• Title/Summary/Keyword: ACI 318-14

Search Result 47, Processing Time 0.035 seconds

Short- and long-term deflections of RC building structures influenced by construction processes

  • Alvarado, Yezid A.;Buitrago, Manuel;Gasch, Isabel;Dominguez, Maria N.;Cipagauta, Miguel A.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.173-181
    • /
    • 2017
  • This paper analyzes the influence of the construction process on short- and long-term deflections on a reinforced concrete structure poured on-site by a portable industrialized system. A parametric analysis was carried out by the Finite Elements Method (FEM) that considered: a) type of construction process with reshoring or clearing (partial striking); b) the number of successively shored floors and c) the number of shores used on each floor. All three factors were especially important for the values of short- and long-term deflections, which were highest in the reshoring processes with the lowest number of successively shored floors and the lowest number of shores per floor. Deflections obtained were compared with the limits laid down by ACI 318-14 and as calculated by this code's simplified method. The long-term deflections were seen to be almost double than those obtained by applying the ACI 318-14 code's simplified method and in some cases these deflections were above the established limits. It can thus be concluded that the load history of a building under construction should be taken into account in order to satisfy a structure's in-service conditions and durability.

Seismic repair of reinforced concrete beam-column subassemblages of modern structures by epoxy injection technique

  • Tsonos, Alexander G.
    • Structural Engineering and Mechanics
    • /
    • 제14권5호
    • /
    • pp.543-563
    • /
    • 2002
  • The use of the epoxy pressure injection technique to rehabilitate reinforced concrete beam-column joints damaged by strong earthquakes is investigated experimentally and analytically. Two one-half-scale exterior beam-column joint specimens were exposed to reverse cyclic loading similar to that generated from strong earthquake ground motion, resulting in damage. Both specimens were typical of new structures and incorporated full seismic details in current building codes. Thus the first specimen was designed according to Eurocode 2 and Eurocode 8 and the second specimen was designed according to ACI-318 (1995) and ACI-ASCE Committee 352 (1985). The specimens were then repaired with an epoxy pressure injection technique. The repaired specimens were subjected to the same displacement history as that imposed on the original specimens. The results indicate that the epoxy pressure injection technique was effective in restoring the strength, stiffness and energy dissipation capacity of specimens representing a modem design.

확대단면에서의 띠철근 배근 방법에 따른 보강 기둥의 중심 축하중 거동 평가 (Evaluation of Axial Behavior of Columns Strengthened with Different Transverse Reinforcements in Jacket Section)

  • 황용하;양근혁;심재일;최용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.81-88
    • /
    • 2018
  • 이 연구에서는 실제 단면크기를 갖는 철근 콘크리트 기둥의 내진보강을 위한 단면확대 공법에서 효율적인 띠철근 배근 방법을 평가하였다. 비내진 상세를 갖는 기존 기둥의 단면크기는 $450{\times}450mm$이며, 단면확대 보강기둥의 단면크기는 $750{\times}750mm$이다. 확대 단면에서의 폐쇄형 외부 띠철근 배근을 위해 ㄷ-형 띠철근의 겹칩이음 및 철근 선조립 공법을 제시하였으며, 보조 띠철근으로서 크로스타이 앵커링 시공 및 V-타이를 고려하였다. 실험 결과, 무보강 기둥 및 ㄷ-형 외부 띠철근을 적용한 보강기둥의 압축내력은 ACI 318-14의 공칭내력과 비슷한 수준인 반면 철근 선조립 공법을 적용한 기둥의 압축내력은 ACI 318-14의 공칭내력 대비 1.25배 높았다. 특히 철근 선조립 공법을 적용한 보강 기둥의 압축 연성비는 크기효과에 의한 연성비 저하 가능성에도 불구하고 기존 기둥에 비해 139% 증가하였다. 즉, 제시된 철근 선조립 공법은 단면확대 보강기둥에서 주철근 조기 좌굴방지 및 콘크리트 구속에 효율적인 띠철근 상세로 평가될 수 있었다.

