• Title/Summary/Keyword: ACI318-08

Search Result 38, Processing Time 0.026 seconds

Effect of the Reinforcement Index on the Unbonded Tendon Stress of Post-tensioned Lightweight Concrete Beams (포스트텐션 경량콘크리트 보의 비부착 긴장재 응력에 대한 보강지수의 영향)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.89-90
    • /
    • 2010
  • Three post-tensioned lightweight concrete beams were tested to examine the effect of the reinforcement index on the unbonded tendon stress at ultimate strength of the beams. The reinforcement index selected for main variables were 0.06, 0.15, 0.30. Test results showed that the stress of the unbonded tendons in the ultimate strength of the post-tensioned lightweight concrete beams can be conservatively evaluated using the empirical equations specified in ACI 318-08.

  • PDF

Evaluation on the Maximum Yield Strength of Steel Stirrups in Reinforced Concrete Beams (철근콘크리트 보에 사용된 전단보강철근의 항복강도 제한에 대한 평가)

  • Lee, Jin-Eun;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.685-693
    • /
    • 2012
  • The yield strength of shear reinforcement is restricted in the present design codes. In this study, the possibility of the yield strength increase in shear reinforcement is evaluated according to ACI318-08, EC2-02 and CSA-04 by comparing the experimental and calculated results. Three cases were used to analyze the shear strength of the beam. One had no limitation in the yield strength of shear reinforcement, another had restriction on the yield strength of shear reinforcement, and the other had a restriction on the yield strength of shear reinforcement and the shear reinforcement ratio. The study results showed that the case with unlimited shear reinforcement yield strength predicted the test result better than other two cases. Even though the rebar yield strength higher than the strength required in present code was applied to existing shear design equation, the result was reasonable. Therefore, the design equation seemed to be appropriate even if the high-strength shear reinforcement is used in practice based on the existing shear design method.

An Experimental Study on Shear Behaviors for Reinforced Concrete Beams Embedded with GFRP Plate with Openings (매립형 유공 GFRP 판으로 보강된 RC보의 전단거동에 관한 실험적 연구)

  • Choi, Jong-Hoon;Kim, Min-Sook;Kim, Hee-Cheul;Lee, Young-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.407-414
    • /
    • 2012
  • The purpose of this study is to experimentally investigate the shear behavior of reinforced concrete beams embedded with GFRP (glass fiber reinforced polymer) plate with openings. In this study, the parameters include the shape of reinforcement, reinforcement area, and thickness and width of reinforcements. The test was performed on 9 specimens with shear spanto-depth ratio of 2.8. When the reinforcement area was varied, the GFRP plate showed 3.6 times greater shear strength than steel stirrup. The test result showed that shear strength increased as reinforcement area increased. Also, when the shape of a parallelogram GFRP plate was used, it showed higher shear strength than that with rectangular shape. Effect of thickness and width of reinforcement showed that shear capacity increased as width increased. For a comparison study, a calculation of the shear strength of reinforced beams with GFRP plate based on the ACI 318M-08 was compared with the test results. The test results were compared with the maximum shear reinforcement areas required by ACI 318M-08, CSA-04, and EC2-02 provision.

Review of Structural Design Provisions of Rectangular Concrete Filled Tubular Columns (각형 콘크리트충전 강관기둥 부재의 구조설계기준 비교연구)

  • Lee, Cheol Ho;Kang, Ki Yong;Kim, Sung Yong;Koo, Cheol Hoe
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • The structural provisions of rectangular CFT (concrete-filled tubular) columns in the 2005/2010 AISC Specification, ACI 318-08, and EC4 were comparatively analyzed as a preliminary study for establishing the unified standards for composite structures. The provisions analyzed included those related to the nominal strength, the effect of confinement, plate slenderness, effective flexural stiffness, and the material strength limitations. Small or large difference can be found among the provisions of AISC, ACI, and EC4. Generally, the 2010 AISC Specification provides the revised provisions which reflect up-to-date test results and tries to minimize the conflict with the ACI provisions. For example, the 2010 AISC Specification introduced a more finely divided plate slenderness limits for CFT columns. In seismic applications, the plate slenderness limits required for highly and moderately ductile CFT columns were separately defined. However, the upper cap limitations on material strengths in both the AISC and EC4 provisions are too restrictive and need to be relaxed considering the high-strength material test database currently available. This study found that no provisions reviewed in this paper provide a generally satisfactory method for predicting the P-M interaction strength of CFT columns under various material combinations. It is also emphasized that a practical constitutive model, which can reasonably reflect the stress-strain characteristics of confined concrete of rectangular CFT columns, is urgently needed for a reliable prediction of the P-M interaction strength.

Evaluation of Seismic Performance of Beam-Column Connections Using Minimally Spaced Headed Reinforcements (근접 배치된 확대머리 철근의 보-기둥 접합부 내진 성능 평가)

  • Cho, Ah Sir;Shin, Hyeong-Yeop;Jeong, Seung Yong;Kang, Thomas H.K.;Kim, Woosuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.1-8
    • /
    • 2019
  • To resolve the conservative requirements for clear headed-bar spacing in KBC 2016 and ACI 318-08, two 2/3-scale exterior beam-column connections were tested under cyclic seismic loading. The seismic tests primarily explored the effect on their seismic performance of using (a) small clear spacings and (b) multiple layers of headed reinforcements in the beam. Also, the previous test data were thoroughly analyzed. It was concluded that the clear bar spacing of 2db or the use of two bar layers might be permitted for headed reinforcements embedded in exterior beam-column connections.

