• Title/Summary/Keyword: AC7A

Search Result 878, Processing Time 0.027 seconds

A study on single body design of optical current sensor and optical voltage sensor (광전류/광전압 센서의 일체화 설계에 관한 연구)

  • 김영수;김요희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1596-1603
    • /
    • 1996
  • A single body type of fiber-optic current and voltae sensor using a rare earth doped YIG and a bismuth silicon oxide single crystsl is proposed, which is used for simultaneous measurement of the AC electric current and AC electric voltage over the trasmission lines. Experimental results showed that the fiber-optic current sensor has the maximum 7.5% error within the current range of 0A to 400A, and the fiber-optic voltage sensor has the maximum 0.87% error within the current range of 0V to 400V. The output waveforms of proposed fiber-optic sensor system has a good agreement with output waveforms of conductor current and voltage. Experimental results proved that the output of fiber-optic current sensor is not affected by the electric voltage applied to the fiber-optic voltage sensor, and also, that the output of fiber-optic voltage sensor is not affected by the electric current applied to the fiber-optic current sensor.

  • PDF

Analysis of fusogenic activity of autographa californica nuclear polyhedrosis virus (Ac NPV) gp64 envelope glycoprotein

  • Kim, Hee-Jin;Yang, Jai-Myung
    • Journal of Microbiology
    • /
    • v.34 no.1
    • /
    • pp.7-14
    • /
    • 1996
  • Teh baculovirus gp64 glycoprotein is a major component of the envelope of budded virus (BV) and has been shown that it plays an essential role in the infection process, especially virus-cell membrane fusion. We have cloned Autographa californica Nuclear Polyhedrosis Virus (AcNPV) gp64 protein were examined for membrane fusion activity by using a synchtium formation assay under various conditions. The optimal conditions required for inducing membrane fusion are 1) form pH 4.0 to 4.8 2) 15 min exposure of cells to acidic pH 3) at least 1 .mu.g of gp64 cloned plasmid DNA per 3 * 10$^{6}$ cells 4) and an exposure of cells to acidic pH at 72 h post-transfection. In order to investigate the role of hydrophobicity of the gp64 glycoprotein for the membrane fusion, the two leucine residues (amino acid position at 229 and 230) within hydrophobic region I were substituted to alanine by PCR-derived site-directed mutagenisis and the membrane fusion activity of the mutant was anlaysed. The gp64 glycoprotein carrying double alamine substitution mutation showed no significant difference in fusion activity. This result suggested that minor changes in hydrophobicity at the amino acid position 229 and 230 does not affect the acid-induced membrane fusion activity of the gp64 glycoprotein.

  • PDF

Alternating Current (AC) Powered LED Lighting Technology with Constant Brightness (빛의 밝기가 일정한 교류 구동 LED 조명기술)

  • Lee, Dong Won;Ahn, Ho-Myoung;Kim, Byungcheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.466-470
    • /
    • 2022
  • In order to widely disseminate LED lighting, LED lighting technology that directly uses AC commercial power has been recently introduced. AC powered LED lighting technology has a problem in that the light brightness of the LED changes because the voltage applied to the LED and the current flowing through the LED continuously change. In this study, when the LED current is greater than the design current, the current control signal generated by the controller is supplied to the current source to supply only the design current to the LED by increasing the voltage drop at the current source. If it is smaller than the design current, the controller is adjusted so that the current is supplied only to the LED without a voltage drop in the current source. It can be seen that the higher the maximum rectified voltage, the faster the lighting time of the LED light emitting block is, so that the power factor of the LED lighting is improved. The LED lighting technology proposed in this study enables LED lighting with constant light brightness, reduced power consumption, and long lifetime.

