• 제목/요약/키워드: AC/DC conversion

검색결과 244건 처리시간 0.027초

Load Dispatching Control of Multiple-Parallel-Converters Rectifier to Maximize Conversion Efficiency

  • Orihara, Dai;Saitoh, Hiroumi;Higuchi, Yuji;Babasaki, Tadatoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1132-1136
    • /
    • 2014
  • In the context of increasing electric energy consumption in a data center, energy efficiency improvement is strongly emphasized. In a data center, electric energy is largely consumed by DC power supply system, which is based on a rectifier composed by multiple parallel converters. Therefore, rectifier efficiency must be improved for minimizing loss of DC power supply system. Rectifier efficiency can be modulated by load allocation to converters because converter efficiency depends on input AC power. In this paper, we propose a new control method to maximize rectifier efficiency. The method can control load allocation to converters by introducing active power converter control scheme and start-and-stop of converters. In order to illustrate optimal load allocations in a rectifier, a maximization problem of rectifier efficiency is formulated as a nonlinear optimization one. The problem is solved by Lagrangian relaxation method and the computation results provide the validity of proposed method.

Finite State Model-based Predictive Current Control with Two-step Horizon for Four-leg NPC Converters

  • Yaramasu, Venkata;Rivera, Marco;Narimani, Mehdi;Wu, Bin;Rodriguez, Jose
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1178-1188
    • /
    • 2014
  • This study proposes a finite-state model predictive controller to regulate the load current and balance the DC-link capacitor voltages of a four-leg neutral-point-clamped converter. The discrete-time model of the converter, DC-link, inductive filter, and load is used to predict the future behavior of the load currents and the DC-link capacitor voltages for all possible switching states. The switching state that minimizes the cost function is selected and directly applied to the converter. The cost function is defined to minimize the error between the predicted load currents and their references, as well as to balance the DC-link capacitor voltages. Moreover, the current regulation performance is improved by using a two-step prediction horizon. The feasibility of the proposed predictive control scheme for different references and loads is verified through real-time implementation on the basis of dSPACEDS1103.

다회로 LVDC 전력망 안정화를 위한 운영 알고리즘 실증 (Demonstration of Operating Algorithm for Stabilizing Multi-LVDC Power Grid)

  • 이유경;박병우;김춘성;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_3호
    • /
    • pp.1259-1267
    • /
    • 2023
  • In recent years, as the demand for distributed power has increased, the need for microgrids connected to grid power and renewable power generation sources has emerged. In the case of DC microgrids, reactive power does not occur, and power conversion losses are reduced compared to AC when connecting to the load and power grid[2]. With the revitalization of the DC distribution network industry, various studies and demonstrations of DC microgrids have been carried out. In the case of the recent unit distribution, its stability and effectiveness have been verified through empirical and research analysis. However, there is a lack of empirical tests to prevent chain accidents for the protection of the power grid circuits and the misoperation of the distributed power system caused by individual accidents when connecting various distributed power sources and power grids. In this paper, the operation plan of a stable multi-circuit DC distribution connection for the demonstration site was verified through the protection cooperation and operation algorithm for the stable linkage management of the DC distribution network composed of such a multi-circuit.

A NOVEL ZVS-CV PWM AC-DC CONVERTER

  • Yan, Baiping;Chen, Zhiming;Liu, Jian
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.709-712
    • /
    • 1998
  • A new ZVS-CV PWM converter with power factor correction (PFC) function is presented in this paper. The new topology is a integration of a boost converter and a ZVS-CV topology in a single power conversion stage. The new converter can be regulated in pulse-width modulation (PWM) by universal integrated control circuits. Some design considerations are given in detail. A laboratory prototype has been implemented to show the feasibility of the approach and the analysis.

