• Title/Summary/Keyword: AC permeability

Search Result 45, Processing Time 0.022 seconds

Monitoring of Degradation Process of Commercial ME Tapes under High Humidity Environment by AC Impedance Techniques

  • Take, Seisho;Shimanuki, Akiko;Itoi, Yasuhiko;Okuyama, Masaru
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.194-197
    • /
    • 2004
  • The corrosion resistance of several kind of ME (Metal Evaporated) tape has been investigated both in mild sulfuric acid solution and NaCl solution by electrochemical impedance spectroscopy. It was found that the degradation of ME tapes was accelerated with increasing the concentration of sulfuric acid. There was no significant change in corrosion resistance when the concentration of NaCl was under 3.5 wt%. However, the impedance value decreased when the concentration of NaCl was up to 10 wt%. The degradation of backside of ME tapes was also investigated by AC impedance measurements. The results showed that the impedance behavior of backside plastic film changed with the concentration of sulfuric acid even at the beginning of immersion, implying the changing of the permeability for the backside of ME tapes. It was also found that the corrosion resistance of DVC (Digital Video Cassette) ME tape was better that that of Hi-8mm ME tapes in sulfuric acid solutions. Also, the backside of DVC ME tape showed better water resistance than that of Hi8 ME tapes.

Oral Mucosal Adhesive Tablets of Omeprazole (오메프라졸 구강점막 부착정제에 관한 연구)

  • Jung, Jae-Hee;Choi, Han-Gon;Park, Sun-Joo;Ryu, Jei-Man;Yoon, Sung-June
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.2
    • /
    • pp.133-137
    • /
    • 1997
  • Buccal absorption test of omeprazole in human was performed to determine the permeability of the drug molecule through oral mucous membrane. Oral mucosal adhesive tablets of omeprazole were prepared by compressing the omeprazole with a mixture of sodium alginate and hydroxypropylmethyl cellulose (HPMC) as bioadhesive polymers, magnesium oxide (MgO) as a stabilizer and sodium carboxymethyl cellulose (Na CMC) or cros-carmellose sodium (Ac-Di-Sol) as disintegrants. The bioadhesive force, stability in saliva and release characteristics of the tablets were evaluated. Omeprazole was absorbed about 23% in 15 min through human buccal mucous membrane. Furthermore, omeprazole was stable in saliva for more than 8 hrs when MgO was added to the tablet as the amount of 2.5 fold of omeprazole. The release rate of omeprazole was increased with increasing the amount of sodium alginate in the tablet. From these results, it is suggested that tablets composed of [omeprazole/HPMC/sodium alginate/MgO/Ac-Di-Sol and/or Na CMC (20/6/24/50/10) (mg/tablet)] are potential candidate for buccal drug delivery system.

  • PDF

Ultra Low Field Sensor Using GMI Effect in NiFe/Cu Wires

  • Kollu, Pratap;Kim, Doung-Young;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.35-39
    • /
    • 2007
  • A highly sensitive magnetic sensor using the Giant MagnetoImpedance effect has been developed. The sensor performance is studied and estimated. The sensor circuitry consists of a square wave generator (driving source), a sensing element in a form of composite wire of a 25 $\mu$m copper core electrodeposited with a thin layer of soft magnetic material ($Ni_{80}Fe_{20}$), and two amplifier stages for improving the gain, switching mechanism, scaler circuit, an AC power source driving the permeability of the magnetic coating layer of the sensing element into a dynamic state, and a signal pickup LC circuit formed by a pickup coil and an capacitor. Experimental studies on sensor have been carried out to investigate the key parameters in relation to the sensor sensitivity and resolution. The results showed that for high sensitivity and resolution, the frequency and magnitude of the ac driving current through the sensing element each has an optimum value, the resonance frequency of the signal pickup LC circuit should be equal to or twice as the driving frequency on the sensing element, and the anisotropy of the magnetic coating layer of the sensing wire element should be longitudinal.

The Magnetic Properties of FeBSiNb Alloy Ribbons with High Glass forming Ability (고 비정질 형성능을 가진 FeBSiNb 합금 리본의 자기적 특성)

  • Noh, Tae-Hwan;Kim, Gu-Hyun
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.154-159
    • /
    • 2002
  • Amorphous FeBSiNb alloy ribbons having bulk glass forming ability and high saturation magnetic flux density were produced by single-roller melt spinning apparatus in the thickness range of 22∼102㎛. With the increase of thickness, the coercive force and squareness ratio decreased, while maximum permeability and AC permeability increased. However electrical resistivity was almost constant. Furthermore refined and complex magnetic domain structure was observed in thicker ribbons owing to the change in internal magnetic anisotropy. For the alloy with the thickness of 81㎛, small coercive force of 24 mOe and high effective permeability of 12,000 at 1㎑ were obtained, those are considered to be better comparing to the conventional soft magnetic amorphous alloys (∼20 ㎛). The good soft magnetic properties of the thick FeBSiNb amorphous alloys were attributed to the decrease in surface pinning effect during wall motion, appearance of perpendicular anisotropy and resulted domain refinement.

