• Title/Summary/Keyword: ADC

Search Result 817, Processing Time 0.031 seconds

Analysis of Quantization Noise in Magnetic Resonance Imaging Systems (자기공명영상 시스템의 양자화잡음 분석)

  • Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 2004
  • Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.

  • PDF

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Diffusion-weighted MR Imaging of Hypoxic-Ischemic Encephalopathy (저산소성-허혈성 뇌증의 확산강조영상 소견)

  • Choi, Hye-Young;Choi, Dae-Seob;Ryoo, Jae-Wook;Cho, Jae-Min;Ko, Eun-Sook;Shin, Tae-Beom;Na, Jae-Beom;Choi, Nak-Cheon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.49-54
    • /
    • 2008
  • Purpose : The purpose of this study was to determine the characteristics of hypoxic-ischemic encephalopathy (HIE) on diffusion-weighted imaging (DWI) and the role of DWI for the diagnosis of HIE. Materials and Methods : Six patients with HIE underwent MRI including DWI. MR examinations were performed within 4 - 32 days (mean, 11.8 days) after hypoxic brain insult. We assessed the distribution of the lesions and compared the DWI and T2, FLAIR images for the subjective conspicuity of the lesions. Results : In all patients, symmetrical hyperintense lesions were demonstrated in the bilateral basal ganglia on T2, FLAIR, and DWI. On ADC map image, the lesions were hypointense in four of six patients and isointense in other two patients. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in four of six patients and similar in other two patients. For the involvement of the cortex and subcortical white matter, in five of six patients, bilateral symmetric hyperintense lesions were seen on T2, FLAIR, and DWI. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in three of them and similar in other two patients. On ADC map image, the lesions showed hypointensity in three of five patients and isointensity in other two patients. For the involvement of the deep cerebral white matter, T2, FLAIR, and DWI showed bilateral symmetric hyperintense lesions in four of six patients. Among them, Lesion conspicuity on DWI was higher than on T2 and FLAIR images in only one patient. Conclusion : HIE is characterized by symmetrical hyperintense lesions in the bilateral basal ganglia, cerebral cortex, and white matter on DWI and the lesions are more conspicuously demonstrated on DWI than on T2 and FLAIR images.

  • PDF

Development of Digital Transceiver Unit for 5G Optical Repeater (5G 광중계기 구동을 위한 디지털 송수신 유닛 설계)

  • Min, Kyoung-Ok;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.156-167
    • /
    • 2021
  • In this paper, we propose a digital transceiver unit design for in-building of 5G optical repeaters that extends the coverage of 5G mobile communication network services and connects to a stable wireless network in a building. The digital transceiver unit for driving the proposed 5G optical repeater is composed of 4 blocks: a signal processing unit, an RF transceiver unit, an optical input/output unit, and a clock generation unit. The signal processing unit plays an important role, such as a combination of a basic operation of the CPRI interface, a 4-channel antenna signal, and response to external control commands. It also transmits and receives high-quality IQ data through the JESD204B interface. CFR and DPD blocks operate to protect the power amplifier. The RF transmitter/receiver converts the RF signal received from the antenna to AD, is transmitted to the signal processing unit through the JESD204B interface, and DA converts the digital signal transmitted from the signal processing unit to the JESD204B interface and transmits the RF signal to the antenna. The optical input/output unit converts an electric signal into an optical signal and transmits it, and converts the optical signal into an electric signal and receives it. The clock generator suppresses jitter of the synchronous clock supplied from the CPRI interface of the optical input/output unit, and supplies a stable synchronous clock to the signal processing unit and the RF transceiver. Before CPRI connection, a local clock is supplied to operate in a CPRI connection ready state. XCZU9CG-2FFVC900I of Xilinx's MPSoC series was used to evaluate the accuracy of the digital transceiver unit for driving the 5G optical repeater proposed in this paper, and Vivado 2018.3 was used as the design tool. The 5G optical repeater digital transceiver unit proposed in this paper converts the 5G RF signal input to the ADC into digital and transmits it to the JIG through CPRI and outputs the downlink data signal received from the JIG through the CPRI to the DAC. And evaluated the performance. The experimental results showed that flatness, Return Loss, Channel Power, ACLR, EVM, Frequency Error, etc. exceeded the target set value.

