• Title/Summary/Keyword: A-contraction

Search Result 2,563, Processing Time 0.034 seconds

The Effects of the Contraction Degree of Hip Joint Adductor on Abdominal Muscle Activity during Bilateral Lower Extremity Raising

  • Kim, Min-Kyu;Cho, Yong-Ho;Park, Ji-Won;Choi, Jin-Ho;Ko, Yu-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.217-220
    • /
    • 2016
  • Purpose: This study was to investigate the differences abdominal muscles activities of according to hip adductor contraction levels 20% (mild), 50% (moderate), and 70% (strong) of MVIC on during bilateral lower extremity raising exercise on supine. Methods: The subjects of the study were a total of 39 persons including 23 healthy males and 16 females, who performed bilateral lower extremity raising exercise in 20%, 50%, 70% MVIC hip contraction. Muscle activities were measured by using S-EMG in RA (rectus abdominis), IO (internal oblique), and EO (external oblique). Results: Muscle activity of the internal oblique abdominal muscle and external oblique abdominal muscle, their activities were also greatest with the adductor contraction size at 70% and there was statistically significant difference when compared with the adductor contraction size at 20% and 50% (p<0.05). As for the rectus abdominis muscle according to the size of contraction of the adductor was greatest at 70%, without statistically significant difference (p>0.05). Conclusion: bilateral lower extremity raising with strong hip joint adductor contraction was effective exercise to strengthen abdominal muscles. If subjects could not perform strong hip adductor contraction, moderate contraction is effective abdominal muscle contraction exercise. The contraction size of the adductor is small, weak contraction may trigger middle level contraction and therefore appropriate application of the exercise program of bilateral leg raising may result in great effect as a lumbar stabilization exercise.

SOME RESULTS ON BEST PROXIMITY POINT FOR CYCLIC B-CONTRACTION AND S-WEAKLY CYCLIC B-CONTRACTION MAPPINGS

  • V. Anbukkarasi ;R. Theivaraman;M. Marudai ;P. S. Srinivasan
    • The Pure and Applied Mathematics
    • /
    • v.30 no.4
    • /
    • pp.417-427
    • /
    • 2023
  • The purpose of this paper is establish the existence of proximity point for the cyclic B-contraction mapping on metric spaces and uniformly convex Banach spaces. Also, we prove the common proximity point for the S-weakly cyclic B-contraction mapping. In addition, a few examples are provided to demonstrate our findings.

The mechanism of sphingosine-1-phosphate induced contraction in cat esophageal smooth muscle cells.

  • Choi, Tae-Sik;Lee, Tai-Sang;Woo, Jae-Gwang;Kim, Yong-Sung;Sohn, Uy-Dong
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.77.3-78
    • /
    • 2003
  • We previously shown that sphingosylphosphorylcholine, a lysophosphatidic acid, produced contraction in isolated single cells of cat ilium. We investigated the mechanism of sphingosine-1-phosphate (S1P)-induced contraction of circular smooth muscle cells in cat esophagus. S1P produced esophageal contraction in a dose dependent manner. The maximal contraction (l0$\^$-7/ M) induced at 1min. Pertusis toxin (PTX) inhibited contraction induced by S1P, suggesting that the contraction is mediated to a PTX-sensitive G-protein. (omitted)

  • PDF

The Influence of an Abdominal Draw-In Maneuver and Pelvic Floor Muscle Contraction on Lateral Abdominal Muscle Contraction Thickness in Subject with and without Low Back Pain (요통 환자와 정상인에 적용한 골반저근 수축과 복부 드로우-인이 외측 복부 근육 수축 두께에 미치는 영향)

  • Youn, Hye-Jin;Kim, Ji-Seon;Yang, Jin-Mo;Ki, Kyong-Il
    • PNF and Movement
    • /
    • v.13 no.1
    • /
    • pp.25-30
    • /
    • 2015
  • Purpose: The aim of this study was to examine the effects of abdominal muscle contraction thickness using real-time ultrasound imaging while applying an abdominal draw-in maneuver (ADIM) and pelvic floor muscle contraction (PFC) to low back pain patients and healthy subjects. Methods: The subjects were 21 young adults; a group of 10 low back pain patients and a control group of 11 healthy subjects. Measurements were made with the subjects on a pillow in a supine position, with the knee joints flexed at 60 degrees. While the two groups conducted ADIM and PFC, their transverse abdominal muscle (TrA), internal abdominal oblique muscle (IO), and external abdominal oblique muscle (EO) thicknesses were measured using an ultrasound imaging system. Result: The TrA muscle contraction thickness ratio during PFC and ADIM was significantly lower in the low back pain group than in the healthy group (p<0.05). The EO muscle contraction thickness ratio during ADIM was also significantly lower in the low back pain group than in the healthy group. The healthy group's muscle contraction thickness ratio was significantly lower during PFC than during ADIM in the TrA, IO, and EO (p<0.05). The low back pain group's muscle contraction thickness ratio was lower during PFC than during ADIM in the TrA, IO, and EO, but the difference was not statistically significant. Conclusion: The results of this study indicate that oral direction during ADIM induced an appropriate contraction of the TrA. Therefore, the procedure reported here may be applied during rehabilitation for appropriate contraction of the TrA.