  • PDF

인버터의 손실저감을 위한 소프트 스위칭기법 (A Soft switching method for Loss reduction of Inverter)

  • 곽동걸;김영철;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

차량용 현가장치 적용 에너지 하베스팅을 위한 전력변환 시스템에 관한 연구 (A study on Power Conversion System for Energy Harvesting applied to Vehicle Suspension)

  • 이진규;안민혁;박병건
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.210-211
    • /
    • 2017
  • 본 논문에서는 자동차가 주행 시 노면에서 발생되는 충격을 흡수하는 현가장치에서 전기에너지를 얻기 위한 에너지 하베스팅 기술에 적용 가능한 전력변환 시스템에 관하여 연구 하였다. 제안된 전력변환장치는 2상 AC-DC 다이오드를 직렬로 구성하여 선형 발전기의 서로 다른 주파수와 크기를 갖는 출력전압에 대해 효과적으로 전기에너지로 변환하도록 하였다. 제안한 전력변환시스템의 가능성을 확인하기 위해 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

축전지 충전기용 전압형 컨버터 (Voltage Source Converter for battery charging)

  • 곽주식;김제홍;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.265-267
    • /
    • 1995
  • A voltage source PWM converter with battery charging and AC/DC power conversion ability is proposed in this paper. The proposed voltage source PWM converter is independently controlled by active and reactive components and implemented by DSP controller. In UPS application the mathematical model of the voltage source PWM converter has been derived. Finally, the performance of the voltage source converter is shown and discussed through experimental results.

  • PDF

도시철도 직류급전용 더블컨버터의 출력특성 향상을 위한 모드 변환 시 점호각 제어 연구 (A Study on the Firing Angle at the Mode Conversion to Improve the Output Characteristics of the Double Converter for Urban Railway DC Power Supply)

  • 서승삼;한성우;변기식
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.533-542
    • /
    • 2015
  • 본 논문은 도시철도 전동차 정차 시에 발생하는 회생전력으로 인해 전차선 가선전압 상승 시에 Converter(Forward)에서 Inverter(Reverse)로 mode 변환하여 상승된 가선전압을 AC 모선으로 환류하여 전차선 전압을 일정하게 유지하고 전동차 정차 시에 발생하는 회생전력을 재사용할 수 있는 부산도시철도의 더블 컨버터 직류 변전설비를 제안하며 전차선 직류전압 품질향상을 위해 부산도시철도 더블 컨버터 직류 변전설비에서 발생하는 Converter/Inverter mode 변환 시의 undershoot와 overshoot를 최소화할 수 있는 최적의 사이리스터 점호각을 시뮬레이션을 통하여 제시하였다.

무효전력 보상을 포함하는 새로운 회전형 변압기 계통 연계 시스템 (New VFT Grid-Connection System Including Reactive Power Compensation)

  • 오정식;박태식;김성환;곽노홍;박장현
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.143-150
    • /
    • 2019
  • Back-to Back HVDC 방식을 사용한 비동기 계통연계 기술은 고조파 발생, 높은 비용 및 낮은 확장성의 문제를 가지고 있으며, 이러한 문제를 해결하기 위하여 회전형 변압기를 이용한 비동기 계통 연계 기술에 대한 연구가 활발히 진행되고 있다. 그러나 회전형 변압기의 인덕턴스 성분으로 인한 무효전력이 발생되고 별도의 무효전력 보상설비의 추가 설치에 대한 문제가 필연적으로 발생된다. 따라서 본 논문에서는 회전형 변압기를 사용한 비동기 계통 연계 시스템의 필수요소인 정류용 AC-DC 컨버터를 유효전력 공급뿐만 아니라 무효전력을 보상할 수 있도록 설계함으로서 기존의 회전형 변압기의 무효전력 보상 문제를 해결하고자 하며, 제안된 방식은 시뮬레이션을 통해 성능을 검증하였다.

더블라인 주파수 제거를 위한 양방향 컨버터의 전력 디커플링 제어 (Power Decoupling Control of the Bidirectional Converter to Eliminate the Double Line Frequency Ripple)

  • Amin, Saghir;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.62-64
    • /
    • 2018
  • In two-stage single-phase inverters, inherent double line frequency component is present at both input and output of the front-end converter. Generally large electrolytic capacitors are required to eliminate the ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability. However, the ripple can hardly be eliminated without the hardware combined with an energy storage device or a certain control algorithm. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC/AC power conversion system. The proposed control algorithm is composed of two loop, ripple rejection loop and average voltage control loop and no extra hardware is required. In addition, it does not require any information from the phase-locked-loop (PLL) of the inverter and hence it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented, and experimental results are presented.

  • PDF