• 제목/요약/키워드: AC System

검색결과 2,743건 처리시간 0.025초

Long Electrode Gap을 가진 Macro Cell에서의 고효율 PDP 특성 연구 (High Efficacy Plasma Display Utilizing Macro Discharge Cell Structure with Long Electrodes Gap)

  • 김민태;허준;김윤기;김동현;이해준;이호준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1314-1318
    • /
    • 2012
  • Recently, applications of plasma display to the large public display and transparent display gain much attention. With this background, we report characteristics of opposite electrodes discharge cell with long electrode gap in comparison with conventional co-planar surface discharge. The cell size of test panel is $2950{\mu}m{\times}840{\mu}m$, which corresponds to that of the display having diagonal size of 130" with XGA resolution. Electrode gap of co-planar and opposite electrode structure are $240{\mu}m$ and $500{\mu}m$ respectively. These gap dimensions provide similar driving voltage windows. Experimental results show that opposite discharge provides approximately four fold higher luminous efficacy compared with that of the surface discharge. Resulting efficacy is found to be higher than 19 lm/W in green phosphor with 10 KHz continuous pulse operation.

완화전류 측정에 의한 지중배전케이블의 열화진단 (Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment)

  • 김주용;송일근;김동명;윤태상;정상봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

One-Cycle Control Strategy for Dual-Converter Three-Phase PWM Rectifier under Unbalanced Grid Voltage Conditions

  • Xu, You;Zhang, Qingjie;Deng, Kai
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.268-277
    • /
    • 2015
  • In this paper, a dual-converter three-phase pulse width modulation (PWM) rectifier based on unbalanced one-cycle control (OCC) strategy is proposed. The proposed rectifier is used to eliminate the second harmonic waves of DC voltage and distortion of line currents under unbalanced input grid voltage conditions. The dual-converter PWM rectifier employs two converters, which are called positive-sequence converter and negative-sequence converter. The unbalanced OCC system compensates feedback currents of positive-sequence converter via grid negative-sequence voltages, as well as compensates feedback currents of negative-sequence converter via grid positive-sequence voltages. The AC currents of positive- and negative-sequence converter are controlled to be symmetrical. Thus, the workload of every switching device of converter is balanced. Only one conventional PI controller is adopted to achieve invariant power control. Then, the parameter tuning is simplified, and the extraction for positive- and negative-sequence currents is not needed anymore. The effectiveness and the viability of the control strategy are demonstrated through detailed experimental verification.

Interleaved ZVS DC/DC Converter with Balanced Input Capacitor Voltages for High-voltage Applications

  • Lin, Bor-Ren;Chiang, Huann-Keng;Wang, Shang-Lun
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.661-670
    • /
    • 2014
  • A new DC/DC converter with zero voltage switching is proposed for applications with high input voltage and high load current. The proposed converter has two circuit modules that share load current and power rating. Interleaved pulse-width modulation (PWM) is adopted to generate switch control signals. Thus, ripple currents are reduced at the input and output sides. For high-voltage applications, each circuit module includes two half-bridge legs that are connected in series to reduce switch voltage rating to $V_{in}/2$. These legs are controlled with the use of asymmetric PWM. To reduce the current rating of rectifier diodes and share load current for high-load-current applications, two center-tapped rectifiers are adopted in each circuit module. The primary windings of two transformers are connected in series at the high voltage side to balance output inductor currents. Two series capacitors are adopted at the AC terminals of the two half-bridge legs to balance the two input capacitor voltages. The resonant behavior of the inductance and capacitance at the transition interval enable MOSFETs to be switched on under zero voltage switching. The circuit configuration, system characteristics, and design are discussed in detail. Experiments based on a laboratory prototype are conducted to verify the effectiveness of the proposed converter.

소형 풍력발전용 영구자석형 동기발전기의 센서리스 제어 (Sensorless Control of PMSG for Small Wind Turbines)

  • 장석호;박홍극;이동춘;김흥근
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2009
  • 본 논문은 소형 풍력발전용 영구자석형 동기발전기에서 고정자 자속과 역기전력을 이용한 센서리스 제어방법을 제안한다. 기존의 다이오드와 DC-부스트 컨버터를 사용한 소형 풍력발전용 컨버터와는 달리 2-Leg 3상 PWM 컨버터를 사용하여 발전기를 구동한다. 이는 기존의 컨버터와 비교하여 가격적으로 뒤지지 않으며, 발전기의 벡터제어가 가능하여 최대출력 제어시 발전 효율향상을 확인할 수 있다. 그리고 센서리스 제어 알고리즘을 적용하여 속도 측정을 위해 사용되는 엔코더를 제거하므로 시스템의 가격을 저감시킨다. 제안된 알고리즘은 PSIM 시뮬레이션을 사용하여 컨버터 제어 성능과 발전기의 최대 출력 제어의 타당성을 검증한다.

