• 제목/요약/키워드: ADC12

검색결과 145건 처리시간 0.024초

위치 기반 시스템을 위한 CMOS IR-UWB RFIC (A CMOS IR-UWB RFIC for Location Based Systems)

  • 이중무;박명철;어윤성
    • 전자공학회논문지
    • /
    • 제52권12호
    • /
    • pp.67-73
    • /
    • 2015
  • 본 논문에서는 근거리 위치 기반 시스템을 위한 3 - 5 GHz IR-UWB(impulse radio-ultra wide band) RFIC를 제안한다. 수신기의 구조는 에너지 검출 방식으로 설계되었고, 고속 sampling을 하기 위해서 4 bit ADC 와 DLL(delay locked loop) 을 이용하여 equivalent-time sampling 기술을 사용하도록 설계되었다. 송신기는 저전력의 디지털 UWB impulse generator 를 설계하였다. 설계된 IR-UWB RFIC 는 CMOS $0.18{\mu}m$ 공정을 이용하여 제작되었다. 측정된 수신기의 감도는 -85.7 dBm 이며, 송신기와 수신기는 1.8 V 전원 전압에서 각각 32 mA 와 25.5 mA 의 전류를 소모한다.

전자기력을 이용한 알루미늄 합금중 개재물의 연속적 제거에 관한 연구 (A study on the Continuous Elimination of Inclusions in Al Alloy by Electromagnetic Force)

  • 윤의박
    • 한국주조공학회지
    • /
    • 제22권3호
    • /
    • pp.130-136
    • /
    • 2002
  • The growing use of aluminum for castings over the past decade has brought with it the increased scrutiny of component properties. One area that has received much attention is the effect of in inclusions - or impurities particles held in the metal - on casting properties. A new method of electromagnetic separation for removal of inclusions in aluminum alloy melts is proposed. The principle is that as the electromagnetic force induced in metal acts on inclusions due to low electric conductivity, they are moved to the direction opposite to electromagnetic force and can be separated and removed from the melt. Experiments were carried out on A356 melt mixed alumina particles and commercial Al alloys of ADC 10 and 12. In the experiment using A356, it was proved that $Al_2O_3$ particles was separated and removed continuously from matrix melt by electromagnetic force. Based on these results, the continuous separation experiment that used ADC 10, 12 was carried and the cleanliness of melt was assessed by the amount of porosity, hydrogen contents, PoDFA and mechanical properties through tensile test. As the results of analyses, the amount of porosity and hydrogen contents decreased without variation of chemical composition in the specimen that passed the electromagnetic continuous separator. In addition, tensile strength and elongation of this specimen increased by $20{\sim}30%$ because of reduction of inclusions.

Development and Validation of a Model Using Radiomics Features from an Apparent Diffusion Coefficient Map to Diagnose Local Tumor Recurrence in Patients Treated for Head and Neck Squamous Cell Carcinoma

  • Minjae Kim;Jeong Hyun Lee;Leehi Joo;Boryeong Jeong;Seonok Kim;Sungwon Ham;Jihye Yun;NamKug Kim;Sae Rom Chung;Young Jun Choi;Jung Hwan Baek;Ji Ye Lee;Ji-hoon Kim
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1078-1088
    • /
    • 2022
  • Objective: To develop and validate a model using radiomics features from apparent diffusion coefficient (ADC) map to diagnose local tumor recurrence in head and neck squamous cell carcinoma (HNSCC). Materials and Methods: This retrospective study included 285 patients (mean age ± standard deviation, 62 ± 12 years; 220 male, 77.2%), including 215 for training (n = 161) and internal validation (n = 54) and 70 others for external validation, with newly developed contrast-enhancing lesions at the primary cancer site on the surveillance MRI following definitive treatment of HNSCC between January 2014 and October 2019. Of the 215 and 70 patients, 127 and 34, respectively, had local tumor recurrence. Radiomics models using radiomics scores were created separately for T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE-T1WI), and ADC maps using non-zero coefficients from the least absolute shrinkage and selection operator in the training set. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of each radiomics score and known clinical parameter (age, sex, and clinical stage) in the internal and external validation sets. Results: Five radiomics features from T2WI, six from CE-T1WI, and nine from ADC maps were selected and used to develop the respective radiomics models. The area under ROC curve (AUROC) of ADC radiomics score was 0.76 (95% confidence interval [CI], 0.62-0.89) and 0.77 (95% CI, 0.65-0.88) in the internal and external validation sets, respectively. These were significantly higher than the AUROC values of T2WI (0.53 [95% CI, 0.40-0.67], p = 0.006), CE-T1WI (0.53 [95% CI, 0.40-0.67], p = 0.012), and clinical parameters (0.53 [95% CI, 0.39-0.67], p = 0.021) in the external validation set. Conclusion: The radiomics model using ADC maps exhibited higher diagnostic performance than those of the radiomics models using T2WI or CE-T1WI and clinical parameters in the diagnosis of local tumor recurrence in HNSCC following definitive treatment.

