• 제목/요약/키워드: AC Power

검색결과 3,405건 처리시간 0.033초

단상 배전 STATCOM을 이용한 전기철도시스템의 전압강하 및 전력품질 향상 (Compensation of voltage drop and improvement of power quality at AC railroad system with single-phase distributed STATCOM)

  • 김준상;김진오;이준경;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.192-193
    • /
    • 2006
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion may also occur to AC electrical railroad system. These problems affect not only power system stability. but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, and then, it is analyzed voltage drop and power quality for AC electrical railroad system both with single-Phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

  • PDF

전류 제어 루프에 보상을 행하지 않는 능동 역률 제어 AC/DC 컴버터의 제어기 설계 (Design of active power factor control AC/DC converter having current control loop with no compensator)

  • 이인호;김성환;유지윤;박귀태
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.216-223
    • /
    • 1996
  • The active power factor control AC/DC converter needs a current loop compensator to obtain better dynamic characteristics and power factor performance, but the optimal design of a current loop compensator is difficult because the AC/DC converter is a nonlinear system having periodically varying poles and zeros. The predictive current control scheme generates a control input using the dynamic equations of the AC/DC converter so that the dynamic of the AC/DC converter is included in the controller and the necessary bandwidth and the gain characteristics of the current control loop are satisfied. And as a result, a compensator becomes unnecessary and the current loop shows the improved current loop characteristics. In this paper, a power factor controller without current loop compensator by adopting a predictive current control scheme is designed and the designed power factor controller is modelled by using a small signal perturbation modelling technique, and simulated to investigate its small signal characteristics. A 200 W power factor control AC/DC converter is built to verify the effectiveness of the proposed power factor controller.

  • PDF

1.9-GHz CMOS Power Amplifier using Adaptive Biasing Technique at AC Ground

  • Kang, Inseong;Yoo, Jinho;Park, Changkun
    • Journal of information and communication convergence engineering
    • /
    • 제17권4호
    • /
    • pp.285-289
    • /
    • 2019
  • A 1.9-GHz linear CMOS power amplifier is presented. An adaptive bias circuit (ABC) that utilizes an AC ground to detect the power level of the input signal is proposed to enhance the linearity and efficiency of the power amplifier. The ABC utilizes the second harmonic component as the input to mitigate the distortion of the fundamental signal. The input power level of the ABC was detected at the AC ground located at the VDD node of the power amplifier. The output of the ABC was fed into the inputs of the power stage. The input signal distortion was mitigated by detecting the input power level at the AC ground. The power amplifier was designed using a 180 nm RFCMOS process to evaluate the feasibility of the application of the proposed ABC in the power amplifier. The measured output power and power-added efficiency were improved by 1.7 dB and 2.9%, respectively.

PWM Cuk AC-AC 컨버터를 위한 새로운 Commutation 회로 (A New Commutation Circuit for PMW Cuk AC-AC Converter)

  • 최남섭;김인동;이옥룡;노의철
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.431-439
    • /
    • 2006
  • 본 논문에서는 PMW Cuk AC-AC 컨버터를 위한 새로운 commutation 회로를 제안한다. 제안된 commutation 회로는 컨버터 전류의 commutation을 위하여 개선된 Undeland 스너버를 이용한다. 개선된 스너버 회로는 주 스위치의 전압/전류 스트레스 저감, 효율 개선과 같은 장점을 갖는다. 본 논문에서는 실험을 통하여 제안된 commutation 회로의 효과와 적용 가능성을 확인하였다.

Model Predictive Control of Bidirectional AC-DC Converter for Energy Storage System

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.165-175
    • /
    • 2015
  • Energy storage system has been widely applied in power distribution sectors as well as in renewable energy sources to ensure uninterruptible power supply. This paper presents a model predictive algorithm to control a bidirectional AC-DC converter, which is used in an energy storage system for power transferring between the three-phase AC voltage supply and energy storage devices. This model predictive control (MPC) algorithm utilizes the discrete behavior of the converter and predicts the future variables of the system by defining cost functions for all possible switching states. Subsequently, the switching state that corresponds to the minimum cost function is selected for the next sampling period for firing the switches of the AC-DC converter. The proposed model predictive control scheme of the AC-DC converter allows bidirectional power flow with instantaneous mode change capability and fast dynamic response. The performance of the MPC controlled bidirectional AC-DC converter is simulated with MATLAB/Simulink(R) and further verified with 3.0kW experimental prototypes. Both the simulation and experimental results show that, the AC-DC converter is operated with unity power factor, acceptable THD (3.3% during rectifier mode and 3.5% during inverter mode) level of AC current and very low DC voltage ripple. Moreover, an efficiency comparison is performed between the proposed MPC and conventional VOC-based PWM controller of the bidirectional AC-DC converter which ensures the effectiveness of MPC controller.

직류링크 전해커패시터 없는 AC-DC-AC 컨버터 재어에 관한 연구 (New Control Seheme for AC-DC-AC Converters without DC Link Electrolytic Capacitor)

  • 김준석;설승기
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.397-408
    • /
    • 1994
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with a unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $\mu$F ceramic capacitor in the DC link. By controlling the active kpower balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitors regardless of the load variation even in the unbalanced source condition.

