• Title/Summary/Keyword: AC losses

Search Result 273, Processing Time 0.026 seconds

Analysis and Comparison of Switching Losses and Temperature using Si and SiC devices applied in Two Stage AC-DC Converter for Battery Pack Testing System (배터리팩 시험기를 위한 2단 구성 AC-DC 컨버터의 Si와 SiC의 손실 및 온도 비교 분석)

  • Seong, Ho-Jae;Choi, Hyeong-Jun;Hong, Seok-Jin;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.397-398
    • /
    • 2016
  • This paper analyzes switching losses, efficiency and temperature depending on Si and SiC devices applied in two stage AC-DC converter. To evaluate the charge and discharge performance and stability of the battery pack, there is a need for a battery pack testing system. To do battery charge and discharge experiment used in battery pack test, A topology, two stage AC-DC converter, has been built. SiC devices more decrease switching losses than that of Si. Also, cooling system was applied in Si and SiC devices. When using SiC devices, it can be confirmed that the size of heat sink is reduced for small loss.

  • PDF

AC Loss Characteristics of Stacked BSCCO-2223 Tapes by Using Magnetization Method (자화법을 이용한 적층된 BSCCO-2223 교류손실 특성의 해석)

  • Kang, Hyoung-Ku;Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo;Kim, Kye-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.262-264
    • /
    • 1999
  • The AC losses of BSCCO-2223 multifilamentary superconducting tapes were measured using magnetization method and compared with the results of theoretically calculated values. In general, AC losses in multifilamentary superconducting tapes could be quantitatively explained by the simple sum of the Hysteresis and Coupling Loss. As a result of experiment, We found that AC losses of multifilamentary superconducting tape increase rapidly in large magnetic field region.

  • PDF

Influence of tape′s arrangements on AC Loss Characteristics in a 3-conductor (테이프 배열이 3본-도체의 교류손실 특성에 미치는 영향)

  • 조영호;허대행;류경우;최병주;황시돌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.260-262
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$, superconducting power cables which consist of a number of Bi-2223 tapes wound on a cylindrical former. In this paper, the ac loss characteristics in the 3-conductor have investigated experimentally. The loss test results indicate that the ac loss is not related to the arrangement of Bi-2223 tapes, contact position and applied frequency. The measured losses in face-to-face arrangement are larger than those in edge-to-edge arrangement. The measured losses in the 3-conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

Analysis of AC Losses in HTS Transformer with Double Pancake Windings (초전도 변압기 교류 손실 해석)

  • Kim Jong-Tae;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.812-814
    • /
    • 2004
  • AC loss is one of the important parameters in (High Temperature Superconducting)HTS AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

  • PDF

Reducing Switching Losses in Indirect Matrix Converter Drives: Discontinuous PWM Method

  • Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1325-1335
    • /
    • 2018
  • This paper presents a discontinuous pulse width modulation (DPWM) method to reduce switching losses in an indirect matrix converter (IMC) drive. The IMC has a number of power semiconductor switches. In other words, it consists of a rectifier stage and an inverter stage for AC/AC power conversion, which are composed of 12 and 6 switching devices, respectively. Therefore, the switching devices of the IMC suffer from high switching losses in the IMC drives. Various topologies to reduce switching losses have been studied by eliminating a number of switches from the rectifier stage. In this study, in contrast to prior research, a DPWM method is presented to reduce the switching losses of the inverter stage. The effectiveness of the proposed method to reduce switching losses in IMC drives is verified by simulations and experimental results.

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

Soft Switching DC-DC Converter for AC Module Type PV Module Integrated Converter (AC 모듈형 태양광 모듈 집적형 컨버터를 위한 소프트 스위칭 DC-DC 컨버터)

  • Youn, Sun-Jae;Kim, Young-Ho;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.247-255
    • /
    • 2013
  • In this paper, a soft switching DC-DC converter for AC module type photovoltaic (PV) module integrated converter is proposed. A push-pull converter is suitable for a low voltage PV AC module system because the step-up ratio of a high frequency transformer is high and the number of primary side switches is relatively small. However, the conventional push-pull converters do not have high efficiency because of high switching losses by hard switching and transformer losses (copper and iron losses) by high turns-ratio of the transformer. In the proposed converter, primary side switches are turned on at zero voltage switching (ZCS) condition and turned off at zero current switching (ZVS) condition through parallel resonance between secondary leakage inductance of the transformer and a resonant capacitor. Therefore the proposed push-pull converter decreases the switching loss using soft switching of the primary switches. Also, the turns-ratio of the transformer can be reduced by half using a voltage-doubler of secondary side. The theoretical analysis of the proposed converter is verified by simulation and experimental results.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

A Study on the Design of the Class E Resonant Rectifier with a Series Capacitor (직력 캐패시터를 가진 E급 공진형 정류기 설계에 관한 연구)

  • 김남호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.343-352
    • /
    • 1998
  • Higher frequency of energy transfer or at least energy conversion has to be used in order to reduce the size of inductors and capacitors required in the power supplies. Conventional PWM switching-mode power supplies have a limitation of operating frequency due to switching losses in the switching transistors and rectifier diodes. Means of reducing switching losses have been developed for high-frequency resonant amplifiers or more exactly dc/ac inverters. Because of smooth current and voltage waveforms resonant convertesrs havelower device switching losses and stresses lower electromagnetic interference(EMI) and lower noise than PWM converters. Therefore in this paper design equations of Classs E resonant low dv/dt rectifier with a series resonant capacitor drived using Fourier series techniques. The theory is compared with simulation results obtained for the rectifier operating at 10[MHz] ac input and 5[V] coutput.

  • PDF

The effect of twisting on microstructure and AC losses of Bi-2223 superconductor tapes (Twisting된 Bi-2223 선재의 미세조직 관찰 및 교류손실 특성평가)

  • 장석헌;임준형;김정호;김규태;주진호;나완수;정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.126-128
    • /
    • 2003
  • The effect of twisting on the microstructure and AC losses of Bi-2223 superconductor tape has been evaluated. Twisting pitches of the tapes are in the range of 12~60 mm and uniformly deformed. The critical current of the tapes was measured to decreased with decreased pitch. This reduction is believed to be due to the irregular interface, poor grain alignment. In addition, AC losses of the tape reduced as the pitch decreased probably due to combined effects of lower critical current and electrically decoupled filament of twisted tape.

  • PDF