SR144528 as Inverse Agonist of CB2 Cannabinoid Receptor

  • M.H. Rhee;Kim, S.K.
    • Proceedings of the Korean Society of Embryo Transfer Conference
    • /
    • 2002.11a
    • /
    • pp.96-96
    • /
    • 2002
  • We examined the role of SR 144528 (N-[-(1S-endo-1,3,,3-trimethyl-bicycle[2, 2, 1 ] heptan-2-y1]-5-(-4-chloro-3-mothyl-phenyl)-(4-methylbenzyl)-pyrazole-3- carboxamide) in the modulation of certain AC isoforms in transiently transfected COS-7 cells. We found that CB2 in COS cells has a constitutive activity, and thus leading to inhibition of AC-V activity even in the absence of agonist. In addition, this constitutive modulation of AC is reversed by SR144528. It is now well established that several G protein-coupled receptors can signal without agonist stimulation(constitutive receptors). Inverse agonists have been shown to inhibit the activity of such constitutive G protein-coupled receptor signaling. Agonist activation of the G$\_$i/o/-coupled peripheral cannabinoid receptor CB2 normally inhibits adenylyl cyclase type V and stimulates adenylyl cyclase type II. Using transfected COS cells, we show here that application of SR144528, an inverse agonist of CB2, leads to a reverse action (stimulation of adenylyl cyclase V and inhibition of adenylyl cyclase II). This inverse agonism of SR144528 is dependent on the temperature, as well as on the concentration of the cDNA of CB2 transfected. Pertussis toxin blocked the regulation of adenylyl cyclase activity by SR 144528.

  • PDF

Metalloproteinase Plays a Role in Mucin Secretion (Mucin 분비에 영향을 미치는 Metalloproteinase)

  • Oh, Yeon-Mok;Choi, Hee Jin;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.289-296
    • /
    • 2004
  • Background : Mucus hypersecretion in the patients with airway diseases represents poor prognosis as well as discomfort. However, there is no known therapy for its effective control. One important component of mucus is mucin, a glycosylated protein, which endows mucus with viscosity. We studied whether a proteinase has a role in mucin secretion and if so, which. Methods : (1) Inhibition of mucin secretion Group-specific proteinase inhibitors were tested to evaluate whether a proteinase belonging to a group of proteinases plays a role in mucin secretion. Phenylmethylsulfonyl fluoride(PMSF, a serine proteinase inhibitor), E-64(a cysteine proteinase inhibitor), Pepstatin(an aspartic proteinase inhibitor) and 1, 10-Phenanthroline(a metalloproteinase inhibitor) were treated into the Calu-3 cell line for 24 hours. The enzyme linked immunoabsorbant assay(ELISA) for MUC5AC was performed to evaluate the amount of mucin secretion and to compare with a control. (2) Stimulation of mucin secretion Matrix metalloproteinase-9(MMP-9), MMP-12 and TACE(TNF-alpha converting enzyme), which are known to be related with airway diseases, were used to be treated into Calu-3 for 24 hours. ELISA for MUC5AC was performed to evaluate the amount of mucin secretion and to compare with the controls. Results : (1) PMSF($10^{-4}M$), E-64($10^{-4}M$), Pepstatin($10^{-6}M$) and 1, 10-Phenanthroline($10^{-4}M$) reduced the MUC5AC secretion by $1{\pm}4.9%$(mean${\pm}$standard deviation; P=1.0 compared with the control), $-6{\pm}3.9%$(P=0.34), $-13{\pm}9.7%$(P=0.34) and $41{\pm}8.2%$(P=0.03), respectively. (2) The amounts of MUC5AC secretion stimulated by MMP-9(250ng/ml), MMP-12(100ng/ml) and TACE(200ng/ml) were $103{\pm}6%$(P=0.39), $102{\pm}8%$(P=1.0) and $107{\pm}13%$(P=0.39), respectively, compared with the controls. Conclusion : Metalloproteinase(s) is (are) suggested to play a role in mucin secretion. It appears that metalloproteinases, other than MMP-9, MMP-12 or TACE, affect the mucin secretion in this in vitro model.

