• Title/Summary/Keyword: ACL

Search Result 460, Processing Time 0.024 seconds

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF

Relationship between Graft Appearance on Follow-up MRI and Knee Stability after Double Bundle ACL Reconstruction (이중 다발 전방십자 재건술 후 이식건의 자기공명영상 추시와 슬관절 안정성과의 관계)

  • Sim, Jae Ang;Kwak, Ji Hoon;Lee, Yong Seuk;Kim, Kwang Hui;Nam, Shin Woo;Jun, Sung Soo;Lee, Beom Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.128-133
    • /
    • 2012
  • Purpose: This study examined the relationship between graft appearance on follow-up magnetic resonance imaging (MRI) and knee stability after double bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: For each patient, 1.5 tesla MRI's were obtained. The signal intensity of grafts was divided into 3 grades by Sononda's classification. The course of grafts was divided into two patterns: straight and curved. We assessed Lachman test, KT 2000 arthrometer and anterior drawer stress radiograph using Telos$^{(R)}$ in $30^{\circ}$ knee flexion for anterior stability and evaluated pivot shift test for rotatory stability. The correlation between graft appearance on MRI and the results of knee stability tests was evaluated. Results: The anteromedial (AM) graft was evaluated as being grade 1 in 66.7%, grade 2 in 26.7%, and grade 3 in 6.7% of the cases and the posterolateal (PL) graft was assessed as being grade 1 in 63.3%, grade 2 in 33.3%, and grade 3 in 3.3% of the cases according to the signal intensity. The AM graft was evaluated as being straight in 83.3% and curved in 16.7% of the cases, and the PL graft was assessed as being straight in 86.7% and curved in 13.3% of the cases according to the course. The course of AM graft was correlated with the results of anterior stability tests and the course of PL graft was correlated with the result of rotatory stability test. However, the signal intensity of grafts was not correlated with the results of anterior stability and rotatory stability tests. Conclusion: The course of AM is correlated with anterior stability and the course of PL is correlated with rotatory stability on follow-up MRI after double bundle ACL reconstruction.

  • PDF

Clinical Results of ACL Reconstruction in the Immature Adolescent via Transphyseal Approach in Tibia Based on a New Indication Paradigm (새로운 수술적응증에 의한 골 미성숙 전방십자인대 손상 환자에서의 성장판을 통과하는 전방십자인대 재건술의 결과)

  • Lee, Dong Chul;Shon, Oog Jin;Park, Chul-Hyun;Kwon, Moon Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: To evaluate clinical and radiologic outcomes of transphyseal anterior cruciate ligament (ACL) reconstruction in patients with open physes who were selected with authors' new operative indications. Materials and Methods: We evaluated 15 patients with open physes who underwent a transtibial ACL reconstruction and were followed up for 4~6 years after surgery. Our operative indications involved 1) choronologic age of ${\geq}$ 16 in male and ${\geq}$ 14 in female, 2) open physes of ${\leq}$ 2 mm width, and 3) Risser sign and Tanner stage of ${\geq}$ 3. Tibialis anterior tendon allograft was used in all patients, and endobutton and bioscrew were used for femoral and tibial fixations, respectively. Functional outcomes were evaluated using Lysholm Knee Scoring scale, Tegner activity scale, and International Knee Documentation Committee (IKDC) 2000 subjective score. Physical examinations to evaluate stability involved Lachman and pivot shift tests. For radiographic results, we evaluated side to side differences of anterior displacement in stress views. In addition, with use of scannograms taken at last follow-up, we examined side to side differences of femorotibial angles, anatomical and mechanical lateral distal femoral angles, mechanical medial proximal tibial angles and leg lengths. Results: The mean Lysholm Knee score was 51(40-61) points preoperatively and 97(94-100) points at last follow up. The mean Tegner activity score was 2.6 points preoperatively and 7.1 points at last follow up. The mean IKDC score was 32.6 points preoperatively and 88.3 points at last follow up. The mean anterior displacement of the tibia was improved from 6.7(${\pm}1.0$) mm to 1.9(${\pm}0.9$) mm. There were no leg length discrepancies over 5 mm and no statistically significant differences in all the radiographic variables representing growth disturbance. Conclusion: This study suggests that patients with open physes who selected by authors' new indication would safely undergo transphyseal ACL reconstruction with successful outcomes.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교)