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

Prognostic Impact of Elevation of Vascular Endothelial Growth Factor Family Expression in Patients with Non-small Cell lung Cancer: an Updated Meta-analysis

  • Zheng, Chun-Long;Qiu, Chen;Shen, Mei-Xiao;Qu, Xiao;Zhang, Tie-Hong;Zhang, Ji-Hong;Du, Jia-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1881-1895
    • /
    • 2015
  • Background: The vascular endothelial growth factor family has been implicated in tumorigenesis and metastasis. The prognostic value of each vascular endothelial growth factor family member, particular VEGF/VEGFR co-expression, in patients with non-small lung cancer remains controversial. Materials and Methods: Relevant literature was identified by searching PubMed, EMBASE and Web of Science. Studies evaluating expression of VEGFs and/or VEGFRs by immunohistochemistry or ELISA in lung cancer tissue were eligible for inclusion. Hazard ratios (HRs) and 95% confidence intervals (CIs) from individual study were pooled by using a fixed- or random-effect model, heterogeneity and publication bias analyses were also performed. Results: 74 studies covering 7,631 patients were included in the meta-analysis. Regarding pro-angiogenesis factors, the expression of VEGFA (HR=1.633, 95%CI: 1.490-1.791) and VEGFR1 (HR=1.924, 95%CI: 1.220-3.034) was associated separately with poor survival. Especially, VEGFA over-expression was an independent prognostic factor in adenocarcinoma (ADC) (HR=1.775, 95%CI: 1.384-2.275) and SCC (HR=2.919, 95%CI: 2.060-4.137). Co-expression of VEGFA/VEGFR2 (HR=2.011, 95%CI: 1.405-2.876) was also significantly associated with worse survival. For lymphangiogenesis factors, the expression of VEGFC (HR=1.611, 95%CI: 1.407-1.844) predicted a poor prognosis. Co-expression of VEGFC/VEGFR3 (HR=2.436, 95%CI: 1.468-4.043) emerged as a preferable prognostic marker. Conclusions: The expression of VEGFA (particularly in SCC and early stage NSCLC), VEGFC, VEGFR1 indicates separately an unfavorable prognosis in patients with NSCLC. Co-expression VEGFA/VEGFR2 is comparable with VEGFC/VEGFR3, both featuring sufficient discrimination value as preferable as prognostic biologic markers.

K-Ras-Activated Cells Can Develop into Lung Tumors When Runx3-Mediated Tumor Suppressor Pathways Are Abrogated

  • Lee, You-Soub;Lee, Ja-Yeol;Song, Soo-Hyun;Kim, Da-Mi;Lee, Jung-Won;Chi, Xin-Zi;Ito, Yoshiaki;Bae, Suk-Chul
    • Molecules and Cells
    • /
    • v.43 no.10
    • /
    • pp.889-897
    • /
    • 2020
  • K-RAS is frequently mutated in human lung adenocarcinomas (ADCs), and the p53 pathway plays a central role in cellular defense against oncogenic K-RAS mutation. However, in mouse lung cancer models, oncogenic K-Ras mutation alone can induce ADCs without p53 mutation, and loss of p53 does not have a significant impact on early K-Ras-induced lung tumorigenesis. These results raise the question of how K-Ras-activated cells evade oncogene surveillance mechanisms and develop into lung ADCs. RUNX3 plays a key role at the restriction (R)-point, which governs multiple tumor suppressor pathways including the p14ARF-p53 pathway. In this study, we found that K-Ras activation in a very limited number of cells, alone or in combination with p53 inactivation, failed to induce any pathologic lesions for up to 1 year. By contrast, when Runx3 was inactivated and K-Ras was activated by the same targeting method, lung ADCs and other tumors were rapidly induced. In a urethane-induced mouse lung tumor model that recapitulates the features of K-RAS-driven human lung tumors, Runx3 was inactivated in both adenomas (ADs) and ADCs, whereas K-Ras was activated only in ADCs. Together, these results demonstrate that the R-point-associated oncogene surveillance mechanism is abrogated by Runx3 inactivation in AD cells and these cells cannot defend against K-Ras activation, resulting in the transition from AD to ADC. Therefore, K-Ras-activated lung epithelial cells do not evade oncogene surveillance mechanisms; instead, they are selected if they occur in AD cells in which Runx3 has been inactivated.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Design of RF Front-end for High Precision GNSS Receiver (고정밀 위성항법 수신기용 RF 수신단 설계)

