors, this Converter was designed with only six, which makes the Dynamic Power Dissipation of the A/D Converter reduced up to 12.5%. The designed A/D Converter went through $0.18{\mu}m$ CMOS n-well 1-poly 6-metal process to be a final product, and the final product has shown 282mW of power dissipation with 1.8V of Supply Voltage, 100MHz of conversion rate. And 35.027dBc, 31.253dB SFDR and 4.8bits, 4.2bits ENOB with 12.5MHz, 50MHz of each input frequency.

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

Implementation of Successive Approximate Register typed A/D Converter for a Monitored Battery Voltage Conversion (모니터링된 배터리 전압 변환을 위한 SAR typed A/D 컨버터의 제작)

  • Kim, Seong-Kweon;Lee, Kyung-Ryang;Yeo, Sung-Dae;Hong, Justin S.Y.;Park, Yong-Eun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.256-261
    • /
    • 2011
  • In this paper, a design and an implementation of an Analog to Digital (A/D) converter are introduced for the conversion of monitored battery cell voltage in the cell voltage monitoring(CVM) system in battery management system(BMS), which is one of the key devices of ECO hybrid cars. The A/D converter in CVM system required a middle conversion speed and a high resolution, therefore, a successive approximate register(SAR) typed A/D converter with 10 bits resolution has been designed and implemented using Magna 0.6um 40V process. The measurement result which kept ${\pm}1$ LSB accuracy in the full scale range(FSR) of 5V, showed the usefulness of the SAR typed A/D converter in realizing a CVM system.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Implementation of 24bit Sigma-delta D/A Converter for an Audio (오디오용 24bit 시그마-델타 D/A 컨버터 구현)

  • Heo, Jeong-Hwa;Park, Sang-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.53-58
    • /
    • 2008
  • This paper designs sigma-delta D/A Converter with a high resolution and low power consumption. It reorganizes the input data along LJ, RJ, I2S mode and bit mode to the output data of A/D converter. The D/A converter decodes the original analog signal through HBF, Hold and 5th CIFB(Cascaded Integrators with distributed Feedback as well as distributed input coupling) sigma-delta modulation blocks. It uses repeatedly the addition operation in instead of the multiply operation for the chip area and the performance. Also, the half band filters of similar architecture composed the one block and it used the sample-hold block instead of the sinc filter. We supposed simple D/A Converter decreased in area. The filters of the block analyzed using the matlab tool. The top block designed using the top-down method by verilog language. The designed block is fabricated using Samsung 0.35um CMOS standard cell library. The chip area is 1500*1500um.

  • PDF

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF