• Title/Summary/Keyword: A fire office

Search Result 170, Processing Time 0.031 seconds

A case study on the fire victim in the vehicle by GC/MS through derivatization of cyanide with pentafluorobenzyl bromide (PFBBr) (시안화이온의 pentafluorobenzyl bromide (PFBBr)에 의한 유도체화 후 GC/MS 분석에 의한 차량화재 변사체 사인규명에 관한 사례연구)

  • Lee, Joon-Bae;Shon, Sung Kun;Woo, Sang Hee;Park, Se Yeon;Hwang, Jung Ho;Kwon, O-Seong;Kim, Nam Yi;Paeng, Ki Jung
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • Hydrogen cyanide (HCN) is an extremely toxic gas frequently produced during the incineration of plastics, such as acrylonitrile-butadiene-styrene (ABS). A victim of a fire who has inhaled smoke could have cyanide in the blood. Therefore, cyanide could be a good marker for a post-mortem examination of a fire as well as carboxyhemoglobine (COHb) test of blood samples. For a particular fire case, a burned body with a suicide note was found inside a burned vehicle. Even though the COHb value is conclusive evidence, measuring the COHb for denatured blood might be difficult due to severe thermal denaturation or the formation of methemoglobin (MetHb). To overcome this difficulty, cyanide could be used as an indicator when investigating the death of a fire victim. In this study, gas chromatography/mass spectrometry (GC/MS) was adopted to measure the levels of cyanide in the blood through derivatization with pentafluorobenzyl bromide (PFBBr) under cation surfactant by scan and SIM mode. The concentration of cyanide in the blood of heart blood and brain of the victim was found to be 0.36 µg/mL and 1.20 µg/mL respectively, which was higher than the average value (0.041 µg/mL) found in the blood of 14 people who smoked.

Analysis of Secondary Battery Trends Using Topic Modeling: Focusing on Solid-State Batteries

  • Chunghyun Do;Yong Jin Kim
    • Asian Journal of Innovation and Policy
    • /
    • v.12 no.3
    • /
    • pp.345-362
    • /
    • 2023
  • As the widespread adoption and proliferation of electric vehicles continue, the secondary battery market is experiencing rapid growth. However, lithium-ion batteries, which constitute a majority of secondary batteries, present high risks of fire and explosion. Solid-state batteries are thus garnering attention as the next-generation batteries since they eliminate fire hazards and significantly reduce the risk of explosions. Against this background, the study aimed to analyze research trends and provide insights by examining 2,927 domestic papers related to solid-state batteries over the past decade (2013-2022). Specifically, we used topic modeling to extract major keywords associated with solid-state batteries research and to explore the network characteristics across major topics. The changes in research on solid-state batteries were analyzed in-depth by calculating topic dominance by year. The findings provide an overview of the emerging trends in domestic solid-state battery research, and might serve as a valuable reference in shaping long-term research directions.

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

Analysis on Personnel System and Talent Cultivation System of the Tokyo Fire Department (동경소방청의 인사제도 및 인재양성제도의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.105-114
    • /
    • 2008
  • This study analyzed recruiting system, competence requirement system, promotion system by competence verification, and expert training system in fire officials of the Tokyo Fire Department. The recruiting system is classified into expert and Grade 1, 2, and 3 and all grades are appointed as a fire fighter. According to the competence requirement system, while in office, fire officials who have a certain qualification defined in the recruiting system can change their recruiting classification according to their ability such as Grade $3{\rightarrow}$Grade 2 or 1 or expert, Grade $2{\rightarrow}1$ or expert, or Grade $1{\rightarrow}$expert. The promotion system requires working hard, capability suitable to their grade, and careful verification. Also, a variety of on-site training and qualification systems are provided to reinforce professionalism of staffs and executives.