초음파를 이용한 비상방송시스템에 관한 연구 (Study on the Emergency Broadcasting System Using Ultrasonic Waves)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.186-189
    • /
    • 2019
  • NFSC202에는 화재로 인하여 하나의 층의 확성기 또는 배선이 단락되어도 다른 층의 화재 통보에 지장이 없도록 규정하고 있다. 이를 위해 Analog digital converter (ADC), High pass filter (HPF), Low pass filter (LPF)로 구성된 초음파송수신장치를 제작하였으며 시험을 통해 해당 장치가 증폭기출력, 확성기용량, 음량레벨의 변동에 관계없이 동작함을 확인하였다. 또한 기준주파수 110 kHz(-12 dB)를 송신하는 경우 단락시 -12dB~-18 dB, 정상인 경우-24 dB~-66 dB, 단선시에는 -66 dB을 초과하는 경우와 수신데이터가 없는 경우의 설정된 값을 만족하였다. 따라서 NFSC202 규정에 적정한 시스템임을 확인하였으며 본 시스템을 적용할 경우 점검기준이나 시험기준이 수정 또는 개정되어야 한다.

W-CDMA 기지국용 디지털 수신기의 CIC 롤 오프 보상필터 설계 (Design of Cic roll-off Compensation Filter in Digital Receiver For W-CDMA NODE-B)

  • 김성도;최승원
    • 대한전자공학회논문지TC
    • /
    • 제40권12호
    • /
    • pp.155-160
    • /
    • 2003
  • ADC (Analog-to-Digital Converter) 와 DSP (Digital Signal Processor) 의 성능이 향상됨에 따라 아날로그 방식으로 처리하던 IF(Intermidiate Frequency) 대역의 신호를 디지털 방식으로 처리할 수 있게 되었다. 이를 디지털 라디오 또는 디지털 IF라 하고 이는 SDR (software definied radio) 의 초기단계라 할 수 있다. 디지털 라디오 개념을 수신단에 적용할 경우 오버샘플링에 의한 처리 이득을 얻을 수 있으며, 다중 캐리어방식의 수신단 설계가 가능하다. 디지털 수신기에서는 연산량 이득을 위해 데시메이션이 이루어지며, CIC (Cascaded Integrated Comb) 및 halfbandHalfband 필터 등이 앨리어싱방지 필터로 사용된다. 그런데, CIC 필터는 필연적으로 통과대역 내에서 롤 오프 현상이 발생하며, 이것은 수신단 필터의 통과대역 평탄도를 악화시켜서 수신성능의 저하를 초래한다. FIR 필터를 이용하여 보상해 주어야 한다. 본 논문에서는 W-CDMA 디지털 수신기의 수신성능에 최적인 CIC 롤오프 보상 필터를 설계방법을 제시하고, 설계된 필터가 CIC필터의 롤오프 특성을 보상하여 BER(Bit Error Rate)을 최소화시킴을 컴퓨터 시뮬레이션을 통해 확인하였다. 필터 성능을 검증하였다.