The Effects of Co Addition on Glass Forming Ability and Magnetic Properties for FeSiBNb Ribbon Alloys (FeSiBNb 리본 합금의 비정질 형성능과 자기적 특성에 미치는 Co의 첨가 효과)

  • Lee, Tae-Gyu;Noh, Tae-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.3
    • /
    • pp.128-132
    • /
    • 2007
  • The thermal and magnetic properties of amorphous (FeCo)SiBNb ribbon alloys with high glass forming ability have been investigated. The glass forming ability was enhanced by Co substitution in amorphous ($Fe_{1-X}Co_X)_{72}Si_4B_{20}Nb_4$ alloys with the thickness of about $40{\mu}m$. With the increase in Co content, the temperature range of supercooled liquid phase increased indicating the high glass forming ability of the Co-added alloys. Further the ac permeability increased, and the core loss decreased considerably by Co substitution, while small change in $B_8$ (magnetic flux density at 800 A/m) was observed. The frequency characteristics of permeability deteriorated as compared to conventional amorphous ribbon alloys with the thickness of about $20\;{\mu}m$ due to the increased skin effect.

Design of MSR for Magnetic Field Shielding of Low Frequency (저주파 자기장 차폐를 위한 자기차폐실 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.154-159
    • /
    • 2010
  • In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.

The mechanism of the magnetoresistance contribution to the magnetoimpedance effect in thin films

  • Phan, Manh-Huong;Phan, The-Long;Yu, Seong-Cho
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.58-59
    • /
    • 2003
  • We have developed a simple model allowing further clarifications of the magnetoresistance (MR) contribution to the giant magnetoimpedance (GMI) effect in thin films. The theoretical considerations are the following. It is absolutely assumed that a thin film with no magnetic domain structure and a high frequency ac current I = I$\sub$0/e$\^$iwt/ flowing parallel to the Z direction in the plane of the film. The sample has the thickness 2a in the X direction, thus the Y direction in the plane of the sample and perpendicular to the current direction. The transverse permeability ${\mu}$$\sub$Y/ in the Y direction is uniform. In the case of GMI effect, the total impedance Z = R + iX can be written as.

  • PDF

Color Changes according to the Extraction Condition of Caesalpinia sappan Dyestuff II (소목 염료의 추출조건이 색상에 미치는 영향 II)

  • Jeon, Hee-Young;Choi, Se-Min;Ahn, Jeong-Hoo;Jeon, Dong-Won
    • Journal of Fashion Business
    • /
    • v.13 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • By introducing chitosan treatment prior to dyeing, examination was given to the effect of chitosan coated on the surface of fabrics on the color change of dyed fabric based on th e change of ${\Delta}E$, a*, and b* values. At the same time, the dyeing mechanism of Caesalpinia sappan dyestuff was predicted by the investigation of the change of air-permeability ac cording to the chitosan treatment. The change of elution was investigated by the examination of the elution of metallic ions employed as mordants after soaking dyed fabrics in the solution of alkaline perspiration ba sed upon the fact that chitosan carries excellent absorption ability toward metallic ions.

Effects of Heat Treatment on Choke Core Properties in $Fe_{78}Si_9B_{13}$ Amorphous Alloys ($Fe_{78}Si_9B_{13}$ 비정질 합금의 초크 코어 특성에 미치는 열처리 효과)

  • 노태환;장완희
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.191-195
    • /
    • 2000
  • With the object of developing a non-gap choke core, effects of annealing in oxygen atmosphere on magnetic properties for Fe$_{78}$Si$_{9}$B$_{13}$ amorphous alloy were investigated. After annealing for 2 hrs at 440 $^{\circ}C$, optimum magnetic properties for choke core were obtained, where the effective permeability was 180 and was almost constant up to several MHz, and the decrease in permeability upon large DC bias current of 12 A or DC bias magnetic field of 8,000 A/m was very little. Moreover the AC magnetic loss was very low as compared to the conventional choke cores. Upon the optimum annealing, the magnetic hysteresis loop was inclined accompanying the increase of coercive force and the appearance of fine crystallites of $\alpha$-Fe phase. The good choke core properties was considered to be due to the suppression of domain boundary motion and domain refinement by the crystallites.

  • PDF

Fabrication of 13Cr-1.5Nb-Fe Alloy Powder and AC Magnetic Properties of the Sintered Magnetic Core (소결 13Cr-1.5Nb-Fe 합금의 교류 자기 특성)

  • 오환수;김택기;조용수
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.11-15
    • /
    • 2000
  • 13Cr-1.5Nb-Fe alloy powder prepared by water atomizing method is reduced with flowing hydrogen gas. The characteristics of a reduced alloy powder is investigated and magnetic cores formed by using the reduction power sintered in the vacuum of ∼10$\^$-5/ Torr. In order to study on the magnetic cores permeability and power loss in alternating magnetic field are also measured. The result of particle size distribution shows the paticle size is 70 ㎛ at volume fraction of 50 %. The saturation magnetization of the reduced alloy powder is 160 emu/g. The relative peak permeability (H$\_$a/=5Oe) of a magnetic core is 400 and the power loss (B$\_$m/=80G) 0.12 mW/cc at sintering temperature of 1,200 $\^{C}$, 10 ton/㎠ forming pressure, and 1 kHz.

  • PDF