• 제목/요약/키워드: AC Synchronous Motor

검색결과 112건 처리시간 0.025초

AC 서보모터 제어 프로그램 구조 설계 및 구현 (Structure Design and Implementation of AC Servo Motor Control Program)

  • 김경아;최준영
    • 대한임베디드공학회논문지
    • /
    • 제18권5호
    • /
    • pp.209-215
    • /
    • 2023
  • This study proposes an AC servo motor control program structure and its implementation method to efficiently integrate 13 types of additional compensation algorithms into the basic FOC (field-oriented control) algorithm program. Various compensation algorithms are necessary to enhance the stability and performance of machine tools by compensating for interference from disturbances and vibrations. Each compensation algorithm is implemented as a separate, independent function and called from a switch-case statement in the ISR (interrupt service routine) of the PWM (pulse-width modulation) device. The advantages of this approach include facilitating not only debugging and testing but also reducing the possibility of errors during the program development phase. Thus, it is easy to add and activate each specific compensation algorithm for the program update during the program operation phase. The implemented motor control program was experimented with a single-axis feed shaft testbed driven by a commercial AC servo motor control drive board and a 750 Watts SPMSM (surface-mounted permanent magnet synchronous motor), and the results verified its normal operation and performance improvement.

AC-DC Zeta Converter for Power Quality Improvement in Direct Torque Controlled PMSM Drive

  • Singh Bhim;Singh B.P.;Dwivedi Sanjeet
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.146-162
    • /
    • 2006
  • This paper deals with the analysis, design and implementation of an AC-DC Zeta converter in discontinuous current mode (DCM) of operation used for power quality improvement at AC mains in direct torque controlled (DTC) permanent magnet synchronous motor (PMSM) drives. The designed Zeta converter feeds a direct torque controlled PMSM drive system. Modeling and simulation is carried out in a standard PSIM software environment. Test results are obtained on the developed prototype Zeta converter using DSP ADMC401. The results obtained demonstrate the effectiveness of the Zeta converter in improving power quality at AC mains in the PMSM drive system.

이중여자 유도전동기의 해석 (Analysis of Doubly-Excited Induction Motor)

  • 강만원;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1095-1097
    • /
    • 1993
  • The double excited induction motor has two sets of three-phase system : One is connected to the ac source to take care of energy convertion, and the other is to the inverter controlable frequency and/or magnitude of voltage, both of the induction mode and the synchronous mode are possible in double excitation motor, and the proposed double excitation motor can be driven as a synchronous motor by the extra three-phase input. At the synchronous mode the efficiency is improved so higher than that at induction mode or induction motor. The rating of the inverter used for speed control can be reduced upto one-fifth of that for conventional induction motor. Also the cost and maintenance fee of double excitation induction motor can be reduced compared to any other motors.

  • PDF

전류제어 알고리즘에 의한 동기모터의 속도제어 (Speed Control for Synchronous Motor Using the Current Control Algorithm)

  • 변정환;정석권
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.67-73
    • /
    • 1999
  • It is not easy to control the speed of AC motors accurately without modeling with some parameters for the controlled system. However, there are some application parts which do not require high speed responses strictly and the motor parameters can not to be identified simply. In this paper, a speed control method for a synchronous motor(S.M) with unknown parameters of the motor is investigated. The method is based on the current control algorithm. Speed controller and current controller are designed using PI control law. Some experiments are performed using DSP and power expert system to prove the validity of the proposed method. Throughout experimental results, the method is confirmed successfully. This method is expected to control the system with unknown parameters of the S.M efficiently.

  • PDF

New Mathematical Models with Core Loss Factor for Control of AC Motors

  • Shinnaka, Shinji
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.630-635
    • /
    • 1998
  • This paper establishes in a new unified manner new mathematical models with core(iron) loss factor for two kinds of AC motors, induction and synchronous motors which are supposed to generate torque precisely or/and efficiently under vector controls. Our new models consist of three basic equations consistent with the others such as differential equation describing electromagnetic dynamics, torque equation describing torque generating mechanism, energy transmission equation describing how injected energy is wasted, saved or transmitted where all vector signals are defined in general frame of arbitrary instant angular velocity. It is clearly shown in our models that equivalent core-loss resistance can express appropriately and separately both eddy-current and hysteresis losses rather than mere vague loss. Proposed model of induction motor is the most compact in sense of the number of employed interior states and parameters. This compact model can also represent eddy-current and hysteresis losses of rotor as well as stator. For synchronous motor, saliency is taken into consideration. As well known model for cylindrical motor can be obtained directly from salient one as its special case.

