• Title/Summary/Keyword: AC Plasma

Search Result 533, Processing Time 0.034 seconds

Effects of a Butanol Fraction of Alisma canaliculatum and of Selenium on Blood Glucose Levels and Lipid Metabolism in Streptozotocin-Induced Diabetic Rats

  • Kim, Myung-Wha
    • Nutritional Sciences
    • /
    • v.6 no.2
    • /
    • pp.85-93
    • /
    • 2003
  • The purpose of this study was to investigate the effects of a butanol fraction of fraction of Alisma canaliculatum All. Braun et Bouche (Ac), and of selenium (Se), on plasma gllucose and lipid levee in streptozotocin (STD-induced diabetic rats. Male Sprague-Dawley rats, fed the AIN-93 recommended diet, were divided into five groups: a non-diabetic control group (no STZ treatment), and four 572-induced diabetic groups which consisted of a diabetic-control group, an Ac-treated group, an Ac-Se treated group, and a Se-treated group. Diabetes was induced in the rats by an injection of STZ into the tail vein at a dose of 45 mg/kg body weight. The butanol (BuOH) fraction of Ac was orally administered at a rate of 400 mg/kg body weight for 21 days to both the Ac and Ac-Se groups. The supplementation of selenium in the Se and Ac-Se groups was achieved by adding (freshly, every day) 2 mg of Se as Na$_2$SeO$_3$ per kg of feed. The rats'body weights and hematocrit (Hct) levels were measured, along with plasma levels of glucose, insulin, cholesterol, HDL-cholesterol, triglyceride (TG), and free fatty acids (FFA). Aminotransferase activities were also analyzed. The non-diabetic rats gained weight, while the diabetic rats lost weight - except in the Ac-Se group, which maintained their initial weight. The blood glucose levels of the Ac group and the Se group were significantly lower than for the diabetic-control group. The plasma triglyceride levels were lowered when both Ac and Se were administered to diabetic rats. The concentrations of plasma FFA in the Ac-Se group were significantly lower compared with the diabetic-control group. Plasma cholesterol levels and alanine aminotransferase activity in the Ac, Ac-Se, and Se groups were significantly lower when compared with the diabetic-control group. Aspartate aminotransferase activity was significantly lower in the Se group compared to the other diabetic groups. These data show that treatment with a butanol fraction of Ac in combination with Se has no synergistic effect. Plasma glucose levels tended to be low when Se was administered to diabetic rats. Supplementation of Se in diabetic rats did not elicit a significant increase in plasma insulin levels or result in hypolipemic effects.

A Magnetic Microsensor based on the Hall Effect in an AC Microplasma (극미세 교류 플라즈마 내에서의 홀 효과를 이용한 마이크로 자기센서)

  • Seo, Young-Ho;Han, Ki-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1266-1272
    • /
    • 2003
  • This paper presents a new class of magnetic microsensors based on the Hall effect in AC microplasma. In the theoretical study, we develop a simple model of the plasma Hall sensor and express the plasma Hall voltage as a function of magnetic field, plasma discharge field, pressure, and electrode geometry. On this basis, we have designed and fabricated magnetic microsensors using AC neon plasma. In the experiment, we have measured the Hall voltage output of the plasma microsensors for varying five different conditions, including the frequency and the magnitude of magnetic field, the frequency and the magnitude of plasma discharge voltage, and the neon pressure. The fabricated magnetic microsensors show a magnetic field sensitivity of 8.87${\pm}$0.18㎷/G with 4.48% nonlinearity.

