Design of MSR for Magnetic Field Shielding of Low Frequency  

Choi, Hak-Yun (김포대학 IT학부)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.24, no.6, 2010 , pp. 154-159 More about this Journal
Abstract
In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.
Keywords
Magnetic Shielding; Helmholtz Coil; Geomagnetic Field; Permalloy; Eddy Current; AC/DC Shielding;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김기채 외 4인 ‘전자파환경공학’ 대영사, pp.97-98, 2006.
2 유권규 외 4인, '생체신호 측정을 위한 최대의 신호대 잡음비를 가지는 검출코일의 형태와 자기차폐실의 최적 조합', Progress in Superconductivity, 제 9권 1호, pp45-49, 2007.10.   과학기술학회마을
3 식품의약품안전청 고시 제2007-32호, ‘의료기기의 전자파 안전에 관한 공통기준규격’ 2007.5.
4 P. Heinonen, “Properties of a thick-walled conducting enclosure in low-frequency magnetic shielding”, Journey of Physics, Vol.13, No.5, pp.569-560, 1980.   DOI
5 이용호 외 6인, “생체자기계측을 위한 자기차폐실의 설치 및 특성”, 한국자기학회, 제6권 4호, pp.264-271, 1996.8.   과학기술학회마을
6 권종화 외 3인, “헬름홀쯔 코일을 이용한 자기장 차폐 성능 측정 시스템”, 추계 마이크로파 및 전파학술대회 논문집, 제21권 2호, pp.363-366, 1998.9.