A Study on the Recognition of Effectiveness and Safety of the Helicopter Aerial Fire Attack (헬기에 의한 산불공중진화 효과 및 안전성 인식 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.97-104
    • /
    • 2012
  • Forest fires were easy to be larger in Korea. So the utilization of aircrafts, especially helicopters, for forest fire attack would be increased gradually. In the forest fire attack process, the improvement of the helicopter aerial fire attack technique and safety were the chief element for efficient forest fire attack. In this study, we surveyed the recognition of pilots who worked in Forest Aviation Office which was responsible for aerial forest fire attack in Korea. Using these survey results, we suggested more efficient and safer method for aerial fire fighting based on actual experience of air attack at the scene of forest fire burning.

Suggestion of the Attached Piping Material Rate for the Mechanical Fire Protection Facilities in Office Buildings (업무용 건축물의 기계소방시설 배관 부속자재 요율 제시)

  • Park, Lyool;Park, Kyung-Soon;Yoon, Hang-Mook
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2018
  • In generally, the estimation work regarding building mechanical service system in comparison with other architectural estimations is time-consuming, and the process is continuously getting more difficult because of the increased usage of the attached piping materials such as fittings and supports in addition to their complicated construction processes. In order to improve this problem, the Korean authority provides a simple method to estimate the attached material rate regarding the main piping material, which is the most time-consuming work in the architectural mechanical estimation. However, to be an applicable method on construction site, a proper conversion rate of the attached piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the suggestion of the material and labor cost rate of the attached piping materials such as the fittings and supports by work types and fitting methods of indoor fire, sprinkler, and extinguishing gas piping work of mechanical fire protection facilities in office buildings that have been designed after 2010.

A Study on the Application Scheme of Fire Identification Considering the Heat Release Rate Characteristics of Inflammable Material (가연물의 발열량 특성을 고려한 화재감식 적용방안에 관한 연구)

  • Kang, Jung-Ki;Oh, Jin-Hee;You, Woo-Jun;Ryou, Hong-Sun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.52-57
    • /
    • 2014
  • The present study suggests the fundamental method for the prediction time of the fire origin by analyzing the combustion phenomenon of inflammable material in the building structure. The heat release rate (HRR) with time variant is evaluated for the interphone as a inflammable material, which is opted from the fire incidents in the stairwell. the fire dynamics simulator (FDS ver. 6.1) is applied in order to analyze the difference of the smoke inflow time to the downstair from the fire event area with various fire pattern. The results show that the maximum inflow time difference for the case of the interphone made from ABS materials is about 4.93 times with the input conditions of heat flux values and the environment in the FDS for the fixed stairwell which composed of total volume $291.3m^3$, floorage $23.3m^2$ and the height of each floor 2.5 m. This research can be practical information for the application method of simulation scheme with experimental data to the fire Identification.

A Genetic Algorithm Approach to the Fire Sequencing Problem

  • Kwon, O-Jeong
    • Journal of the military operations research society of Korea
    • /
    • v.29 no.2
    • /
    • pp.61-80
    • /
    • 2003
  • A fire sequencing problem is considered. Fire sequencing problem is a kind of scheduling problem that seeks to minimize the overall time span under a result of weapon­target allocation problem. The assigned weapons should impact a target simultaneously and a weapon cannot transfer the firing against another target before all planned rounds are consumed. The computational complexity of the fire sequencing problem is strongly NP­complete even if the number of weapons is two, so it is difficult to get the optimal solution in a reasonable time by the mathematical programming approach. Therefore, a genetic algorithm is adopted as a solution method, in which the representation of the solution, crossover and mutation strategies are applied on a specific condition. Computational results using randomly generated data are presented. We compared the solutions given by CPLEX and the genetic algorithm. Above $7(weapon){\times}15(target)$ size problems, CPLEX could not solve the problem even if we take enough time to solve the problem since the required memory size increases dramatically as the number of nodes expands. On the other hand, genetic algorithm approach solves all experimental problems very quickly and gives good solution quality.

Performance for Geothermal Heating & Cooling System by Heatpump in Office Building (사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가)

  • An, Hyung-Jun;Baek, Sung-Kwon;Cho, Chung-Sik;Sohn, Byung-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF