• 제목/요약/키워드: AC ground

검색결과 146건 처리시간 0.034초

무절연구간을 위한 열차위치검지방식 검토 (A review of the train position detection method for neutral section with energized condition)

  • 이태훈;이시빈;홍현표;이희순;박기범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

대기압 플라즈마 소스를 이용한 태양전지 도핑에 관한 연구

  • 박종인;김상훈;조태훈;윤명수;권기청
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.255.1-255.1
    • /
    • 2014
  • 태양전지 도핑공정은 대부분 퍼니스(furnace)도핑으로 제작된다. 퍼니스 도핑 공정은 고가의 장비와 유지 비용이 요구되며 국부적인 부분의 도핑은 제한적이다. 또한 도핑 시 온도와 공정 시간이 태양전지의 전기적 특성을 결정짓는 중요한 변수 이다. 그리하여 최근 많은 연구가 진행되는 대기압 플라즈마를 이용하여 도핑공정에 응용하고자 한다. 본 연구에서 대기압 방전 시 전원은 DC-AC 인버터를 사용하였다. 인버터의 최대 출력 전압은 최대 5kv, 주파수는 수십 KHz 이다. Ar 가스는 MFC(Mass Flow Controller)를 사용하여 조절하였다. 대기압 플라즈마를 이용한 태양전지 도핑 시 소스와 ground 거리에 따른 대기압 플라즈마의 방전을 열화상카메라(thermo-graphic camera, IR)로 온도의 변화 측정 및 광학적 발광분광법(Optical Emission Spectroscopy, OES)을 통해 불순물(질소, 산소)을 측정 하였다. 웨이퍼 도핑 후 생성된 웨이퍼를 측정 및 분석을 하였다.

  • PDF

교류전기철도 매설접지방식에서의 레일전위 해석 (Analysis on Rail Potential on the AC Electric Railway Grounding System)

  • 창상훈;오광해;김주락;최규형;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.446-448
    • /
    • 2001
  • Railway electrification results in Electromagnetic Interference, which affects a life and a equipment. Therefore, a plan against EMI must be considered. This study presents accurate simulation to examine a reason rail potential rise and how to design ground connection and draw up a plan of an optimal buried grounding system according to section.

  • PDF

송전용 애자의 장기실증시험 분석 (A Characteristic analysis of EHV insulators on long-term outdoor tests)

  • 최인혁;최장현;정윤환;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.392-396
    • /
    • 2004
  • Experimental equipments for long-term outdoor tests of EHV insulators in outdoor were constructed. The testing insulators have been energized with 89 [kV] phase-to-ground AC voltage under identical condition at station, and the investigation was carried out for leakage current and various environments such as temperature, relative humidity and wind velocity. The test results of leakage current wave trends have forms on distorted waves including harmonics. The porcelain and glass insulators have low leakage current in case of daytime because moisture and humidity have relative low values. In comparison with these conditions, high leakage current was shown at dawn and rainy day due to high humidity. However, leakage current of polymer insulators was shown approximately $129[{\mu}m]$ without relation to the weather due to hydrophobicity on their surface.

  • PDF

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.

LED 가로등 및 경관조명의 직류 누전 특성 분석 (DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting)

  • 김향곤;김동우;최효상
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

KC-100 민간항공기 체계안전성 평가 (System Safety Assessment for KC-100 Civil Aircraft)

  • 강민성;고대우;최낙선;천영성
    • 시스템엔지니어링학술지
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2010
  • KC-100 is a 4 seats, single piston engine, civil aircraft whose type certificate is applied for KAS 23 (FAR 23) for the first time in Korea. Its system safety assessment and analysis have been conducted to meet the minimum safety requirement in KAS 23 and to verify the safety of equipment, system, and installation in accordance with the requirement of ${\S}$23.1309 and the guidelines in FAA AC 23.1309-1D and SAE ARP 4761. This safety assessment begins with the FHA (Functional Hazard Assessment) at aircraft and system level in preliminary design phase, and all of the safety assessment and analysis reports including the preliminary version of SSA (System Safety Assessment) have been prepared during detail design phase. The revised version of these safety reports will be approved by Airworthiness Authority through the ground and flight test phases. In this paper, the safety assessment requirement in ${\S}$23.1309, safety assessment guideline in AC 23.1309-1D, and safety assessment and analysis methods in ARP 4761 will be explained based on the application example for KC-100 development. The experience and knowledge of this system safety assessment for civil aircraft can be applied to commuter aircraft of FAR 23 class or large transport airplane of FAR 25 class.

