• Title/Summary/Keyword: AC Power Source

Search Result 524, Processing Time 0.029 seconds

A Digitally Controlled Three-Phase Cycloconverter Type High Frequency AC Link Inverter Using Space Vector Modulation

  • Sha, Deshang;Qin, Zian;Wu, Dan;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • In this paper, a three phase cycloconverter type high frequency AC link inverter is discussed. The configuration consists of a high frequency full-bridge inverter and a high frequency transformer followed by a three phase cycloconverter whose switch is composed of anti-series connected MOSFETs with a common source. A simple digital control strategy based on space vector modulation (SVM) and repetitive control for the cycloconverter is proposed although its input voltage is a high frequency AC pulse. The operation principle of the proposed control strategy is analyzed and the equivalent working modes during one interval are also presented. The effectiveness of the proposed control strategy is verified through Matlab/Simulink simulations and experiments on a 1.45kW prototype.

A High Frequency Link Direct DC-AC Converter for Fuel Cell Power Source (연료전지 발전 시스템용 고주파 링크 DC-AC 컨버터)

  • Song, Y.J.;Park, S.I.;Jeong, H.G.;Han, S.B.;Jung, B.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.245-249
    • /
    • 2005
  • This paper describes a boost converter cascaded high frequency link direct dc-ac converter suitable for fuel cell power sources. A new multi-loop control for a boost converter to reduce the low frequency input current harmonics drawn from fuel cell is proposed. A new PWM technique for the cycloconverter at the secondary to reject the low order harmonics in the output voltages is presented in detail.

  • PDF

Fundamental Output Voltage Enhancement of Half-Bridge Voltage Source Inverter with Low DC-link Capacitance

  • Elserougi, Ahmed;Massoud, Ahmed;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.116-128
    • /
    • 2018
  • Conventionally, in order to reduce the ac components of the dc-link capacitors of the two-level Half-Bridge Voltage Source Inverter (HB-VSI), high dc-link capacitances are required. This necessitates the employment of short-lifetime and bulky electrolytic capacitors. In this paper, an analysis for the performance of low dc-link capacitances-based HB-VSI is presented to elucidate its ability to generate an enhanced fundamental output voltage magnitude without increasing the voltage rating of the involved switches. This feature is constrained by the load displacement factor. The introduced enhancement is due to the ac components of the capacitors' voltages. The presented approach can be employed for multi-phase systems through using multi single-phase HB-VSI(s). Mathematical analysis of the proposed approach is presented in this paper. To ensure a successful operation of the proposed approach, a closed loop current controller is examined. An expression for the critical dc-link capacitance, which is the lowest dc-link capacitance that can be employed for unipolar capacitors' voltages, is derived. Finally, simulation and experimental results are presented to validate the proposed claims.

Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter (전압 이득이 향상된 단상 전류형 qZ-소스 인버터)

  • Shin, Hyun-Hak;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

Performance improvement of a voltage source active filter (병렬형 전압원 능동필터의 성능개선)

  • Kang, Yu-Ri;Kim, Won-Ho;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.553-555
    • /
    • 1994
  • Various nonlinear loads such as diode rectifiers, and phase controlled converters connected to at source cause harmonic pollutions in ac mains. Recently some filters have been proposed to minimize the potential problems. This study describes a method to improve the performances of a voltage source active filter. Two feedback loops are used in the scheme : one for reactive power compensation and the other for harmonic eliminations.

