• Title/Summary/Keyword: A greenhouse culture facility

Search Result 9, Processing Time 0.023 seconds

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

An application and evaluation of Alzheimer's Garden Audit Tool(AGAT) to assess outdoor space of the long-term care facility in Korea (국내 노인전문시설 옥외공간 평가를 위한 외국도구(AGAT)의 적용 후 평가)

  • Tak, Young Ran;An, Ji Yeon;Jung, So Young
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.1
    • /
    • pp.9-22
    • /
    • 2013
  • Purpose: The aging population is the quickly increasing in Korea. Since 2008, the National Long term Care Insurance, a number of long term care facilities have established during short time in Korea. Especially, the environmental assessment tool is important for managing healing environment in a long term care facility for the elderly. Alzheimer's Garden Audit Tool (AGAT) is used to assess whether a garden incorporates those elements and qualities as healing outdoor space. In this paper, we discuss the benefits, limitations, and future directions of the assessment tool for long-term care facilities. Methods : The AGAT audit was done through content analysis by 5 experts from diverse discipline as post occupancy evaluation of a long term care facility located in suburban area. The expert group was asked to describe their comments for modification and improvement in application of AGAT. Results : The results of this study show that it is necessary to refine the instrument's items to better meet the needs of the criteria and items for Korean culture-friendly tool. Especially, greenhouse elements (various plants, birds etc.), multisensory experiences, users-oriented space, programmed activities in garden, and hazards on pathway has somewhat limitation as measurement to assess outdoor of long-term care facilities in Korea. Implications : Consequently, AGAT could be applicable to evaluate the outdoor space of long term care facility in Korea with culturally sensitive revision.

Identification of Major Fungi and Bacterial Species in Solid Medium Drainage for Circulating Hydroponics System (수경재배 배액 재이용을 위한 주요 곰팡이 및 박테리아 종 파악)

  • Lee, Donggwan;Son, Jinkwan;Kang, Taegyeong;Jang, Jaekyung;Park, Minjung;Lee, Taeseok;Lim, Ryugap
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1109-1123
    • /
    • 2020
  • In this study, the amount of harmful fungi and bacteria contained in the drainage and culture medium from the paprika hydroponic facility is identified. In addition, by proposing the necessity of effective purification of discharged drainage, this study attempted to confirm the possibility of drainage reuse. Finally, this study provides basic data on the basis for calculating the need for purification facilities in the future, as well as improvements in horticulture facility for sustainable agriculture. As a result of the analysis, a total of 12 types of fungi were detected in paprika medium and 10 types of fungi were detected in the drainage, and their densities were 130 and 68, respectively. Among the fungi detected in the media and drainage of the paprika hydroponic facility, the fungi with the highest detection frequency are Fusarium, Phytophthora, and Pythium. In the case of bacteria, a total of 2 types of bacteria were detected in the paprika facilities, and the density was 28 and 23, respectively. Therefore, in order to reuse the drainage and settle the circulating hydroponic cultivation system, a water treatment process capable of appropriate treatment is required.

Study on long-term Performance characteristics of various solar thermal system for heating protected horticulture system (태양열 시설원예 난방시스템의 장기성능 특성 분석 연구)

  • Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of this research is to study on the analysis of long-term performance characteristics of various solar thermal system for heating protected horticulture system for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Long term field test for the demonstration was carried out in horticulture complex in Jeju Island. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

Research of environmental condition using ICT-based smart cultivation system during high temperature period (ICT 기반 스마트 재배시스템을 이용한 고온기 표고재배 환경변화 조사)

  • Kim, In-Yeop;Kwon, Hyeong-il;Hwang, In-Ho;Lee, Won-Ho;No, Jong-Hyun;Choi, Sun-Gyu;Ko, Han-Gyu;Koo, Chang-Duk
    • Journal of Mushroom
    • /
    • v.16 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • This study was carried out to separately assess the production of post-culture, germinating, growing, and resting stages of Lentinula edodes grown in a smart cultivation facility based on ICT technology. The cultivation environment of the greenhouse facility was controlled to remain at different set points throughout a range of high ambient temperatures. Production of Sanjo-701-ho, which is a typical summer cultivar, and the new cultivar Sanjo-701-ho were tested in this ICT-based smart cultivation system. Sanjo-701-ho produced 353.7 g/bag of mushrooms from June to October, while Sanjo-701-ho produced 270.4 g/bag. These production amounts were stable over the high-temperature range of $20-35^{\circ}C$.

