• Title/Summary/Keyword: A-POC

Search Result 146, Processing Time 0.029 seconds

One-pot Synthesis of Cinnamylamines with Various Protecting Groups from Cinnamyl Ethers

  • Jung, Young-Hoon;Kim, Ji-Duck
    • Archives of Pharmacal Research
    • /
    • v.24 no.5
    • /
    • pp.371-376
    • /
    • 2001
  • The reaction of various alkyl cinnamyl ethers with CSI afforded the corresponding cinnamylamines with various protecting groups, such as -NHMoc, -NHiPoc, -NHCbz, -NHPnz, -NHTroc and -NHAloc. In the case of cinnamyl t-butyl ether and cinnamyl p-methoxybenzyl ether, the corresponding cinnamyl carbamates were formed via a different reaction pathway from the above.

  • PDF

Partial Discharge Characteristics on Protrusion Defects in SF6-N2 Mixture Gases (SF6-N2 혼합가스 중 돌출 결함의 부분방전 특성)

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Park, Kyoung-Soo;Kil, and Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2016
  • Studies on a $SF_6$-mixture and -alternative gas has been in progress to reduce the use of $SF_6$ gas as an insulation material of GIS (gas insulated switchgears). In this paper, we dealt with PD (partial discharge) characteristics in pure $SF_6$ and $N_2$, and their mixtures on aspects of insulation design and risk assessment for GIS. A POC (protrusion on conductor) and a POE (protrusion on enclosure) as the major defects were fabricated to simulate PD. We analyzed the DIV (discharge inception voltage), DEV (discharge extinction voltage), pulse magnitude, counts and phase distribution of PD pulse in $SF_6-N_2$ mixtures ($SF_6$ 100%, $SF_6$ 80%-$N_2$ 20%, $SF_6$ 50%-$N_2$ 50%, $SF_6$ 20%-$N_2$ 80%, and $N_2$ 100%) according to the IEC60270. The DIV, DEV as well as magnitude of PD pulse decreased on the POC as increase of $N_2$ ratio. For the POE, the DIV and DEV in $N_2$ ratio below 50% were the same voltages as those in $SF_6$ 100%. In this experiment, $SF_6$ 80%-$N_2$ 20% mixture could be considered with the equivalent insulation performance to a GIS.

Characteristics of Organic Carbon and Apparent Oxygen Utilization in the NE Pacific KODOS Area (북동태평양 KODOS 해역의 유기탄소 및 겉보기산소량 특성)

  • Son, Ju-Won;Son, Seung-Kyu;Kim, Kyeong-Hong;Kim, Ki-Hyune;Park, Yong-Chul;Kim, Dong-Hwa;Kim, Tae-Ha
    • Ocean and Polar Research
    • /
    • v.27 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • The samples for organic carbon analysis were collected between $5^{\circ}\;and\;17^{\circ}N$ along $131.5^{\circ}W$ in the northeast Pacific KODOS (Korea Deep Ocean Study) area. The mean concentration of total organic carbon (TOC) in the surface mixed layer $({\sim}50 m)$ was $100.13{\pm}2.05{\mu}M-C$, while the mean concentration of TOC in the lower 500m of the water column was $50.19{\pm}4.23{\mu}M-C$. A strong linear regression between TOC and temperature $(r^2=0.70)$ showed that TOC distribution was controlled by physical process. Results from the linear regression between chlorophyll-a and TOC, and between chlorophyll-a and particulate organic carbon (POC), decreasing of dissolved organic carbon (DOC) in the surface layer caused by non-biological photo-oxidation process. Below the surface layer, biological production and consumption occurred. DOC accumulation dominated in the depth range of $30{\sim}50m$ and DOC consumption occurred in the depth range of $50{\sim}200m$. TOC was inversely correlated with apparent oxygen utilization (AOU) and TOC/AOU molar ratios ranged from -0.077 to -0.21. These ratios indicated that TOC oxidation was responsible fur $10.9{\sim}30.1%$ (mean 20.2%) of oxygen consumption in the NE Pacific KODOS area. In the euphotic zone, distributions of dissolved and particulate organic matter were controlled by photo-chemical, chemical, biological and physical processes.

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Implementation Plan of Integrated Medical Information System for Ubiquitous Healthcare Service (U-Healthcare 서비스를 위한 통합의료정보시스템의 구축방안)

  • Jung, Yong-Sik
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.115-126
    • /
    • 2010
  • Modern society can be described as ubiquitous computing over the concept of information. Information technology(IT) has been developing in a way that relative technologies are integrated to each other. Especially in ubiquitous environment, medical information industry shows significant interest in the U-healthcare service area. This paper will first look into U-healthcare service environment and component of Integrated Medical Information Systems(IMIS). Secondly, it examines the basic technological factors for integrated medical information systems, which is datawarehouse, network, communication standards and technology related U-healthcare service. Finally it proposes how to implement and operate new integrated medical information system for ubiquitous health care service. The system will do point of care(POC) for customers by real time and diagnose them using their various and personal medical data. The information will be communicated back to the customers, which will improve their satisfaction.