Improvement of Electrochemical Characteristics and Study of Deterioration of Aluminum Foil in Organic Electrolytes for EDLC

  • Lee, Mun-Soo;Kim, Donna H.;Kim, Seung-Cheon
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.9-19
    • /
    • 2018
  • The anodic behavior of aluminum (Al) foils with varying purity, capacitance, and withstand voltage in organic electrolytes was examined for EDLC. The results of cyclic voltammetry (CV) and chronoamperometry (CA) experiments showed that the electrochemical stability improves when Al foil has higher purity, lower capacitance, and higher withstand voltage. To improve the electrochemical stability of EDLC current collectors made of low-purity foil (99.4% Al foil), the foil was modified by chemical etching to reduce its capacitance to $60{\mu}F/cm^2$ and forming to have withstand a voltage of 3 Vf. EDLC cells using the modified Al foil as a current collector were made to 2.7 V with 360 F, and a constant voltage load test was subsequently performed for 2500 hours at high temperature under a rated voltage of 2.7 V. The reliability and stability of the EDLC cell improved when the modified Al foil was used as a current collector. To understand the deterioration process of the Al current collector, standard cells made of conventional Al foil under a constant voltage load test were disassembled, and the surface changes of the foil were measured every 500 hours. The Al foil became increasingly corroded, causing the adhesion between the AC coating layer and the Al foil to weaken, and it was confirmed that partial AC coating layer peeling occurred.

AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.200-203
    • /
    • 2012
  • Epoxy/mica composite was synthesized, in order to use it as an impregnation resin in a vacuum pressure impregnation (VPI) process, for manufacturing a high voltage rotary machine. The average particle size of the mica was 5~7 ${\mu}m$ and its content was 0, 20, 30 and 40 wt%. A plasticizer or a low molecular aliphatic epoxy was also used, to decrease the viscosity of the composite. The AC electrical breakdown strength was estimated in sphere-to-sphere electrodes, and the electrical breakdown data were estimated by Weibull statistical analysis. The electrical breakdown strength became higher with the addition of mica; and that of the system with 20 wt% mica was highest. The electrical breakdown strength of the system with an aliphatic epoxy was higher than that of the system with a, plasticizer.

Ordinal Measure of DCT Coefficients for Image Correspondence and Its Application to Copy Detection

  • Changick Kim
    • Journal of Broadcast Engineering
    • /
    • v.7 no.2
    • /
    • pp.168-180
    • /
    • 2002
  • This paper proposes a novel method to detect unauthorized copies of digital images. This copy detection scheme can be used as either an alternative approach or a complementary approach to watermarking. A test image is reduced to 8$\times$8 sub-image by intensity averaging, and the AC coefficients of its discrete cosine transform (DCT) are used to compute distance from those generated from the query image, of which a user wants to find copies. Copies may be Processed to avoid copy detection or enhance image quality. We show ordinal measure of DCT coefficients, which is based on relative ordering of AC magnitude values and using distance metrics between two rank permutations, are robust to various modifications of the original image. The optimal threshold selection scheme using the maximum a posteriori (MAP) criterion is also addressed.

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

A comparison of different modes of load carriage : an evaluation

  • Lee, K.S.
    • Proceedings of the ESK Conference
    • /
    • 1992.10a
    • /
    • pp.104-112
    • /
    • 1992
  • The objectives of this study were: (a) to find the maximum ac- ceptable weight which can be carried for 8 hours using a psycho- physical method for front, side (one hand and two hands) and back carrying, and (b) to develop models which could predict the ac- ceptable maximum weight in carrying using isometric strength and anthropometric data. A series of laboratory experiments were conducted to find the maximum acceptable weight in front side and back carrying. Six college students participated in the experiment. It was found that subjects were willing to carry the heaviest load using two-hand side carrying (average maximum acceptable weight: 7.76 kg). Back carrying was the close second with 6.62 kg. Also, there was a significant difference (p< 0.01) in maximum acceptable weight for carrying between one-hand (4.40kg) and two-hand side carrying.

  • PDF