A Study on High Contraction Conditions by the CPB Process of the Nylon Fabric (Nylon 박지의 CPB방식에 의한 고수축 조건에 관한 연구)

  • Bin, Soyoung;Kim, Dong Kwon;Baek, Yongjin;Jin, Sungwoo;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.27 no.4
    • /
    • pp.309-317
    • /
    • 2015
  • This study is the high contraction processing conditions set by the method of the CPB process. And the ultimate goal of this study is the high contraction of the CPB processing test method that can solve the problems of the high-contraction fabric processing method of the current jet dyeing machine. Non-coating process(CPB process) developed by the expression of a soft touch, light weight, functional and to develop excellent breathable nylon fabric. The nylon fabrics established the optimum processing conditions through the high contraction of the various test conditions, the CPB system.(The benzyl alcohol was used as the main constrictor.) At this time, the warp and weft contraction of nylon fabric was about 20%. And it established the constrictor concentration, the treatment temperature, time of a variety of tests. Also non-coating process(CPB process) can develop soft touch, lightweight, excellent air permeability. As a result, we developed a high contraction nylon fabric having a uniform surface. Manufactured fabric is used for Wind-proof and Down-proof.

Effect of Noradrenaline and Endothelium on the High $K^+$ or Ach-induced Contraction in the Pig Myocardial Coronary Artery (돼지 심근내 관상동맥의 고$K^+$ 및 아세틸콜린 수축에 미치는 노아드레날린과 내피세포의 작용 `)

  • Jang, Dong-Cheol;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.637-646
    • /
    • 1991
  • Effect of noradrenaline and endothelium on the high K+ or Ach-induced contraction were investigated in the pig myocardial coronary artery. The helical strip of isolated pig myocardial coronary artery was immersed in the Tris-buffered Tyrode`s solution equilibrated with 100% O2 at 37oC and its isometric tension was measured. High K+ and Ach-induced contraction were dose-dependent. By denuding the endothelium, dose-contraction curve of K+ was not shifted significantly to the left and upward, but that of Ach was shifted significantly to same direction 25 mM K+ - and Ach-induced contraction were relaxed by norepinephrine[NE]. NE-induced relaxation was blocked by the pretreatment of propranolol, which was known as b-adrenoceptor blocker. And, phenylephrine known as a-adrenoceptor agonist, and clonidine known as a-adrenoceptor agonist increased the 25mM K+ - induced contraction respectively. Denuding of endothelium did not show any significant effects on NE-induced relaxation and contraction increased by phenylephrine and clonidine. Tyramine increased 25mM K+ - induced contraction further. The contractile response by tyramine on the 25mM K+ - induced contraction was not blocked by the pretreatment of phentolamine, but was partially blocked by the pretreatment of atropine. From the above results, it is suggested that activation of a1-and a2-adrenoceptors induce the contraction, activation of b-adrenoceptors induce the relaxation, and NE-induced relaxation is mainly due to activation of b-adrenoceptors. Also it is suggested that denudation of endothelium did not influence NE-induced relaxation, but influence Ach-induced contraction in the pig myocardial coronary artery.

  • PDF

COMMON FIXED POINT THEOREMS IN THE SETTING OF EXTENDED QUASI b-METRIC SPACES UNDER EXTENDED A-CONTRACTION MAPPINGS

  • Amina-Zahra Rezazgui;Wasfi Shatanawi;Abdalla Ahmad Tallafha
    • Nonlinear Functional Analysis and Applications
    • /
    • v.28 no.1
    • /
    • pp.251-263
    • /
    • 2023
  • In the setting of extended quasi b-metric spaces, we introduce a new concept called "extended A-contraction". We then use our concept to prove a common fixed point result for a pair of self mappings under a set of conditions. Also, we provide the concepts of extended B-contraction and extended R-contraction. We then establish a common fixed point under these new contractions. Our results generalize many existing result of fixed point in metric spaces. Furthermore, we give an example to illustrate and support our result.

Numerical Analysis on the Internal Flow Field Characteristics of Wind Tunnel According to Contraction Type (수축부 형상에 따른 풍동 내부유동장 특성에 대한 수치해석)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.5-12
    • /
    • 2017
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to investigate the internal flow fields characteristics according to wind tunnel contraction type. The turbulence model used in this study is a realizable $k-{\varepsilon}$ modified from the standard $k-{\varepsilon}$ model. As a results, the distribution of the axial mean velocity components along the central axis of the flow model is very similar to the ASME and BE types, and the cubic and cosine types. When the flow passes through the interior space of the analytical models, the flow resistance at the inlet of the plenum chamber is the largest at BS type contraction, but the smallest at cubic type contraction. The boundary layer thickness is the smallest in the cosine type contraction as the axial distance increases. The maximum turbulent kinetic energy in the test section is the smallest in the order of the contraction of cubic type and cosine type. Comprehensively, cubic type contraction is the best choice for wind tunnel performance, and cosine type contraction can be the next best solution.

A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES (광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구)

  • Chung, Yeon-Chung;Min, Kyung-San;Lee, Hae-Hyoung;Cho, Kyung-Mo;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).