An Experimental Study on Allowable Compressive Stress at Prestress Transfer in Pre-Tensioned Concrete Members (프리텐션된 콘크리트 부재의 프리스트레스 도입시 허용압축응력에 관한 실험적 연구)

  • Lee, Jeong Yeon;Lee, Deuck Hang;Kim, Kang Su;Park, Min Kook;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.9-17
    • /
    • 2012
  • In the previous research, allowable compressive stress was analyzed based on strength theory, in which primary effect factors on the allowable compressive stress, such as eccentricity ratio, section type, section size, prestress and self-weight moment, were considered. As its results, allowable compressive stress equations were proposed. As a series of the previous research, this paper presents an experimental study on the prestress at transfer of pre-tensioned members with different eccentricity ratios. The results shows that ACI318-08 and EC2-02 are unconservative for the members under low eccentricity ratios, and they are conservative for the members under high eccentricity ratios. Compared to the code provisions, the results indicates that the proposed equation reasonably well evaluates the allowable compressive stresses for those with different eccentricity ratios.

Development of a retrofit anchor system for remodeling of building exteriors

  • Yeun, Kyu Won;Hong, Ki Nam;Kim, Jong
    • Structural Engineering and Mechanics
    • /
    • v.44 no.6
    • /
    • pp.839-856
    • /
    • 2012
  • To enable remodeling of the exterior of buildings more convenient, such finishing materials as curtain walls, metal panels, concrete panels or dry stones need to be easily detached. In this respect, this study proposed a new design of the slab for the purposes. In the new design, the sides of the slab were properly modified, and the capabilities of anchors fixed in the modified slab were experimentally tested. In details, a number of concrete specimens with different sizes and compressive strengths were prepared, and the effect of anchors with different diameters and embedment depths applied in the concrete specimens were tested. The test results of the maximum capacities of the anchors were compared with the number of current design codes and the stress distribution was identified. This study found that the embedment depth specified in the current design code (ACI318-08) should be revised to be more than 1.5 times the edge distance. However, with the steel sheet reinforcement, the experiment acquired higher tensile strength than the design code proposed. In addition, for two types of specimens in the tensile strength experiment, the current design code (ACI 318-08) is overestimated for the anchor depth of 75 mm. This study demonstrated that the ideal breakout failure was attainable for the side slot details of a slab with more than 180 mm of a slab thickness and less than 75 mm of an anchor embedment depth. It is expected that these details of the modified slab can be specified in the upgraded construction design codes.

Tests on Cementless Alkali-Activated Slag Concrete Using Lightweight Aggregates

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Lee, Kang-Seok;Song, Jin-Kyu
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Five all-lightweight alkali-activated (AA) slag concrete mixes were tested according to the variation of water content to examine the significance and limitation on the development of cementless structural concrete using lightweight aggregates. The compressive strength development rate and shrinkage strain measured from the concrete specimens were compared with empirical models proposed by ACI 209 and EC 2 for portland cement normal weight concrete. Splitting tensile strength, and moduli of elasticity and rupture were recorded and compared with design equations specified in ACI 318-08 or EC 2, and a database compiled from the present study for ordinary portland cement (OPC) lightweight concrete, wherever possible. Test results showed that the slump loss of lightweight AA slag concrete decreased with the increase of water content. In addition, the compressive strength development and different mechanical properties of lightweight AA slag concrete were comparable with those of OPC lightweight concrete and conservative comparing with predictions obtained from code provisions. Therefore, it can be proposed that the lightweight AA slag concrete is practically applicable as an environmental-friendly structural concrete.

Strength Analysis of Joints in Floating Slab Track (플로팅 슬래브궤도 연결부의 강도 분석)

  • Kwon, Ku-Sung;Chung, Won-Seok;Jang, Seung-Yup
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.375-381
    • /
    • 2011
  • The passage of railway vehicles generates mechanical vibrations and noises. This problem can be mitigated by the 'floating slab track' that isolating from infrastructures by installing vibration isolator in the concrete slab track. In the previous researches, adjacent floating slab tracks are connected by dowel bar system. It has been reported that many dowel bars with less diameter show better load transfer efficiency (LTE) compared to small number of dowel bars with larger diameter under the condition of the same dowel area. In this study, dowel system is further considered as a concrete anchorage system and the design strength of the dowel system was evaluated based on ACI code 318-08 Appendix D. The design strength of dowel system is then verified against failure load test of floating slab system.

  • PDF

Optimum cost design of RC columns using artificial bee colony algorithm

  • Ozturk, Hasan Tahsin;Durmus, Ahmet
    • Structural Engineering and Mechanics
    • /
    • v.45 no.5
    • /
    • pp.643-654
    • /
    • 2013
  • Optimum cost design of columns subjected to axial force and uniaxial bending moment is presented in this paper. In the formulation of the optimum design problem, the height and width of the column, diameter and number of reinforcement bars are treated as design variables. The design constraints are implemented according to ACI 318-08 and studies in the literature. The objective function is taken as the cost of unit length of the column consisting the cost of concrete, steel, and shuttering. The solution of the design problem is obtained using the artificial bee colony algorithm which is one of the recent additions to metaheuristic techniques. The Artificial Bee Colony Algorithm is imitated the foraging behaviors of bee swarms. In application of this algorithm to the constraint problem, Deb's constraint handling method is used. Obtained results showed that the optimum value of numerical example is nearly same with the existing values in the literature.