• 제목/요약/키워드: AC/A ratio

검색결과 490건 처리시간 0.027초

직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성 (Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages)

  • 이복희;양순만
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.

파밤나방 세포주에서 Autographa californica 핵다각체병 바이러스의 감염 특성 (Characteristics of Autographa californica Nuclear Polyhedrosis Virus in Spodoptera exigua Cell Line.)

  • 최재영;우수동;홍혜경;강석권
    • 한국미생물·생명공학회지
    • /
    • 제26권2호
    • /
    • pp.161-166
    • /
    • 1998
  • AcNPV에 대해 감수성을 보이는 파밤나방 세포주인 Se301 세포주의 AcNPV를 이용한 발현 벡터계에서의 유용성을 알아보기 위하여 Se301세포주에서 AcNPV의 감염 특성을 Sf-21 세포주에서와 비교하였다. 그 결과, 바이러스의 감염상은 두 세포주에서 거의 유사하였으나 감염 7일 후에 세포로부터 방출된 다각체의 비율은 Se301 세포주에서 훨씬 높았다. 또한 전체 다각체 생성율은 Se301 세포주에서 약간 높았지만 그 차이는 매우 근소하여 대체적으로 두 세포주에서 거의 비슷하였으나 생성된 다각체의 크기는 Se301세포주에서 더욱 컸다. 한편, 세포주나 바이러스의 증식율과는 무관하게 AcNPV에 의한 다각체 단백질의 발현량이 Se301 세포주에서 약 2.4배 높게 나타남으로써 Se301 세포주가 AcNPV를 이용한 발현 벡터계에서 숙주 세포로서 매우 유용하게 이용될 수 있음을 보여 주었다.

  • PDF

고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor)

  • 김종해;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

음곡(陰谷)(KI10)에 시술한 오가피(五加皮) 약침(藥鍼)이 난소적출 생쥐의 골다공증(骨多孔症)에 미치는 영향 (Effects of the Herbal-Acupuncture with Acanthopanacis cortex extract at KI10 (Eumgok) on osteoporosis in ovariectomized DDY mice)

  • 임윤경;정연탁
    • Korean Journal of Acupuncture
    • /
    • 제25권1호
    • /
    • pp.165-196
    • /
    • 2008
  • Objective : The purpose of this study is to observe the effects of herbal-acupuncture with Acanthopanacis cortex extract (AC-HA) at KI10 (Eumgok) on osteoporosis in ovariectomized (OVX) ddy mice. Methods : We carried out several experimental items to analyze the changes in body weight, uterine weight, uterus index, tibial length, the ash bone weight, tibial BMD, serum ALP, serum creatinine, serum osteocalcin, serum Ca, and the levels of Ca, P, Ca/P ratio in tibia, and we performed histological and histomorphological analysis as well. Results : Tibial BMD was significantly decreased by OVX, while significantly increased by AC-HA at KI10. Serum creatinine level was significantly increased by OVX, while significantly decreased by AC-HA at KI10. Serum osteocalcin level was significantly increased by OVX, while significantly decreased by AC-HA at KI10. Tibial TBV(trabecular bone volume) was significantly decreased by OVX, while significantly increased by AC-HA at KI10. AC-HA at KI10 significantly suppressed the OVX-induced increase of GPL(growth plate length) of tibia in mice. Conclusion : These results suggest that AC-HA at KI10 has a therapeutic effect on osteoporosis in OVX mice.

  • PDF

Effects of the Impurity Gases on the Characteristics of ac PDP

  • Shin, Joong-Hong;Park, Chung-Hoo
    • 한국전기전자재료학회논문지
    • /
    • 제15권10호
    • /
    • pp.909-913
    • /
    • 2002
  • The luminance and discharge characteristics of ac PDP may be significantly affected by a small amount of impurity gas in working gas. These impurity gases such as O$_2$, O, C and H$_2$ can be mixed in the manufacturing and /or discharge process. In this paper a small amount of impurity gas in acPDP are introduced quantitatively and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with increase in the partial pressure of impurity gases, especially in H$_2$, O$_2$ and CO$_2$. Under the condition of the impurity gas ratio of 2${\times}$10$\^$-3/ for Ar, N2, H$_2$, CO$_2$ and O$_2$, the luminous efficiency decreased about 8%, 8%, 32%, 36% and 50%, respectively.

하이브리드 슈퍼커패시터의 음극 및 양극 설계에 따른 전기화학적 거동 (Electrochemical Behavior Depending on Designed-Anode and Cathodes of Hybrid Supercapacitors)

  • 신승일;이병관;하민우;안건형
    • 한국재료학회지
    • /
    • 제29권12호
    • /
    • pp.774-780
    • /
    • 2019
  • The performance of Li-ion hybrid supercapacitors (asymmetric-type) depends on many factors such as the capacity ratio, material properties, cell designs and operating conditions. Among these, in consideration of balanced electrochemical reactions, the capacity ratio of the negative (anode) to positive (cathode) electrode is one of the most important factors to design the Li-ion hybrid supercapacitors for high energy storing performance. We assemble Li-ion hybrid supercapacitors using activated carbon (AC) as anode material, lithium manganese oxide as cathode material, and organic electrolyte (1 mol L-1 LiPF6 in acetonitrile). At this point, the thickness of the anode electrode is controlled at 160, 200, and 240 ㎛. Also, thickness of cathode electrode is fixed at 60 ㎛. Then, the effect of negative and positive electrode ratio on the electrochemical performance of AC/LiMn2O4 Li-ion hybrid supercapacitors is investigated, especially in the terms of capacity and cyclability at high current density. In this study, we demonstrate the relationship of capacity ratio between anode and cathode electrode, and the excellent electrochemical performance of AC/LiMn2O4 Li-ion hybrid supercapacitors. The remarkable capability of these materials proves that manipulation of the capacity ratio is a promising technology for high-performance Li-ion hybrid supercapacitors.

침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성 (A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA)

  • 이재필;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

화학폐수슬러지와 무연탄을 이용한 복합건조공정의 조사시간에 따른 고형연료의 특성 평가 (Characteristic Evaluation of RDF for the Combined Drying Produced by Weight Mixing Ratio Use Chemical Wastewater Sludge and Anthracite Coal)

  • 이승철;정진희;이준희
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.417-424
    • /
    • 2016
  • The objective of this study was to evaluate the microwave drying characteristics of mixtures of chemical wastewater sludge (70~90%) and anthracite coal (10~30%) with respect to physical and economic factors such as mass, volume reduction, moisture content, drying rate and heating value when the wastes were dried at different weight mixing ratio and for different microwave irradiation time. The drying process were carried out in a microwave oven, the combined drying process with a 2,450 MHz frequency and 1 kW of power. Maximum dry rates per unit area on the microwave drying of mixtures with chemical wastewater sludge and anthracite coal were $35.5kg\;H_2O/m^2{\cdot}hr$ for Cs90-Ac10; $40.1kg\;H_2O/m^2{\cdot}hr$ for Cs80-Ac20 and $35.0kg\;H_2O/m^2{\cdot}hr$ for Cs70-Ac30. The result clearly indicated that moisture can be effectively and inexpensively removed from the wastes through use of the microwave drying process.

제어전극을 갖는 쌍극성 하전장치의 입자응집 특성 (Particle Agglomeration of a Bipolar Charging System with a Control Grid)

  • 문재덕;안창진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가 (A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents)

  • 황성민;김기웅;강찬석;이성주;이용호
    • Progress in Superconductivity
    • /
    • 제13권2호
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.