단상 부스트 PFC 컨버터용 가상 DQ 동기좌표계 기반 고성능 전류제어 알고리즘 (High Performance Current Control Algorithm Based on Virtual DQ Synchronous Reference Frame for Single-Phase Boost PFC Converter)

  • 김현근;진성민;이상희;이수형;김준석
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.496-503
    • /
    • 2017
  • This study proposes a high-performance current control algorithm for a diode-bridge-type single-phase boost power factor correction (PFC) converter. The conventional asynchronous single-phase current controllers that directly control AC-type current tend to be accompanied by steady-state errors due to their poor dynamic characteristics for the transient-state, which can be attributed to bandwidth limitations and phase delays. In the proposed algorithm, an ideal current control with minimal phase delays and steady-state errors can be achieved by using a virtual DQ synchronous reference frame and by controlling the synchronous reference frame excluding the frequency component in the single-phase system. The performance of the conventional asynchronous single-phase current controller is compared with that of the proposed algorithm through simulation and experiments, and the results have confirmed the superiority of the latter.

강유전체 충진 선대선 방전갭의 코로나 방전 및 오존 발생특성 (Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Gap with a Ferroelectric Pellet Bed)

  • 신정민;배창환;안창진;이종훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1873-1875
    • /
    • 2003
  • Surface corona discharge characteristics of a ac corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charged stored on the surfaces of the ferroelectric pellets by a at corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between wire electrodes. As a result, in the case of the corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be generated efficiently. It is also found that, the ferroelectric pellet barrier discharge reactor had better discharge characteristics for plasma generation than the wire-to-wire discharge reactor without pellets.

  • PDF

DSP 기반 HD급 비디오/오디오 디코더 시스템 개발 (Development of a DSP based Decoder for High-definition Video/Audio System)

  • 박영근;김봉주;김병일;김정근;장태규;이전우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2681-2683
    • /
    • 2003
  • 본 논문에서는 HDTV(High Definition TV) 방송수신을 위한 DSP기반의 HD급 비디오/오디오 디코더 시스템을 개발하고 그 성능을 확인하였다. DSP 플랫폼은 TI사의 TMS320C6415를 대상으로 하였으며 TI의 DSP RTOS인 DSP/BIOS를 이용하여 방송스트림인 TS (Transport Stream)을 분리하기 위한 TS Demuxer, MPEC-2 비디오 디코더 및 AC-3 오디오 디코더 알고리즘을 통합하였으며, 각각의 알고리즘은 대상 DSP 플랫폼인 TMS320C64x에 맞게 고정소수점 구조화 및 최적화를 실시하였다. 테스트를 위한 시스템은 스트리밍을 위한 호스트 PC와 PCI버스를 통해 연결된 DSP보드로 구성하였으며 실제 HDTV방송용 스트림과 SD급 스트림을 이용하여 성능을 확인하였다.

  • PDF

교류 자기장 표준장치 개발 및 국제비교 결과 분석 (Development of AC magnetic field standard system and analysis of the international key comparison)

  • 박포규;김영균;김완섭;김문석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.3-5
    • /
    • 2009
  • 교류 자기장의 정밀측정, 자기장 측정기의교정 및 관련 시험 등 을 지원하기 위해 교류자기장 표준장치를 개발하였다. 주파수에 따른 확장분확도(expanded uncertainty, 2 $\sigma$)는 1 MBz 이하에서 0.16 %, 1 kHz $\sim$ 5 kHz 에서 0.26 %, 5 kHz $\sim$ 20 kHz에서 0.44 % 이었다. 측정결과에 대한 국제적 신뢰성 및 상호인증을 확보하기 위하여 핵심측정표준 국제비교(international key comparison)에 참여하였으며, 또한 측정능력, 교정 및 시험방법 등에 대한 국제적 전문가로부터 평가(peer review)를 수감하였다. 따라서 한국표준과학연구원 (KRISS)에서 교정 및 측정한 결과에 대해서는 국제적 상호인증을 받을 수 있다.

  • PDF