Monitoring Response to Neoadjuvant Chemotherapy of Primary Osteosarcoma Using Diffusion Kurtosis Magnetic Resonance Imaging: Initial Findings

  • Chenglei Liu;Yan Xi;Mei Li;Qiong Jiao;Huizhen Zhang;Qingcheng Yang;Weiwu Yao
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.801-811
    • /
    • 2019
  • Objective: To determine whether diffusion kurtosis imaging (DKI) is effective in monitoring tumor response to neoadjuvant chemotherapy in patients with osteosarcoma. Materials and Methods: Twenty-nine osteosarcoma patients (20 men and 9 women; mean age, 17.6 ± 7.8 years) who had undergone magnetic resonance imaging (MRI) and DKI before and after neoadjuvant chemotherapy were included. Tumor volume, apparent diffusion coefficient (ADC), mean diffusivity (MD), mean kurtosis (MK), and change ratio (ΔX) between pre-and post-treatment were calculated. Based on histologic response, the patients were divided into those with good response (≥ 90% necrosis, n = 12) and those with poor response (< 90% necrosis, n = 17). Several MRI parameters between the groups were compared using Student's t test. The correlation between image indexes and tumor necrosis was determined using Pearson's correlation, and diagnostic performance was compared using receiver operating characteristic curves. Results: In good responders, MDpost, ADCpost, and MKpost values were significantly higher than in poor responders (p < 0.001, p < 0.001, and p = 0.042, respectively). The ΔMD and ΔADC were also significantly higher in good responders than in poor responders (p < 0.001 and p = 0.01, respectively). However, no significant difference was observed in ΔMK (p = 0.092). MDpost and ΔMD showed high correlations with tumor necrosis rate (r = 0.669 and r = 0.622, respectively), and MDpost had higher diagnostic performance than ADCpost (p = 0.037) and MKpost (p = 0.011). Similarly, ΔMD also showed higher diagnostic performance than ΔADC (p = 0.033) and ΔMK (p = 0.037). Conclusion: MD is a promising biomarker for monitoring tumor response to preoperative chemotherapy in patients with osteosarcoma.

신호교차로에서의 사고예측모형개발 및 위험수준결정 연구 (Development of a Traffic Accident Prediction Model and Determination of the Risk Level at Signalized Intersection)