고강도 철근콘크리트 깊은 보의 전단거동 및 ACI 전단설계 기준과의 비교 (Shear Behavior of High-Strength Concrete Deep Beams and Comparisons with ACI Shear Design Provisions)

  • 정헌수;양근혁;함영삼
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.874-882
    • /
    • 2002
  • 현재, 깊은 보의 전단설계는 보통강도 콘크리트를 사용한 일반 보의 사인장 균열내력에 대한 실험식인 ACI 기준에 기본을 두고 시행되고 있지만, 고강도 철근콘크리트 깊은 보의 전단거동에 대한 자료는 매우 제한적이다. 따라서, 본 실험연구의 목적은 고강도 철근콘크리트 깊은 보의 전단거동을 이해하고 ACI 설계 기준의 안전율을 파악하기 위한 것이다. 상부 2점 대칭하중을 받는 22개의 고강도 콘크리트 깊은 보의 전단내력에 대한 실험결과를 나타내었다. 콘크리트 압축강도는 800kgf/$\textrm{cm}^2$이며, 주요 변수로는 전단경간비, 전단철근의 양 및 배근 형태 등이다. 실험결과로부터 전단철근의 전단저항에 대한 효율성은 ACI 기준에서 제시하는 순 경간깊이비(1n/d) 보다는 전단경간비가 크게 관계되었으며 전단경간비가 0.75 이상에서 수직 전단철근이 수평 전단철근보다 전단저항에 더 효율적이었다. 고강도 철근콘크리트 깊은 보의 전단내력을 예측하기 위하여 실험결과들과 전단마찰이론에 근거해서 ACI 기준식을 수정, 제시하였다.

초고강고 RC보의 휨거동 (The flexural of Ultra High Strength Reinforced Concrete Beams)

  • 정철규;조인철;안종문;이광수;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.475-482
    • /
    • 1997
  • This study reports the results of flexural test on 6 specimens for maximum reinforcement ratio and 4 specimens for minmum reinforcement ratio with concrete compressive strength 1,000, 1,200 kg/$\textrm{cm}^2$ . The major test variables for the reinforcement ratio designed 0.55$\rho_b$, 0.65$\rho_b$, 0.75$\rho_b$ for maximurm reinforcement ratio test 14/fy $\sqrt[0.72]{\rho}\acute{f}_c$ / $f_y$ for minimum reinforcement ratio test. The test results were compared with ACI 318-95 Code. In the Ultra High Strength Concrete beam, the maximum reinforcement ration should be less than 0.6$\rho_b$ for ductile behavior and the existing minimum reinforcement ratio by ACI Building Code is Sufficiently safe.

  • PDF

단기하중하의 국내 합성 더블티 슬래브 댑단부 전단거동 평가 (Evaluation on Shear Behaviors of the Dapped Ends of Domestic Composite Double Tee Slabs under the Short-Term Loading)

  • 유승룡
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.774-781
    • /
    • 2002
  • 본 연구에서는 국내에서 활용하고있는 지간거리 l0m인 실물크기 4개의 싱글티 슬래브의 댑 단부에 대하여 8번의 전단실험을 실행하였다. 시험체는 국내 규준의 주차장을 위한 활하중 500kgf/$m^2$와 매장용도를 위한 활하중 1,200 kgf/$m^2$을 적용하여 설계하였다. 강도설계규준을 모두 만족시키면서 시험체에 적용시킨 변수는 걸이철근의 배근방법을 다르게하여 적용시켰다. 현재 국내에서 활용하는 PCI 배근방법에의한 단면과, 90$^{\circ}$절곡배근, 60$^{\circ}$절곡배근에 대한 각 실험결과를 비교 분석하였다. 1) 5mm깊이 빗질로 거칠게 마감한 플랜지 상부의 모든 시험체는 종국파괴까지 토핑콘크리트와 일체 거동하였다. 강선의 정착구 파괴로 인한 조기 파괴된 하나의 시험체를 제외하고서 주어진 강도규준 설계를 대체로 만족시켰다. 2) 걸이철근의 여러 가지 형태를 변수로 두어 실험한 결과 복부 전단균열과 수직으로 배치된 60$^{\circ}$절곡 배근형태의 시험체가 사용하중과 종국하중에서 가장 우수한 결과를 나타냈으며, PCI 형태의 일반배근, 90$^{\circ}$절곡배근의 순으로 전단성능이 좋게 평가되었다.

전단경간비와 주인장철근비가 철근콘크리트 보의 최소전단철근비에 미치는 영향 (Effects of Shear Span-to-depth Ratio and Tensile Longitudinal Reinforcement Ratio on Minimum Shear Reinforcement Ratio of RC Beams)

  • 이정윤;김욱연;김상우;이범식
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.795-803
    • /
    • 2004
  • 현행 구조설계기준식에서는 취성적으로 파괴하는 최소전단보강철근 파괴를 방지하기 위하여 철근콘크리트 보에 최소전단보강철근을 배근하도록 규정하고 있다. 최소전단철근비는 콘크리트의 압축강도와 함께 주인장철근비와 전단경간비에 영향을 받는다. 이 연구에서는 주인장철근비와 전단경간비가 철근콘크리트 보의 최소전단철근비에 미치는 영향을 파악하기 위하여 14개의 철근콘크리트 보를 실험하였다. 실험에 의하면 전단 여유율은 주인장철근비가 증가할수록 증가하였고, 전단경간비가 증가할수록 감소하였다. 실험 결과는 ACI 318-02 기준식과 선행 연구의 제안식과 비교되었다.