  • PDF

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.

A Study on the Torque Angle Compensator Design of an IPM Type PM Synchronous Motor

  • Byun, Young-Chul;Jeon, Hyuck-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.139.1-139
    • /
    • 2001
  • Nowadays due to the remarkable advance of power electronics and micro controller, a Brushless AC servomotor which has the characteristics of the high inertia to torque ratio, the high power density, the maintenance free, and so on is being used widely in industrial robots, machine tools, and factory automation. In a conventional DC motor, the polarity commutation is performed of itself by mechanical brush and commutator, but the PM synchronous motor requires an electrical commutation according to the rotor position. Then for the maximum torque production PM synchronous motor has to be equipped with a controller which maintains the optimal phase angle between the stator field and the magnetic field ...

  • PDF

양수발전소 동기전동기의 기동제어 알고리즘에 관한 연구 (A study developing control algorithm for Pumped-Storage Synchronous motor drive)

  • 강승우;박신현;김장목;임익헌;류호선;김진성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.467-471
    • /
    • 2003
  • The large synchronous motor for the pumped-storage plant(or SFC : Static Frequency Converter) has to be brought up to 100$\%$ rated speed and synchronized with the AC power network. Starting the motor from rest is achieved by switching current into the stator winding so that interaction between this stator current and the rotor flux will cause the correct direction of torque to be developed so that the motor turns in the required direction. Starting ranges of the synchronous motor are divided into three regions. The first region Is at standstill, the second that is called by the forced commutation is from standstill to 5-8$\%$ of rated speed, and the third, which is called by the natural commutation, is from 5-8$\%$ of rated speed to 100$\%$ rated speed. So this paper describes three regions of the control techniques of the pumped-storage synchronous motor drive.

  • PDF

듀얼 서보모터 구동형 프레스 시스템의 동기화 제어기법 연구 (A Study on Synchronization Control Technique of Dual-Servo Press System)

  • 나상건;권오신;강재훈;허훈
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.206-215
    • /
    • 2013
  • In this paper, a synchronization control technique of dual-servo motor driven press system is proposed. An independent cascade PID control technique has been applied to the conventional press system for advancement of control stability. However, it is not easy to reduce synchronous error using the independent cascade PID control technique when some different load disturbances are involved in each motor. The eccentric error of the slide caused by the problem degrade the control performance of the BDC(Bottom Dead Center). In order to achieve reduction of the synchronous error between two servo motors and accurate position control simultaneously, a new control scheme comprised with cascade PID control loop and cross-coupling loop is proposed. In simulation using Matlab SIMULINK, the AC servo system is designed. The control performance of proposed technique is compared with conventional control technique to the model of AC servo system. Also, the sub-scale model of dual-servo motor driven press system which can replicate the slide motion is constructed for experimental verification for the performance of the proposed control technique. The cross-coupling control technique reveals more precise and stable performances in the position and synchronization controls.

Simulink 기반 자동차용 모터 고성능 제어를 위한 자동코드 생성에 관한 연구 (A Study on Auto Code Generation for High Performance Motor Control using the Simulink)

  • 이근호;함승권
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1125-1131
    • /
    • 2013
  • Nowadays, embedded software development using the MATLAB/Simulink system is gradually emerging. Studies generating the parts of embedded S/W in a Rapid Prototype are presented. In this paper, a method to generate the entire embedded S/W of enhanced AC motor control is proposed. High performance motor control could not be achieved with the basic Simulink library and RAppID Toolbox library as it does not have PWM based Interrupt, an ASAC (Analog Sensing for AC Motors) function and other special functions of the Freescale MPC555x. Consequently, the required libraries for enhanced AC motor control are created by Legacy code tool, TLC (Target Language Compiler) and S-Function (System-Function) of MATLAB/ Simulink and utilized in the Rapid Prototype. Motor control performance and execution time are compared automatically to the generated-code S/W with the hand coded S/W. The IPMSM (Interior Permanent Magnet Synchronous Motor) and MPC5553 board that were designed as the AC motor controller for hybrid electrical vehicle are used for the test. The performances meet the requirements and satisfactory results are acquired.