  • 홍정열;도철웅
    • 대한교통학회지
    • /
    • 제20권7호
    • /
    • pp.155-166
    • /
    • 2002
  • 교차로에서의 교통사고건수는 90년 이후로 계속 증가해오고 있는 추세이므로 교차로의 안전성을 증가시키기 위한 노력이 필요한 실정이다. 본 연구에서는 신호 교차로의 도로조건, 교통조건 교통운영조건 등을 분석하여 안전성에 방해가 되는 요소들을 찾아내고, 그 요소들과 사고와의 상관관계를 이용하여 각 교차로의 안전을 평가할 수 있는 사고예측모형을 개발하였다. 또한 이 교차로사고예측모형은 사전에 위험요소들을 처리하여 적절한 교통안전 정책을 세우도록 방향을 제시하고, 교차로의 안전성을 높이려는데 목적이 있다. 교차로 내의 사고건수는 2001년 1월부터 2001년 12월까지 1년 간의 원주시 교차로 사고건수 자료를 수집하였고, 각 교차로들의 도로조건, 교통조건, 교통운영조건은 현장 조사하여 수집하였다. 수집한 자료들을 1차 통계 분석한 결과 사고와 상관관계가 높게 나타나는 요소들로는 지역유형, 토지이용, 버스정차활동, 노상 주 정차 활동 전체교통량, 회전 교통량, 차로수, 도로폭, 교차로 면적, 주기, 시거, 회전반경 등으로 나타났다. 또한 위의 요소들을 가지고 2차 상관 분석한 결과 유의확률이 95%이상 만족하고, 각각의 독립변수들 간의 상관관계가 적어 사고율에 영향을 주는 변수로는 차로수, 회전반경, 시거, 주기가 선택되었다. 따라서 위의 요소들로 각 요소들의 분포현황에 알맞은 교통 사고예측 모형 식을 만들고, 일반적인 선형회귀모형과의 정확도를 비교하였다. 또한 국내 사고통계를 이용하여 사고건수의 분포도를 분석한 후 교차로의 위험 수준을 단계별로 분류하였다. 마지막으로 모형의 타당성을 검토하기 위해 Spearman 순위상관계수에 적용하였더니 결정계수 값이 0.985로 매우 유의 하다는 것과 모형식에서 구해진 각 교차로별 위험 순위도가 거의 타당한 것으로 나타났다. 또한 실제사고건 수와 예측사고건수를 본 연구에서 분류한 위험수준으로 비교한 결과 교차로의 80%가 위험수준이 같다는 결과를 얻을 수 있었다.다는 일반적인 명령과 개별적인 행정행위를 구분하고 명령에 대하여도 취소소송의 대상으로 삼도록 하는 보다 명확하고 일관성 있는 논의전개를 제안하였다.수 있었다.로 첨가하여 48시간 배양한 후 암항원 유전자 발현성을 측정한 결과 세포주에 따라 다소 차이는 있으나 대개 0.2 uM농도에서도 유전자 발현이 유도되었으며 1, 5 uM농도에서 매우 강하게 유도되었다. ADC 처리가 페암세포주의 MHC와 B7 발현을 증가시키는가를 알아보기 위해 1 uM 농도의 ADC를 72시간 처치한 후 FACS 분석을 실시한 결과 4개의 페암세포주에서 MHC 및 B7분자의 발현은 유도되지 않았다. 또 ADC농도가 세포성장에 미치는 영향을 알아보기 위하여 ADC를 0.2, 1, 5 uM농도로 96시간 처치 후 세포수를 측정하여 상대성장지수를 알아본 결과 ADC 처치 농도가 증가함에 따라 세포의 성장은 매우 감소하였다. 결론: 폐암세포주에서 ADC처치는 MAGE, GAGE 및 NY-ESO-1과 같은 세포독성 T 림프구 반응을 유도할 수 있는 암항원의 발현을 증가시킬 수 있으며, ADC의 세포독성과 항원 발현 유발시간을 분석할 때 1 uM 농도에서 48시간 처치한 후 ADC가 없는 배지에서 수일간 배양하는 것이 가장 효과적이라고 생각된다. 그러나, ADC를 처치하여도 MHC 및 B7의 발현의 변화는 없었으므로 ADC를 처치한 폐암세포를 암백신으로 사용하기 위해서는 MHC나 B7 및 cytokine의 발현을 증가시키는 추가적인 처치가 필요하다고 생각된다.ded.한 질소제거를 N-balance로부터 구해보면, R3 반응조의 경우가 가장 높은 제거율(40.9%)을 보였다. 이상의 결과들을 볼 때, Bncillus 균주는 호기적 탈질을 일으킬 수 있는 가능성이 있고, Bncillus 균주를 이용한 B3 공정은 탈질에 이용되는 탄소량이 거의 없고, 적은 alkalinity 소모에 의한 경제적 이익 등 장점을 가진 공정으로 보여 진다.수록 푹신한

유량측정 기기별 측정성과에 대한 실험적 비교분석 (Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters)

