Browse > Article
http://dx.doi.org/10.4334/JKCI.2012.24.6.685

Evaluation on the Maximum Yield Strength of Steel Stirrups in Reinforced Concrete Beams  

Lee, Jin-Eun (Dept. of Mega Buildings & Bridges, Sungkyunkwan University)
Lee, Jung-Yoon (Dept. of Architectural Engineering, Sungkyunkwan University)
Publication Information
Journal of the Korea Concrete Institute / v.24, no.6, 2012 , pp. 685-693 More about this Journal
Abstract
The yield strength of shear reinforcement is restricted in the present design codes. In this study, the possibility of the yield strength increase in shear reinforcement is evaluated according to ACI318-08, EC2-02 and CSA-04 by comparing the experimental and calculated results. Three cases were used to analyze the shear strength of the beam. One had no limitation in the yield strength of shear reinforcement, another had restriction on the yield strength of shear reinforcement, and the other had a restriction on the yield strength of shear reinforcement and the shear reinforcement ratio. The study results showed that the case with unlimited shear reinforcement yield strength predicted the test result better than other two cases. Even though the rebar yield strength higher than the strength required in present code was applied to existing shear design equation, the result was reasonable. Therefore, the design equation seemed to be appropriate even if the high-strength shear reinforcement is used in practice based on the existing shear design method.
Keywords
high strength shear reinforcement; yield strength of shear reinforcement; ACI318-08; EC2-02; CSA-04;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Choi, I. J., "Structural Behavior of Reinforced Concrete Beams Using High Strength Shear Reinforcement," Master's Thesis, Sungkyunkwan University, 2010, pp. 8-9.
2 Lee, J. Y., Choi, I. J., and Kang, J. E., "Evaluation of the Maximum Yield Strength of Steel Stirrups and Shear Behavior of RC Beams," Journal of the Korea Concrete Institute, Vol. 22, No. 5, 2010, pp. 711-718. (doi: http://dx.doi.org/10.4334/JKCI.2010.22.5.711)   과학기술학회마을   DOI   ScienceOn
3 American Concrete Institute, Building Code Requirements for Structural Concrete (ACI 318M-08) and Commentary, ACI, 2007, pp. 155-167.
4 CEN, Eurocode 2: Design of Concrete Structures, European Committee for Standardization, 1992, pp. 88-98.
5 Canadian Standards Association, Design of Concrete Structures, CSA, 2004, pp. 53-65.
6 Lee, J. H., "Evaluation of Eurocode 2 Shear Design Provisions," Master's Thesis, Chonnam National University, 2011, pp. 36-57.
7 Lee, J. Y. and Hwang, H. B., "Maximum Shear Reinforcement of Reinforced Concrete Beams," ACI Structural Journal, Vol. 107. No. 5, 2010, pp. 580-588.
8 Guralnick, S. A., "High-Strength Deformed Steel Bars for Concrete Reinforcement," ACI Journal, Vol. 57, No. 3, 1960, pp. 241-282.
9 Clark, A. P., "Diagonal Tension in Reinforced Concrete Beams," ACI Journal, Vol. 48, No. 10, 1951, pp. 145-156.