  • Chang, Dong-Pil;Yom, In-Bok;Lee, Sang-Uk
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.64-68
    • /
    • 2007
  • This paper describes the development of RF front.end equipment of a wide band high precision satellite navigation receiver to be able to receive the currently available GPS navigation signal and the GALILEO navigation signal to be developed in Europe in the near future. The wide band satellite navigation receiver with high precision performance is composed of L - band antenna, RF/IF converters for multi - band navigation signals, and high performance baseband processor. The L - band satellite navigation antenna is able to be received the signals in the range from 1.1 GHz to 1.6 GHz and from the navigation satellite positioned near the horizon. The navigation signal of GALILEO navigation satellite consists of L1, E5, and E6 band with signal bandwidth more than 20 MHz which is wider than GPS signal. Due to the wide band navigation signal, the IF frequency and signal processing speed should be increased. The RF/IF converter has been designed with the single stage downconversion structure, and the IF frequency of 140 MHz has been derived from considering the maximum signal bandwidth and the sampling frequency of 112 MHz to be used in ADC circuit. The final output of RF/IF converter is a digital IF signal which is generated from signal processing of the AD converter from the IF signal. The developed RF front - end has the C/N0 performance over 40dB - Hz for the - 130dBm input signal power and includes the automatic gain control circuits to provide the dynamic range over 40dB.

  • PDF

Soil Problems and Agricultural Water Management of the Reclaimed Land in Korea (한국의 간척지에서 토양 문제와 농업 용수 관리)

  • Jung, Yeong-Sang;Yoo, Chul-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.4
    • /
    • pp.330-348
    • /
    • 2007
  • Soil problems and agricultural water management of the reclaimed land in Korea were reviewed through research results conducted in RDA and ADC. According to the Korean Soil Classification and Soil Survey(NIAST, 2002), the 5 soil orders with the 45 soil series were distributed on the fluvio-marine or marine deposit of the west and south coastal plains. Yeompo, Munpo, Hasa, Gwangwhal, and Poseung soil series were most commonly distributed soil on the fluvio-marine deposits, associated with tideland of the sea coast. Former 4 soils were Entisols, and the latest one was the Inceptisols. Buyong soil associated with Poseung series was an Alfisols. Extent of Myeongji soil, a Molisols, and Yongho soil, a Histosol, were minor. Salinity control and management problems were closely related with high water table and low percolation rate due to plow-pan layer developed during the leaching process in the silty textured soil. For evaluation of field salinity, use of an electromagnetic inductance, EM38, with GPS was helpful to understand salinity status and field variability. Deep plowing, subsoiling and drainage improvement by tile drainage might be effective in paddy with plow-pan. New technology such as variable rate fertilization might save fertilizers and thus reduce environmental impact of agriculture on water quality. Water quality of agricultural water resources in reclaimed land was less adequate than that of inland water resources. Proper crop management is necessary depended upon quality for crop growth as well as to match with water quality target.