  • PDF

고전력밀도 AC/DC Adapter를 위한 off-time 제어법 (Off-time Control Method for High Power Density AC/DC Adapter)

  • 강신호;장준호;홍성수;이준영
    • 전력전자학회논문지
    • /
    • 제12권6호
    • /
    • pp.510-516
    • /
    • 2007
  • 본 논문에서는 더 높은 에너지 효율을 요구하는 전자 기기들의 사용에 따른 고전력 밀도 AC/DC adapter를 위한 향상된 제어 방법을 제안한다. PFC (Power Factor Correction) 토폴로지는 BCM (Boundary Conduction Mode)제어 방식을 적용한 부스트 토폴로지를 기본으로 하였으며, DC/DC 토폴로지는 50% 고정 duty법과 함께 새롭게 제안된 Off-time 제어법을 적용한 하프브릿지 토폴로지를 기본으로 하였다. 이는 반도체 소자와 마그네틱 소자의 크기를 줄이는데 용이하다. 85W급 AC/DC 어뎁터(18.5V/4.6A)를 설계하여 실험한 결과 90%의 효율과 $36W/in^3$의 전력밀도가 측정되었고 무부하시 전력 손실은 0.5W를 달성하였다.

고전력밀도 AC/DC 어댑터의 설계 (Design of High Power Density AC/DC Adapter)

  • 이준영
    • 전력전자학회논문지
    • /
    • 제15권4호
    • /
    • pp.259-265
    • /
    • 2010
  • 본 논문에서는 더 높은 에너지 효율을 요구하는 전자 기기들의 사용에 따른 고전력 밀도 AC/DC 어댑터의 구조를 제안한다. PFC (Power Factor Corrector) topology는 BCM (Boundary Conduction Mode)제어 방식을 적용한 Boost topology를 기본으로 하였으며, DC/DC topology는 주파수제어를 적용한 LLC 공진 컨버터를기본으로 하였다. 이는 반도체 소자 및 마그네틱 소자의 크기를 줄이는데 용이하다. 85W급 AC/DC adapter (18.5V/4.6A)를 설계하여 실험한 결과 $90V_{rms}$의 입력전압에서 90%의 효율과 $36W/in^3$의 전력밀도가 측정되었고 무부하시 전력 손실은 0.5W를 달성하였다.

Single Phase Utility Frequency AC-High Frequency AC Matrix Converter Using One-Chip Reverse Blocking IGBTs based Bidirectional Switches

  • Hisayuki, Sugimura;Kwon, Soon-Kurl;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.125-128
    • /
    • 2006
  • This paper presents a novel type soft switching PWM power frequency AC-AC converter using bidirectional active switches or single phase utility frequency AC-high frequency AC matrix converter. This converter can directly convert utility frequency AC (UFAC, 50Hz/60Hz) power to high frequency AC (HFAC) power ranging more than 20kHz up to 100kHz. A novel soft switching PWM prototype of high frequency multi-resonant PWM controlled UFAC-HFAC matrix converter using antiparallel one-chip reverse blocking IGBTs manufactured by IXYS corp. is based on the soft switching resonance with asymmetrical duty cycle PWM strategy. This single phase UFAC-HFAC matrix converter has some remarkable features as electrolytic capacitor DC busline linkless topology, unity power factor correction and sine-wave line current shaping, simple configuration with minimum circuit components, high efficiency and downsizing. This series load resonant UFAC-HFAC matrix converter, incorporating bidirectional active power switches is developed and implemented for high efficiency consumer induction heated food cooking appliances in home uses and business-uses. Its operating performances as soft switching operating ranges and high frequency effective power regulation characteristics are illustrated and discussed on the basis of simulation and experimental results.

  • PDF

수용가 전원 응용을 위한 단상 Buck AC-AC 전력 변환기 (A Single-Phase Buck AC-AC Power Converter for Custom Power Applications)

  • 강정식;최남섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.427-430
    • /
    • 2001
  • 산업분야에서 많이 사용되고 있는 컴퓨터나 자동화 제조공정 등은 순간적인 전압저하나 이상전압에 매우 민감하게 반응한다. 부하에 공급되는 전력의 신뢰도의 문제가 증가함에 따라 수용가 측에서는 무정전 전원장치(UPS)와 같은 일정전압을 유지한 수 있는 전력 조절장치들을 사용하고 있다. 본 논문에서는 수용가 전원의 안정화를 위한 제어장치로서 단상 Buck AC-AC 전지변환기를 제안한다. 제안된 전력변환기는 IGBT스위칭 모듈을 사용하고 전압의 저하가 발생했을 때 펄스폭 변조(PWM) 제어에 의하여 일정한 전압을 유지할 수 있다. 본 논문에서는 정상상태에서의 동작특성을 해석하고 PSPICE 시뮬레이션으로 동작특성을 확인한다.

  • PDF