• 제목/요약/키워드: AC source

검색결과 723건 처리시간 0.028초

부분공진형 고역률 승강압 AC-DC 컨버터 (A New partial resonant buck-boost AC-DC converter for high power factor)

  • 신현식;서기영;권순걸;곽동걸;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.512-515
    • /
    • 1994
  • This paper propose the high power factor and efficiency buck-boost AC-DC converter because the input current is made sinusoidal wave in single phase alternating current source. The proposed converter is able to minimize switching loss by the partial resonant switching which is for switching devices to operate the zero voltage switching (ZVS) or zero current switching(ZCS) without increasing their voltage and current stresses.

  • PDF

고전압 중전기기용 에폭시 수지 3종에 대한 교류트리잉 파괴특성 (Characteristics of AC Treeing for Three Epoxy Resins for High Voltage Heavy Electric Machine Appliances)

  • 박재준
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1322-1329
    • /
    • 2018
  • In this paper, the reliability test of three kinds of epoxy resin for GIS Spacer, which is a high voltage based heavy electric machine, AC electrical treeing experiments were performed. Three types of epoxy resins, Araldite B41, CT 5531 CI and B46, have slight viscosity differences. An non-uniform electric field, E = 1149.4 kV/mm, as the needle to plate electrode, a power source with a frequency of 1 kHz was applied to the tree electrode for accelerated deterioration. The treeing phenomena of the three kinds of epoxy resin all initiated, propagated, and destroyed by the branch tree. Epoxy Resin B46 was 145 times longer than B41 and 53 times longer than CT 5531CI. I think that the choice of epoxy resin is very important in choosing high voltage heavy electric machine insulation materials.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

불평등 전계하의 제조공기(I-Air)에 대한 절연파괴 특성 (Breakdown Characteristics of Imitation Air under Non-Uniform Fields)

  • 이창욱;이창훈;최은혁;윤대희;장승호;김정배;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.385-388
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using non-uniform fields(Needle--Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

3상 제어컨버터의 노치법에 의한 출력과 입출력의 저고조파 제거 (Low-Frequency Harmonic Eliminations on DC/AC Sides of a 3 Phase-Controlled Converter)

  • 홍성태;권순결;이현우;서기영;임근희
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.906-915
    • /
    • 1994
  • Line-Current harmonics resulting from ac to dc power conversion interfere with power system operation and reduce power factor, hence resulting in increasing power source unnecessarily. This study describes a 3 phase phase-controlled converter eliminating low frequency harmonics in the output by inserting notches. Notch points are calculated by Newton-raphson method, The impacts of the choppings on ac and dc sides are analyzed in the steady state. Potential applications of the study are dc motor controls, high power dc power supplies for telecommunications, static var compensators and HVDC.

  • PDF

로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터 (The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber)

  • 문상필;서기영;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

저압 AC회로의 MOV 적용방안 연구 (A Study on the Utilization of Metal Oxide Varistor for Low-Voltage AC Circuits)

  • 최효열;이원빈;강영석;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1822-1824
    • /
    • 1996
  • Damage and upset of control and communication equipment due to transient overvoltages which occur due primarily to internal switching surge and external lightning surge are an important problems in electromagnetic compatibility(EMC). In this paper, we analyzed operation characteristic of metal oxide varistor widely used low voltage AC line using the electromagnetic transients program(EMTP) and compare it with experimental results and also, we modeled combination generator producing $1.2/50{\mu}s$ open circuit voltage and $8/20{\mu}s$ short circuit current as a source which is critical in calculating operation characteristic. Simulation results showed that most of Transient energy consumes at MOV located in service entrance side than load side, and it showed similar to experimental results. Therefore, entrance side MOV should be selected more energy capacity than that of load side MOV.

  • PDF

$PRS^2$를 사용한 3상 AC/DC 컨버터의 부하특성 (Load Characteristic of Three-phase AC/DC Boost Converter Using a $PRS^2$.)

  • 강욱중;이현우;서기영;백수현;한경희;전중함
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.438-440
    • /
    • 1997
  • This paper proposed a partial resonant switching three-phase high power factor converter using a $PRS^2$(Partial Resonant Soft Switch). The proposed converter has a merit of simple controlled circuit because the input current control DCM(Discontinuous Conduction Mode). And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

A Digitally Controlled Three-Phase Cycloconverter Type High Frequency AC Link Inverter Using Space Vector Modulation

  • Sha, Deshang;Qin, Zian;Wu, Dan;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.28-36
    • /
    • 2011
  • In this paper, a three phase cycloconverter type high frequency AC link inverter is discussed. The configuration consists of a high frequency full-bridge inverter and a high frequency transformer followed by a three phase cycloconverter whose switch is composed of anti-series connected MOSFETs with a common source. A simple digital control strategy based on space vector modulation (SVM) and repetitive control for the cycloconverter is proposed although its input voltage is a high frequency AC pulse. The operation principle of the proposed control strategy is analyzed and the equivalent working modes during one interval are also presented. The effectiveness of the proposed control strategy is verified through Matlab/Simulink simulations and experiments on a 1.45kW prototype.

외부자계 영향에 따른 HTS 선재의 직$\cdot$교류 통전 특성 (DC and AC current transport characteristics of HTS tapes with external magnetic field)

  • 임성우;최용선;최효상;황시돌;정영호
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2003
  • HTS(High Temperature Superconductor) tapes have dependence on critical characteristics such as electric, magnetic field and temperature. In order to confirm these effects, we examined the current transport characteristics of HTS tapes. First, after being fed DC and AC, the dependence of HTS tapes of 10cm on external magnetic field was investigated. On centeral region of HTS tape, about 1cm, external magnetic field was applied. Second, after applying DC of 50A to HTS tapes, we applied time variable magnetic field about 100mT and investigated the quench characteristics. Finally, AC, which is about 10 times of I$_{c}$, was applied to HTS tapes and over current characteristics were investigated. The data acquired in this study will be used as a source for the study of HTS cable conductor which is supposed to carry on.n.

  • PDF