AC Plasma Power Supply with Variable Voltage and Variable Frequency (가변전압 가변주파수(VVVF) 교류 플라즈마 전원장치)

  • Shin Wan-Ho;Yun Kee-Pok;Jeoung Hwan-Myoung;Choi Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1205-1207
    • /
    • 2004
  • AC plasma power supply is used to control a ozone generator and a air pollution gas. AC plasma power supply is composed of power semiconductor switch devices and control board adapted SHE(Selected Harmonic Elimination) PWM method. AC plasma power supply with sinusoidal VVVF(variable voltage and variable frequency) is realized. Its output voltage range is from 0 [V] to 20[kV] and output frequency range is from 8[kHz] to 20[kHz]. Using proposed system, AC high voltage and high frequency discharge is tested in the DBD(dieletric barrier discharge) reactor, and the space distribution of a its non-thermal plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

The characteristics of AC-PDPs According to binary and ternary gas mixtures of He-Ne-Xe_

  • Lee, H.J.;Son, C.G.;Lee, S.B.;Han, Y.K.;Jeoung, S.H.;You, N.L.;Lim, J.E.;Lee, J.H.;Moon, M.W.;Oh, P.Y.;Jeoung, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1195-1198
    • /
    • 2005
  • The improvement of efficiency is the one of the most important part in AC PDPs . To achieve high efficiency, high VUV emission efficiency and High ion induces secondary electron emission coefficient are needed. We have measured the emission spectra of vacuum ultraviolet rays and ion induced secondary electron emission coefficient of MgO protective layer in surface discharge AC-PDP with binary and ternary gas mixtures. We have investigated electro-optical characteristics of AC-PDPs to optimum gas mixture for high efficient.

  • PDF

Effect of CHCl$_3$fraction of Alisma canaliculatum with selenium on the plasma glucose and lipids levels in streptozotocin-induced diabetic rats (택사 CHCl$_3$분획물과 Selenium 보충이 당뇨 흰쥐의 혈당과 지질함량에 미치는 영향)

  • 김명화
    • Korean journal of food and cookery science
    • /
    • v.18 no.3
    • /
    • pp.300-308
    • /
    • 2002
  • The purpose of this study was to investigate the effect of chloroform(CHC1$_3$) fraction of Alisma canaliculatum All. Braun et Bouche(Ac) with selenium(Se) on the plasma glucose and lipid levels in streptozotocin(STZ)-induced diabetic rats. Male Sprague-Dawley rats were divided into five groups. The normal and diabetic rats were separated into four groups: the STZ-control group, the Ac group, the Ac-Se group and the Se group. Diabetes was induced in the male rats by an injection of STZ into the tail vein at a dose of 45 mg/kg. The CHCl$_3$fraction of Ac(250 mg/kg) was administered orally for 14 days. The supplementation was achieved with the AIN-93 recommended diet by adding 2 mg/kg diet of selenium as Na$_2$SeO$_3$. which was prepared freshly everyday. The body weight, hematocrit(Hct), glucose, insulin, cholesterol, HDL-cholesterol, triglyceride(TG) and free fatty acids(FFA) concentrations in plasma were measured. The aminotransferase activities were also analyzed. The changes of body weight in the experimental groups were not significantly different from that of the STZ-control group, but diabetes hyperphagia accompanied changes with body weight loss in Ac-Se group. The levels of Plasma cholesterol were not significantly different among the experimental groups. The concentrations of FFA in the Ac-Se group increased significantly compared with the STZ-control group. The effect of Se alone significantly increased aspartate aminotransferase activity and alanine aminotransferase activity. The results showed that the treatment of CHCl$_3$fraction of Ac in combination with Se has no synergistic effect. There was a tendency for the plasma glucose levels to decrease when Se was administered into diabetic rats. Supplementation of Se in diabetic rats did not elicit a significant increase in plasma insulin levels and exhibited hypotriglyceridemic effect.

Experimental Study on Reduction of Temporal Dark Image Sticking on Bright Screen in AC-PDPs Using RF-Plasma Treatment on MgO layer

  • Park, Choon-Sang;Kim, Jae-Hyun;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.101-103
    • /
    • 2009
  • Minimizing the residual impurity level on the MgO layer is the key factor for reducing temporal dark image sticking on bright screen. In this paper, to reduce the residual impurity level on the MgO layer of 50-in. full-HD ac-PDP with He (35%) - Xe (11%) contents, RF-plasma treatments on the MgO layer are adopted under various gases for plasma treatment. As a result of monitoring the difference in the display luminance between the before and after 5-min. sustain discharge with a square-type image at peak luminance, the Ar and Ar>$O_2$ plasma treatments can reduce the temporal dark image sticking on the bright screen in an ac-PDP.