  • Sohn, Sung-Keun;Chang, Yun-Suk;Chung, ll-Kwon;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • Purpose: Recent development and advances in arthroscopic surgical techniques for Anterior Cruciate Ligament(ACL) reconstruction have led to the ideal location for the etric point from 10 o'clock (in right knee) and 13:30 (in left knee) to 10:30 (in right knee) and 14 o'clock (in left knee) in the frontal plane. This study was performed to compare operative methods and the radiologic results of femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Material and Methods: From January 2003 to May 2004, one-hundred reconstructions of anterior cruciate ligament were performed. Group I (femoral tunnel through tibial tunnel) was composed of 50 cases and group ll (femoral tunnel through anteromedial portal) was consisted of 50 cases. The study was performed to compare the radiographic results of femoral tunnels made through the tibial tunnel and the anteromedial portal and operative methods. Results: In operative methods at Group II, femoral tunnel was made more easily at isometric point than Group I, a good visual field was achived because 100$^{\circ}$ flxion of knee, they can be reduced risk of posterior cortical breakage and tunnel-graft mismatching and decreased divergence of femoral interference screw in radiology (P<0.05). The angle between femoral tunnel and longitudinal axis of ACL wae increased at Group ll. Conclusion: Aanteromedial portal technique was more useful in ACL reconstruction for femoral tunnel toward 10 o'clock to10:30(in right) or 1:30 to 2 o'clock(in left).

  • PDF

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

Clinical Results of Footprint Restoration Anterior Cruciate Ligament Reconstruction with Remnant Preservation (잔여부 보존술식을 이용한 고유부착부 재현 전방십자인대 재건술의 임상결과)

  • Chung, Hyun-Min;Seo, Young-Jin;Song, Si Young;Cha, Myoungsoo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.537-546
    • /
    • 2019
  • Purpose: Anteromedial (AM), posterolateral (PL), anterior, and posterior remnant preserving anterior cruciate ligament (ACL) reconstructions were conducted on patients with partial ACL tears based on the arthroscopic findings. The clinical results of the four groups were compared. Materials and Methods: This study included 98 patients who underwent a remnant preserving ACL reconstruction from January 2013 to June 2016 and could be followed-up for at least two years. The subjects were categorized into four groups according to the selective bundles reconstructed: group A, anteromedial selective bundle reconstruction; group B, posterolateral selective bundle reconstruction; group C, anterior bundle reconstruction; and group D, posterior bundle reconstruction. The preoperative and postoperative anterior translation from the stress X-ray, International Knee Documentation Committee Subjective Knee Form (IKDC SKF) score, Lysholm score, and hospital for special surgery (HSS) score were compared. Results: All four groups showed significant improvement in anterior translation on the stress X-ray conducted with knees at 15° flexion, IKDC SKF score, Lysholm score, and HSS score postoperatively (in all groups, p<0.001). No intergroup differences were observed in terms of the functional outcomes except that preoperative IKDC SKF score was higher in the C group than in the A group (p=0.021), and the preoperative Lysholm score was higher in the B group than in the A group (p=0.03). Conclusion: After the AM, PL, anterior, and posterior remnant preserving ACL reconstructions, all four groups showed satisfactory results in terms of the anteroposterior stability and functional knee scores with no significant intergroup differences.

A Simulation Model of the ACL Function Using MADYMO (마디모를 이용한 전방십자인대 기능 시뮬레이션 모델)

  • Park, Jung-Hong;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1408-1416
    • /
    • 2006
  • A mathematical knee model was constructed using MADYMO. The purpose of this study is to present a more realistic model of the human knee to reproduce human knee motion. Knee ligaments were modeled as line elements and the surrounding muscles were considered as passive restraint elements. A calf-free-drop test was performed to validate the suggested model. A calf was dropped from the rest at about 65 degree flexed posture in the prone position. The motion data were recorded using four video cameras and then three dimensional data were acquired by Kwon3D motion analysis software. The results showed that general shapes of angular quantities were similar in both the experiment and computer simulation. Functional stability of the anterior cruciate ligament was explicitly revealed through this model.

A Study on the Fixation Characteristics of a Self-expansion Type ACL Fixation Device (자가 확장형 전방십자인대 고정장치의 고정 특성에 대한 연구)

  • Kim, Jong-Dae;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2009
  • This paper studied the influences of the main design parameter-the expansion angle and the material properties of the self-expansion anterior cruciate ligament fixation device on the contact condition with the bone and the initial stability of the device. Using finite element analysis, the stress distributions of the ring part of the device and the wall of the bone tunnel were calculated. And the micro-migration of the device by the pull-out force was calculated. From the analysis results, it was found that when designing the self-expansion type anterior cruciate ligament fixation device, it is desirable to use the material having higher Young's modulus and to design the fixation device that all wedges uniformly maintain contact with bone to obtain initial stability after operation.

  • PDF