• 제목/요약/키워드: A fire office

검색결과 170건 처리시간 0.028초

고층 사무소건축의 화재안전에 관한 건축계획적 연구 (A Study on the Fire Safety of High-rise Office Buildings in Respect of Architectural Design)

  • 이강훈
    • 한국화재소방학회논문지
    • /
    • 제8권2호
    • /
    • pp.3-15
    • /
    • 1994
  • The purpose of this paper is to present refernce data to be considered in designing for the fire safety of high-rise office buildings. This paper deals with the characteristics of high-rise office buildings in the fire safety aspects, the basic principles for the fire safety of high-rise office building design, and this study is focused particularly on the location of the escape route of core plan for fire safety in high-rise office buildings.

  • PDF

건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 - (Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building -)

  • 남동군;장곡견웅이;사공성호;정종진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Application and evaluation of machine-learning model for fire accelerant classification from GC-MS data of fire residue

  • Park, Chihyun;Park, Wooyong;Jeon, Sookyung;Lee, Sumin;Lee, Joon-Bae
    • 분석과학
    • /
    • 제34권5호
    • /
    • pp.231-239
    • /
    • 2021
  • Detection of fire accelerants from fire residues is critical to determine whether the case was arson or accidental fire. However, to develop a standardized model for determining the presence or absence of fire accelerants was not easy because of high temperature which cause disappearance or combustion of components of fire accelerants. In this study, logistic regression, random forest, and support vector machine models were trained and evaluated from a total of 728 GC-MS analysis data obtained from actual fire residues. Mean classification accuracies of the three models were 63 %, 81 %, and 84 %, respectively, and in particular, mean AU-PR values of the three models were evaluated as 0.68, 0.86, and 0.86, respectively, showing fine performances of random forest and support vector machine models.

업무시설의 화재성상예측을 위한 가연물 조사 및 화재하중 제안 (A Suggestion on the Fire load and Combustible survey for Prediction of Fire in office Facilities)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2019
  • In Korea, buildings are becoming skyscrapers due to restrictions on land. The performance-oriented design was introduced in 2009 for fire safety of such buildings, but the application of the combustible data through engineering design and experiment is a poor reality. Large buildings are used for complex purposes, especially since the density of the office facilities is high, the study conducted a study on the combustible materials of the office facilities and the thermal speed and fire load of the main combustibles of the office facilities were calculated.

  • PDF

사무소 건축물의 화재안전 성능 평가모델 (Performance Assessment Model for Fire Safety Protection of Office Building)

  • 양은범;황영삼;이찬식
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

Toxicological Study for Blood Cyanide and Carboxyhemoglobin Levels in the Fire- related Fatalities

  • Baeck, Seung-Kyung;Kim, Dong-Woo;Kim, Sun-Chun;Park, Woo-Yong;Jin, Kwang-Ho;Chung, Young-Ho;Park, Yun-Shin;Seo, Joong-Seok
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.170.2-170.2
    • /
    • 2003
  • The most common cause of death in fires is the inhalation of noxious gases rather than thermal injury. Carbon monoxide is well-known toxic component in fire atmospheres. However, the importance of hydrogen cyanide(HCN) as a toxic agent in the fire related fatalities(FRF) is under discussion. HCN is known to be produced in fires involving by the pyrolysis of polyacrylonitril (PAN) and other nitrogen-containing polymer. (omitted)

  • PDF

구획화재실험을 통한 온도 변화 예측 기법 연구 (The Study on the Prediction of Temperature Curve by Compartment Fire Experiment)

  • 권오상
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.44-51
    • /
    • 2014
  • 본 연구에서는 건축물에서의 성능기반 화재안전 설계 시에 사용되는 구획공간에서의 화재 성상 분석을 위해서 사무실 공간을 대상으로 하여 $2.4(L){\times}3.6(W){\times}2.4(H)m$의 크기의 구획 Mock-up을 제작하고 구획 내부에는 화재하중 $18.74kg/m^2$을 적용하여 책상, 의자, 컴퓨터 등과 같은 실제 가연물을 배치하여 화재실험을 실시하였다. 화재실험 결과, 구획 공간의 내부 중앙에서는 394~408 s 사이에 $600^{\circ}C$에 도달하였고 구획 입구 모서리에서는 404~420 s 사이에 $600^{\circ}C$에 도달하였다. 본 연구에서는 화재실험을 통해 측정된 온도변화 데이터를 BFD 곡선에 적용하여 화재시 구획 공간내의 온도변화 예측 기법을 분석하고자 하였으며, 화재실험을 통해 BFD 곡선 인자는 최대온도 $900^{\circ}C$, 최대온도 도달시간 7분과 형태계수 1.5로 결정하였다. BFD 곡선에 적용된 사무실 공간의 시간에 따른 온도 곡선은 화재초기에 빠르게 상승한 이후에 약 9분경 이후에 감소하는 형태를 나타내고 있다.

소방시설 관리실태조사에 관한 연구 -공동주택, 상가건축물, 사무소건축물- (A Study on Investigation into Actual Condition of Management in Fire Protection System -Apartment Buildings, Shopping Center, Office Buildings-)

  • 김홍배;한상민;이영재;조병선
    • 한국화재소방학회논문지
    • /
    • 제15권3호
    • /
    • pp.70-76
    • /
    • 2001
  • 현 사회는 안락과 안전을 중요시하고 있다. 그 중, 가장 중요한 부분의 한 부분이 각 건축물에 설치되어 있는 소방시설의 관리와 방화훈련이 얼마나 잘 관리되고 평소 훈련이 되어있는가에 따라서 화재시에 인명과 재산상의 피해를 극소화 할 수 있다. 따라서, 본 연구에서는 공동주택, 상가건축물 및 사무소건축물 등의 소방시설의 점검실태를 설문 조사하였으며, 화재시에 대피훈련을 얼마나 숙지하고 있는가를 조사. 분석함으로써 화재시 손실을 최소화 할 수 있는 방법과, 실질적인 점검 및 훈련방법을 제시한다.

  • PDF