  • PDF

A study of characteristics for Image sticking in AC - Plasma Display Panel

  • Han, Yong-gyu;Lee, S.B.;Jeong, S.H.;Son, C.G.;Yoo, N.L.;Lee, H.J.;Lim, J.E.;Lee, J.H.;Jeoung, J.M.;Ko, B.D.;Oh, P.Y.;Moon, M.W.;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.263-265
    • /
    • 2005
  • In the alternative current plasma display panel(AC-PDP) technology, it is very important to remove the image sticking for improving an image quality. In this paper, we have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. We have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. The preventing method of image sticking was proposed by adopting the Sticking Remove Pulse(SRP). The variation of brightness is most affected by the MgO to be formed at the surface of the phosphor layer. As a result, the image sticking is reduced when the driving method adopted an SRP.

  • PDF

Basic Performance Test of a Three Phase AC Arc Plasma Torch System for Plasma Gas Reforming (플라즈마 가스 개질 응용을 위한 3상 아크 플라즈마 토치 시스템 특성 실험)

  • DONG-HYUN LEE;DARIAN FIGUERA-MICHAL;HAE-WON PARK;NAM-KI LEE;SANG-YUN PAEK;SHIYOUNG YANG;JUN-HO SEO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.1
    • /
    • pp.8-16
    • /
    • 2023
  • In this work, we report basic performance test results of a lab-scale three phase alternative current (AC) arc plasma torch system for plasma gas reforming applications. The suggested system primarily consists of three graphite electrodes inclined at 12.5° to the central axis, a 𝞥 150 mm cylindrical gas path and a three phase-60 Hz AC power supply. At air flow rate of 50 Lpm and arc currents of 100-175 A, test results revealed that plasma resistances were decreasing from 1.08 Ω to 0.53 Ω with the increase of plasma power from 9.3 kW to 13.8 kW, causing the decrease of power factor and increase of the line voltages. However, the injected air can be heated quickly up to the temperatures of >1,200℃ when injecting AC arc plasma powers of >10 kW.

Influence of constraint MgO deposition onto phosphors on luminance properties in AC Plasma Display Panels

  • Jeoung, Jin-Man;OH, P.Y.;Moon, M.W.;Lee, J.H.;Jeong, J.E.;Lee, H.J.;Han, Y.K.;Lee, S.B.;Jeong, S.H.;Yoo, C.K.;Yoo, N.R.;Choi, E.H.;Ko, B.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1215-1217
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is the image sticking. In this research, we have investigated the PDP cell with constraint deposition MgO on phosphor, the electrical and optical properties in the PDP cell were examined. Also, we have investigated the correlation with image sticking and degraded MgO protective layer, phosphor in AC-PDP. As a result, we measured the secondary electron emission coefficient ${\gamma}$, discharge characteristics and Brightness for the constraint degraded phosphor are compared with those of nondegraded phosphor.

  • PDF

Secondary Electron Emission Characteristics of Functional Layer in AC-PDP

  • Son, Chang-Gil;Han, Young-Gyu;Kim, Yong-Hee;Cho, Byeong-Seong;Hong, Young-Jun;Song, Ki-Baek;Bae, Young-Joo;Kim, In-Tae;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.736-739
    • /
    • 2009
  • We have studied that the secondary electron emission characteristics of functional layers which have different kinds of MgO sub-micrometer size powder in AC-PDP. We used cathodoluminescence(CL) and gamma focused ion beam (${\gamma}$-FIB) system for measurement of secondary electron emission characteristics. Also we made 6 inch test panel which applied functional layers for evaluation of discharge characteristics.

  • PDF