  • 이재혁;이석호;정성원;김태웅
    • 한국습지학회지
    • /
    • 제12권1호
    • /
    • pp.95-103
    • /
    • 2010
  • 유량자료는 물의 순환과정을 규명하고 효율적인 수자원 개발 및 이수 치수 계획 등에 매우 귀중하게 이용된다. 그러나 이러한 유량자료를 확보하는데 많은 시간과 경비 등이 요구되기 때문에 주요 수위에서 유량자료는 수위-유량관계곡선식(Stage-Discharge Curve)을 개발하여 유량을 산정하고 있다. 따라서 수위-유량관계곡선식의 신뢰도는 유량자료의 품질에 절대적인 영향을 미치는 요인으로 작용된다. 수문학을 전공하고 연구하는 많은 학자들은 고품질의 유량자료를 생산하여 신뢰성 있는 곡선식을 개발하고자 유량측정 방법과 기준, 장비개발 및 개량 등에 관한 연구를 수행하고 있다. 현재 국내에서는 다양한 유량측정기기를 사용하여 유량자료를 생산하고 활용하고 있으나, 측정기기별 정확도 및 실험적 측정성과에 대한 연구자료가 미흡한 실정이다. 본 연구에서는 규격화된 콘크리트 수로에 일정한 유량을 흘려보내는 조건에서 다양한 측정기기를 이용하여 유속을 측정하였다. 그리고 이 측정성과를 이용하여 유량을 산정하고 비교분석하였다. 실험을 위해서 국내에서 일반적으로 사용되고 있는 측정기기로 프라이스 유속계(USGS Type AA Current Meter), 휴대용 유량계(Flow Meter), 초음파식 디지털 유속계(ADC), C2 유속계(C2 Small Current Meter), 플로우 트렉커(Flow Tracker), 마그네틱 유속계(Electromagnetic Current Meter) 등의 장비를 사용하여 유량을 산정하였으며, 각 기기별 산정된 유량을 비교 분석 하였다. 비교검토에 적용하고자 측정한 수심으로는 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m의 왕복측정 6-Case로 진행이 되었으며, 신뢰성과 정확도를 높이기 위해 도섭법으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter는 유속측정기기의 검교정을 받았으므로 다른 실험유량측정치의 비교를 위한 기준값으로 사용하였다. 따라서 국내에서 널리 사용되는 측정기기(USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter, Flow Tracker, Electromagnetic Current meter)별 검토 결과 평균유량 및 평균유속에 있어 프라이스 유속계를 기준으로 마그네틱 유속계 $\pm$ 10 % 이상, 플로우 트렉커 $\pm$ 10 % 미만, 휴대용 유량계, 초음파식 디지털 유속계 및 C2 유속계는 $\pm$ 5 % 미만의 차이가 있음을 확인할 수 있었다.

저전력 12비트 1MSps 연속 근사형 레지스터 아날로그-디지털 변환기 설계 (Design of a Low-Power 12-bit 1MSps SAR ADC)

  • 최성규;김철환;성명우;김신곤;임재환;최근호;;류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.156-157
    • /
    • 2014
  • 본 논문에서는 저전력 12비트 1MSps 연속 근사형 레지스터 아날로그-디지털 변환기를 제안한다. 제안하는 회로는 1.8V의 공급 전압에서 동작하며, Magnachip/SK Hynix $0.18{\mu}m$ CMOS 1Poly-6Metal 공정을 이용하여 설계하였다. 입력신호의 주파수가 100kHz일 때, 설계된 회로는 3.24mW의 낮은 소비전력 특성, $0.56mm^2$의 작은 칩 면적 특성, 70.03dB의 SNDR(Signal-to-Noise Distortion Ratio) 및 11.34비트의 ENOB(Effective Number of Bits) 특성을 보였다.

  • PDF

정진폭 다중 부호 이진 직교 변복조기의 FPGA 설계 및 SoC 구현 (FPGA Design and SoC Implementation of Constant-Amplitude Multicode Bi-Orthogonal Modulation)

  • 홍대기;김용성;김선희;조진웅;강성진
    • 한국통신학회논문지
    • /
    • 제32권11C호
    • /
    • pp.1102-1110
    • /
    • 2007
  • 본 논문에서는 기존의 정진폭 다중 부호 이진 직교 (CAMB: Constant-Amplitude Multi-code Biorthogonal) 변조 이론을 적용한 변복조기를 프로그래밍 가능한 게이트 배열 (FPGA: Field-Programmable Gate Array)을 사용하여 설계하고 시스템 온 칩 (SoC: System on Chip)으로 구현하였다. 이 변복조기는 FPGA을 이용하여 타겟팅 한 후 보드실험을 통해 설계에 대한 충분한 검증을 거쳐 주문형 반도체 (ASIC: Application Specific Integrated Circuit) 칩으로 제작되었다. 이러한 12Mbps급 모뎀의 SoC를 위하여 ARM (Advanced RISC Machine)7TDMI를 사용하였으며 64K바이트 정적 램 (SRAM: Static Random Access Memory)을 내장하였다. 16-비트 PCMCIA (Personal Computer Memory Card International Association), USB (Universal Serial Bus) 1.1, 16C550 Compatible UART (Universal Asynchronous Receiver/Transmitter) 등 다양한 통신 인터페이스를 지원할 뿐 아니라 ADC (Analog to Digital Converter)/DAC (Digital to Analog Converter)를 포함하고 있어 실제 현장에서 쉽게 활용될 수 있을 것으로 기대된다.