  • PDF

Characteristics of Transient State and Stress of Three-Phase Switched Trans Z-Source DC/AC Power Converter (3상 Switched Trans Z-소스 직류/교류 전력변환기의 스트레스 및 과도상태 특성)

  • Lim, Young-Cheol;Kim, Se-Jin;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 2012
  • When typical Z-source DC/AC inverter(ZSI) is operated in high voltage gain area, because of its high duty ratio, voltage and current stress in Z-network of typical ZSI are increased. This paper proposes a new switched trans ZSI(STZSI) with two switched trans cells which consist of one trans and two diodes. To confirm the operation performance of the proposed system, the PSIM simulation is performed for typical ZSI, switched inductor ZSI and the proposed STZSI. Voltage / current stress and transient state characteristics of each method are compared under the condition of DC input voltage 100[V] and output phase voltage 66[Vrms]. As a result, we confirmed that transient state of the proposed STZSI is short compared with the conventional ZSI because the high voltage gain is obtained using the same duty ratio, also a low duty ratio is required for the same output voltage. Finally, we could know the proposed system have low voltage and current stress in Z-network compared with the conventional ZSI.

High power factor Buck-Boost converter with partial resonant circuit (부분공진형 고역률 승강압 컨버터)

  • Seo, Gi-Yeong;Gwon, Sun-Geol;Lee, Hyeon-U;Gwak, Dong-Geol;Bae, Seong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.126-128
    • /
    • 1993
  • Rectifiers of power conversion system are widely used condenser at input to be cheap and to be simple construction. But this method is produced harmonics of pulse at peak value of input AC voltage. The main circuit which make input current of a sinusoidal wave and improve power-factor is almost taken step-up converter. This paper is able to obtain high power-factor and efficiency because the input current is made sinusoidal wave in single phase alternating current(AC) source. Also the proposed converter is able to minimize switching loss by ZVCS(zero voltage switching and zero current switching).

  • PDF

Supercapacitor of Auxiliary Electric Power Source in Industrial Safety for High Output (고출력용 산업안전 보조전원의 Supercapacitor)

  • 허진우;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.335-343
    • /
    • 2003
  • In the electrode fabrication of unit cell, it was ascertained that electrochemical characteristics were greatly increased with 90 wt.% of BP-20, 5 wt.% of Super P and 5 wt.% of mixed binder [P(VdF-co-HFP) : PVP =7 : 3] The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. The electrochemical characteristics of 2.3 V/3,000 F grade EDLC were as follows: 0.35 m of DC-ESR (100 A discharge), 0.14 mof AC-ESR (AC amplitude 100 mV), 2.80 Wh/kg (3.73 Wh/L) of energy density and 4.64 kW /kg (6.19 kW/L) of power density. Power output was compatible with electric vehicle applications, uninterrupted power supply and engine starter, in due consideration of Ragone relations.

  • PDF

A cooperative control study of Jeju ±80kV 60MW HVDC for voltage stability enhancement (제주 ±80kV 60MW HVDC 협조 제어 방안 연구)

  • Yoon, Jong-Su;Seo, Bo-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1221-1225
    • /
    • 2012
  • This paper describes CSC(Current Sourced Converters)-based HVDC operational strategy for voltage stability enhancement in the power system. In case of CSC-based HVDC system, rectifier and inverter consume reactive power up to about 60% of converter rating. Therefore, CSC-based HVDC is basically not useful system for voltage stability even if AC filters and shunt capacitors are attached. But, If the particular power system condition is fulfilled, CSC-based HVDC also can be the rapid reactive power source for voltage stability enhancement using a cooperative control with converter and AC filters/Shunt Capacitors. In this paper, the cooperative control algorithm is presented and simulated to ${\pm}80kV$ 60MW HVDC system in Jeju island.

Harmonic reductions of three-phase phase-controlled converter (3상 컨버터의 Passive Filter와 Notch에 의한 저고조파 저감)

  • Hong, S.T.;Bae, Y.H.;Kim, E.S.;Rim, G.H.;Lee, H.W.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.856-859
    • /
    • 1993
  • Line-current harmonics resulting from AC to DC power conversion interfere with power system operation and reduce power factor, hence resulting in increasing power source unnecessarily. This paper investigates the harmonic reduction methods of a three-phase phase-controlled converter on AC and DC sides using passive filters and notches.

  • PDF