A Preliminary Study on Energy Consumption Analysis in Storage Space for Exhibition Facility by using Absorption Material (조습재 사용에 따른 전시시설 수장고의 에너지 사용량 분석에 대한 기초연구)

  • Kim, Jinhwan;Hong, Taehoon;Jeong, Kwangbok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.53-59
    • /
    • 2019
  • As solve the shortage problems of storage space for exhibition facilities, the South Korean government is establishing plans to expand storage space for exhibition facilities. From a medium- to long-term perspective, an energy-efficient storage space for exhibition facility is needed to implement efficient state budget execution and achieve national greenhouse gas reduction goals. In this regard, this study analyzed the energy consumption of storage space for exhibition facilities according to the use of absorption materials. To this end, a case study was conducted on 12 storage spaces for exhibition facilities in South Korea. Compared to the storage space using the absorption material, the storage space without using the absorption material showed an increase in HVAC system operation time by 47.50% during summer periods and 58.85% in non-summer periods. In particular, the analysis found that in the case of storage for 'H' exhibition facility, the energy cost was reduced by 2,721,700 won/year after remodeling work using the absorption material. It is expected that the findings of this study can help the government and the person in charge from construction companies to construct energy-efficient storage space room for exhibition facilities.

The Water Quality and Purification Load Assessment of Drain Water of Facility Horticulture Areas (시설원예 배출 배액의 수질환경 평가 및 정화 부하량 산정)

  • Son, Jinkwan;Choi, Dekkyu;Kong, Minjae;Yun, Sungwook;Park, Minjung;Kang, Donghyeon
    • Journal of Environmental Science International
    • /
    • v.28 no.12
    • /
    • pp.1199-1208
    • /
    • 2019
  • Korea's protected horticulture is rapidly increasing in scale due to various advantages such as year-round harvesting, labor savings through automation and shortened culture period, and greater income generation. This study was conducted to investigate the impact of protected horticulture on water quality. The results of this study are expected to provide basic data contributing to improvements towards sustainable agriculture and eco-friendly design of protected horticulture complex. The average T-N and T-P loads from vinyl greenhouses were 286.55± 143.98 mg/L and 59.14±13.77 mg/L, respectively and those from glass greenhouses 380.68 ± 150.41 mg/L and 61.85±20.72 mg/L. The annual discharge of wastewater derived from the monthly discharge from the horticulture greenhouses were estimated at 2597 ton/ha, with the annual phosphorus load amounting to 155.3 kg/ha. The average T-N and T-P loads in the tested greenhouse effluents were in excess of 8.3- and 13.5-fold the standards for the Korean wastewater plant effluent. The waste nutrient solution discharged from a protected horticulture complex can cause water contamination. Therefore, there is a need to conduct follow-up research using a water purification system or a trench method to develop a eco-friendly protected horticulture complex for sustainable agriculture.

Comparison of Environment, Growth, and Management Performance of the Standard Cut Chrysanthemum 'Jinba' in Conventional and Smart Farms

  • Roh, Yong Seung;Yoo, Yong Kweon
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.6
    • /
    • pp.655-665
    • /
    • 2020
  • Background and objective: This study was conducted to compare the cultivation environment, growth of cut flowers, and management performance of conventional farms and smart farms growing the standard cut chrysanthemum, 'Jinba'. Methods: Conventional and smart farms were selected, and facility information, cultivation environment, cut flower growth, and management performance were investigated. Results: The conventional and smart farms were located in Muan, Jeollanam-do, and conventional farming involved cultivating with soil culture in a plastic greenhouse, while the smart farm was cultivating with hydroponics in a plastic greenhouse. The conventional farm did not have sensors for environmental measurement such as light intensity and temperature and pH and EC sensors for fertigation, and all systems, including roof window, side window, thermal screen, and shading curtain, were operated manually. On the other hand, the smart farm was equipped with sensors for measuring the environment and nutrient solution, and was automatically controlled. The day and night mean temperatures, relative humidity, and solar radiation in the facilities of the conventional and the smart farm were managed similarly. But in the floral differentiation stage, the floral differentiation was delayed, as the night temperature of conventional farm was managed as low as 17.7℃ which was lower than smart farm. Accordingly, the harvest of cut flowers by the conventional farm was delayed to 35 days later than that of the smart farm. Also, soil moisture and EC of the conventional farm were unnecessarily kept higher than those of the smart farm in the early growth stage, and then were maintained relatively low during the period after floral differentiation, when a lot of water and nutrients were required. Therefore, growth of cut flower, cut flower length, number of leaves, flower diameter, and weight were poorer in the conventional farm than in the smart farm. In terms of management performance, yield and sales price were 10% and 38% higher for the smart farm than for the conventional farm, respectively. Also, the net income was 2,298 thousand won more for the smart farm than for the conventional farm. Conclusion: It was suggested that the improved growth of cut flowers and high management performance of the smart farm were due to precise environment management for growth by the automatic control and sensor.