  • PDF

냉음극 형광램프의 광 전파 (Observation of Light-Propagation along the Tube of Cold Cathode Fluorescent Lamp)

  • 조윤희;김동준;김정현;한상호;조광섭
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.114-126
    • /
    • 2011
  • 냉음극 형광램프의 길이 방향의 발광에 의한 광의 전파를 관측하였다. 직류 및 교류 전압을 인가하여 램프 길이의 일정한 간격으로 광 신호를 측정하였다. 직류 전원을 맥류로 변조한 전압을 인가하여 광 신호를 관측한 결과 교류 전원의 광 신호와 마찬가지로 램프 길이 방향으로 발광의 전파가 분명히 나타난다. 이들 광 신호로부터 램프의 발광이 고전압부에서 접지부로 전파한다는 것을 보여준다. 광 신호의 전파는 타운젠드 방전 전후로 두 가지의 형태로 나타난다. 저 전류 영역에서는 광 신호가 감쇄하여 전파되며, 전파 속도는 약 $10^4{\sim}10^5m/s$이다. 정상 글로우 방전에서는 광 신호의 감쇄 없이 전파 속도는 약 $10^5{\sim}10^6m/s$이다.

헬리콥터 시뮬레이터용 엔진 제어 및 성능 모델링 기법 연구 (Study of Engine Control/Performance Modeling for Helicopter Simulator)

  • 전향식;전대근;최형식;최영규
    • 한국정보통신학회논문지
    • /
    • 제12권12호
    • /
    • pp.2239-2246
    • /
    • 2008
  • 헬리콥터 시뮬레이터용 엔진 제어/성능 모델은 비행 성능과 조종성에 직접적인 영향을 주는 핵심 모델 중 하나로서, 헬리콥터 엔진 설계/제작사로부터 원천 및 모델을 확보하여 개발하는 것이 일반적이다. 본 연구에서는 통상적인 개발 방법을 따르지 않고, 가용한 자원을 활용하여 기본 모델을 구성하고 이를 지상/비행시험 결과와 비교 튜닝하여 검증하는 방법을 채택하였다. 대상 헬리콥터인 KA-32T의 장착 엔진인 TB3-117 엔진의 엔진 제어 모델을 위해 TB3-117 정비교범에 기술되어 있는 엔진의 기능을 검토하여, 모의 대상요소를 분류한 후 모델링을 수행하였다. 엔진 성능 모델은 Piece-wise Linear Model 방법을 사용하였으며, TB3-117 정비 교범에 포함된 엔진 성능 데이터를 활용하여 정상상태 엔진 성능 테이블을 구축한 후 이를 변환 함수를 기반으로 한 동적 모델에 통합하였다. 개발된 엔진 제어 모델 및 성능 모델은 지상/비행 시험 결과와 비교 튜닝하여, 개발 모델이 FAA AC120-63 규격에 적합한 충실도를 보유함을 검증하였다.

비대칭 차동 인덕터를 이용한 2.4-GHz 선형 CMOS 전력 증폭기 (Differential 2.4-GHz CMOS Power Amplifier Using an Asymmetric Differential Inductor to Improve Linearity)

  • 장성진;이창현;박창근
    • 한국정보통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.726-732
    • /
    • 2019
  • 본 연구에서는 차동 구조의 고주파 증폭기를 위한 비대칭 차동 인덕터를 제안하였다. 제안 된 비대칭 차동 인덕터는 증폭기 내 차동 신호 간 위상 오차를 완화하기 위한 것으로서, 차동 인덕터에 형성되는 Center-tap의 위치를 조정하여, 전력 증폭기를 구성하는 구동 증폭기의 차동 신호에서 바라보이는 임피던스가 동일하게 형성 되도록 하였다. 이를 통하여 기존 차동 인덕터를 사용하는 경우 대비 AM-to-AM 및 AM-to-PM 왜곡이 완화됨을 확인 하였다. 제안하는 비대칭 차동 인덕터의 효용성을 확인하기 위하여 180-nm RFCMOS 공정을 이용하여 2.4-GHz CMOS 전력 증폭기를 설계하였으며, EVM 5% 기준 20 dB의 전력 이득과 17 dBm의 최대 선형 출력 전력을 얻었다.