The Relationship between the Fractionation Characteristics and Decomposition Rate of Organic Carbon in Nam River and Geumho River (남강 및 금호강에서 유기탄소 존재형태와 분해속도와의 관계)

  • Ho-Sub Kim;Seok-Gyu Kim;Seung-Young Oh
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.2
    • /
    • pp.131-141
    • /
    • 2023
  • In this study, the relationship between organic carbon distribution characteristics and decomposition rate classified according to the particle size and biological degradation characteristics in water was investigated for the Nam river and Geumho river. The average concentrations of TOC in the Nam river and Geumho river were 2.7±1.2 mg/L and 5.0±1.2 mg/L, respectively, but the composition ratios for each type of organic carbon were similar. An average value of 80.9% of TOC was present as DOC and 72.8% of DOC consisted of Refractory-DOC (RDOC). In addition, the change in the RDOC composition ratio according to temporal and spatial distribution was the smallest. There was no difference in the decomposition rate of organic carbon except for TOC by the site (p≥0.108, one-way ANOVA), and the decomposition rates of Labile-POC (LPOC) and LDOC were similar at 0.139±0.102 and 0.137±0.149 day-1, respectively (p=0.110, paired t-test). The coefficient of variation (CV) of the decomposition rate of DOC (average 8.1%), which had the smallest composition ratio of organic carbon, was 1.1, showing the largest temporal variation. The TOC, POC, and DOC decomposition rates showed a significant correlation with the ratio of the initial concentration to the concentration after 25 days of decomposition (OC25/OC0) (r2=0.89~0.94, p<0.001), and the decomposition rates of LPOC and LDOC were significantly correlated with the ratio of the initial concentration to the concentration after 5 days of decomposition (LOC5/LOC0) (r2=0.67~0.75). This suggests that it is possible to estimate the decomposition rate through the concentration of each type of organic carbon.

Spatio-temporal Distributions of Organic Matter in Surface Sediment in the Central Part of the South Sea, Korea (남해 중부해역 표층퇴적물 유기물의 시.공간 분포특성)

  • Noh, Il-Hyeon;Yoon, Yang-Ho;Park, Jong-Sick;Soh, Ho-Young;Kim, Dae-Il
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.203-215
    • /
    • 2006
  • Field observations on the spatio-temporal distribution of organic matter of the surface sediment were carried out at 15 stations in the central parts of the South Sea of Korea from April 2002 to January 2003. The range of water temperature and salinity in bottom waters, mud content and water content of surface sediment were $8.06{\sim}23.35^{\circ}C,\;29.20{\sim}34.51\;psu,\;71.2{\sim}99.9%$ and $38.7{\sim}68.9%$, respectively. Measured parameters on the surface sediments of ignition loss (IL), chemical oxygen demand (CODs), phaeopigment, particulate organic carbon (POC) and particulate organic nitrogen (PON) also ranged in $3.9{\sim}l2.5%,\;9.60{\sim}44.05\;mgO_2/g-dry,\;1.58{\sim}29.51\;{\mu}g/g-dry,\;3.12{\sim}13.01\;mgC/g-dry$ and $0.49{\sim}2.00\;mgN/g-dry$, respectively. The spatio-temporal distribution of organic matter demonstrated higher concentrations offshore than at lesions near the coastal line. Higher concentrations occurred in the summer and spring. The results indicated that the origin of organic matter in surface sediments in the central part of the South Sea was autochthonous rather than allocthonous because the organic matter had an average C/N ratio of 6.44 (${\pm}0.51$). However, the composition of autochthonous organic matter was mainly derived from detritus rather than living phytoplankton, which was Indicated by the results of the POC/phaeopigment ratio. A principal component analysis (PCA) indicated that 73.2% of the variability in the data was described by two factors: 1) an 'environmental factor concerning the accumulation of materials (57.3%)' and 2) 'origin of organic matter and the composition by primary production (15.9%)'. The sedimentary environment in the central part of the South Sea was divided into four regions from the factor score of the PCA by the concentrations of organic matter and the composition ratio of organic matters from phytoplankton in surface sediments.

  • PDF

Low Voltage Plasma-on-a-Chip for Inactivation of Superbacteria (슈퍼박테리아 감염 치료를 위한 저전압 구동 플라즈마-온-칩)

  • Lim, Towoo;Hwang, Sol;Kim, Youngmin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1249-1250
    • /
    • 2015
  • We report a plasma-on-a-chip (POC) which provides a non-thermal atmospheric plasma for superbacteria infection treatment A three-electrode configuration allows an initiation carrier injection prior to a primary discharge, leading to a significant reduction in a breakdown voltage. A stable non-thermal argon plasma is generated using a pulsed glow discharge and inactivation of anti-biotic resistant bacteria, for example MRSA, is successfully demonstrated by exposing the bacteria to the argon plasma in a couple of minutes.

  • PDF

Interface Development for the Point-of-care device based on SOPC

  • Son, Hong-Bum;Song, Sung-Gun;Jung, Jae-Wook;Lee, Chang-Su;Park, Seong-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This paper describes the development of the sensor interface and driver program for a point of care (POC) device. The proposed pac device comprises an ARM9 embedded processor and eight-channel sensor input to measure various bio-signals. It features a user-friendly interface using a full-color TFT-LCD and touch-screen, and a bluetooth wireless communication module. The proposed device is based on the system on a programmable chip (SOPC). We use Altera's Excalibur device, which has an ARM9 and FPGA area on a chip, as a test bed for the development of interface hardware and driver software.

Analysis of Blood Cell Images Using Smartphone-based Mobile SmartScope (스마트폰 기반 Mobile SmartScope를 이용한 혈구 영상 분석)

  • Park, Choonho;Cho, Myoung-Ock;Lee, Donghee;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.2
    • /
    • pp.25-31
    • /
    • 2012
  • High-performance smartphones, equipped with a digital camera and an application software, can render conventional bench-top laboratory instruments mobile at affordable costs. As the smartphone-based devices are portable and wireless, they have wide applications especially in providing point-of-care (POC) tests in resource-constrained areas. We developed a hand-held diagnostic system, Mobile SmartScope, which consists of a small optical unit integrated with a smartphone. The performance of the SmartScope was favorably compared with that of conventional light microscopy in detecting and quantifying red blood cells. We also evaluated the fluorescence detection limit of the SmartScope incorporated with a blue light-emitting diode and appropriate optical filters by using fluorescently labeled microbeads for intensity calibration.