프리스트레스트 와이어로프를 사용한 RC 벽체의 단부 경계요소 내진보강 평가 (Evaluation of Seismic Strengthening Approach at the Boundary Elements of RC Walls using Prestressed Wire Rope Units)

  • 권혁진;양근혁;변항용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.56-63
    • /
    • 2018
  • 이 연구에서는 연성중심의 보강을 위하여 벽체의 양단부에서 경계요소를 형성하는 내진 보강공법이 적용된 벽체의 반복 휨 거동을 평가하였다. 벽체 경계요소에서 구속효과를 위한 횡보강은 프리스트레스트 와이어로프를 사용하였다. 주요 변수는 제시된 단면 확대공법의 보강 높이로 하였다. 최소 보강 높이는 보강 벽체와 기존 벽체의 모멘트 분포의 비교로부터 결정하였다. 실험결과, 제시된 보강방법은 벽체의 휨 강성 및 연성향상에 매우 효율적이었는데, 최대내력 시 강성과 최대내력의 80%지점에서 산정한 일손상지수는 무보강 벽체에 비해 각각 평균 46%와 210% 증가하였다. 보강높이가 벽체의 일손상지수 증가에 미치는 영향은 보강높이가 $2.0l_w$ 이상일 때 중요하지 않았다. 보강된 벽체의 휨 내력은 ACI 318-14에서 제안하는 등가응력블록을 통한 예측 값보다 22% 이상 높았다.

격자형 강합성 바닥판 이음부의 전단내력 평가 (Shear Resistance Evaluation of Steel Grid Composite Deck Joint)

  • 신현섭;박기태
    • 한국산학기술학회논문지
    • /
    • 제14권10호
    • /
    • pp.5290-5298
    • /
    • 2013
  • 본 논문에서는 프리캐스트 방식으로 제작 가능한 격자형 강합성 바닥판의 이음부에 기계식 연결방식을 적용하고자 콘크리트 전단키와 고장력볼트로 구성되는 이음부에 대해 Push-out 시험으로 전단내력을 구하였으며, 이를 전단마찰 이론에 근거한 이론식 및 설계식과 비교함으로써 전단내력을 평가하였다. 분석결과에 따르면, 이음부 접합면을 에폭시로 부착한 경우가 전단키를 강판으로 보강한 경우 보다 약 10% 정도 더 큰 전단내력을 갖는 것으로 나타났으나, 실험체간 전단내력의 편차는 전단키를 강판으로 보강한 경우가 더 작게 나타났다. 실험결과를 계산식 및 설계식과 비교한 결과, 기존 설계식으로 안전하게 설계될 수 있음을 알 수 있었다. 그러나, ACI-318에 의할 경우 이음부 전단내력이 과소평가되기 때문에 LRFD에서 제시된 설계식의 적용이 더 적당한 것으로 분석되었다.

횡하중을 받는 RC 무량판 구조의 슬래브 모델링 기법 (Modeling Method of Slabs in RC Flat-Plate Structures Under Lateral loading)

  • 최정욱;송진규;이수곤;김진상
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.615-622
    • /
    • 2002
  • 철근콘크리트 무량판 구조의 내력 및 변위를 합리적으로 예측하기 위해서는 슬래브의 휨 강성을 고려한 해석모델이 필요하다. FEMA 273과 ACI 318-99에서는 횡 하중에 대한 슬래브의 해석모델들을 제시하고 있으나 실제적인 적용 방법론은 언급하고 있지 않다. 본 연구에서는 무량판 슬래브의 모델링 방법론을 정립하고 이를 내진설계에 어떻게 적용할 것인가에 대하여 연구하였다. 연구결과는 다음과 같다. 1) 무량판 구조의 3차원 해석시 슬래브의 휨 강성을 적절히 고려하기 위해서는 본 연구진이 제시하는 유효보폭 모델을 적용하는 것이 바람직하다. 2) 예제 무량판 건물 해석에서 슬래브의 균열효과를 고려한 유효보폭을 이용할 경우 해석결과는 횡변위에 대하여 상한값을 나타낸 반면 유효보폭 계수만을 고려한 모델은 접합부 불균형 모멘트에 대하여 상한값의 결과를 나타냈다.