• 제목/요약/키워드: A Single System Design

검색결과 2,206건 처리시간 0.029초

단결정($A1_2O_3$) 성장을 위한 자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 구현 (A Design of Realtime Monitoring System of Automatic gas Control DC-MOTOR for Single Crystal($A1_2O_3$) growth)

  • 이형충;박종국;조현섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2489-2491
    • /
    • 2004
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($A1_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($A1_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas control DC- Motor for single crystal($A1_2O_3$) growth.

  • PDF

단상 다기능 UPS 입.출력 필터 설계 (Design of Input.Output Filter of Single Multifunctional UPS)

  • 김제홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구 (Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard)

  • 김인수;민형복
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

지능형 자동차를 위한 퍼지논리기반 주차 시스템 설계 (Design of Fuzzy Logic Based Parking Systems for Intelligent Vehicles)

  • 학양화;김태균;최병재
    • 한국지능시스템학회논문지
    • /
    • 제18권1호
    • /
    • pp.109-115
    • /
    • 2008
  • 무인자동차에 관한 연구가 활성화되면서 무인 주차 또한 중요한 과제로 대두되고 있다. 본 논문에서는 무인차랑을 위한 주차 편의 시스템 설계를 위하여 퍼지논리시스템에 의한 주차 알고리즘 설계를 제안하고자 한다. 기존의 논문들이 제시한 장단점을 분석하여 새로운 단일 입력을 가지는 퍼지논리시스템을 통한 주차 알고리즘을 설계하고, 시뮬레이션을 통하여 그 효용성을 확인하고자 한다.

가변구조이론을 이용한 편로드 유압실린더의 디지탈제어 (A study on digital control of the single-rod hydraulic cylinder using variable)

  • 이교일;김동춘
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1133-1138
    • /
    • 1991
  • A control of nonlinear system is motivated by the fact that all real plants are nonlinear systems and model identification introduces parameter errors. The purpose of this study is to design a Discrete Variable Structure Controller(DVSC) for single-rod hydraulic cylinder system. The model contains uncertain parameters which we known to lie upper and lower bounds. In the design of DVSC, the boundary layer concept was adopted to reduce cattering. The DVSC was evaluated through digital computer simulation and compared with a VSC (analog controller).

  • PDF

Application of CDM to MIMO Systems: Control of Hot Rolling Mill

  • Kim, Young-Chol;Hur, Myung-Jun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권4호
    • /
    • pp.250-256
    • /
    • 2001
  • This paper deals with a design problem of a decentralized controller with a strongly connected two-input two-output multivariable system. To this end, we present a classical design approach which consists of two main steps: one is to decompose the multivariable plant into two single-input single-output systems by means of the Individual Channel Design (ICD) concept, the other is to design controller of each channel by the Coefficient Diagram Method (CDM) so that it satisfies, especially, time domain specifications such as settling time, overshoot etc.. A design procedure was proposed and then was applied to a 2$\times$2 hot rolling mill plant. Simulation results showed that the proposed method has excellent control performances.

  • PDF

Profile의 Composite와 Multiple Single-Segment Control의 비교 연구 (A Comparison Study between Composite and Multiple Single-Segment Profile Control)

  • 김준호;장성호;라두완
    • 산업경영시스템학회지
    • /
    • 제39권4호
    • /
    • pp.1-6
    • /
    • 2016
  • As manufacturing industries become globalized, product design affects every area of organization. The design sets the goals for a number of different departments, so if it fails to effectively communicate these goals, the entire organization is less efficient. In addition, To communicate clearly, the design must represent a product that meets its technical specification. GD&T (Geometric Dimensioning and Tolerancing) is one of the most important factors, which has an effect on efficiency of manufacture system, in designing products. However, most of designers in different industries are prone to ignore the importance of GD&T. To analyse the importance of GD&T compliance with international standards for design drawing, a comparison analysis of the difference between two methods, composite profile control and multiple single segment profile control, is performed on three different cases and suggests how it used to be more suitable. Composite profile tolerance is specified by a dual feature control frame that has one profile symbol specified with two lines of tolerance information. Whereas a multiple single segment profile control is when two or more single segment profile callouts are used to define the location and/or orientation and/or size and/or form of a part feature. In this study, the following results will be provided : a clear definition and an obvious difference of the tolerance zone, datums and datums sequence and minimization of tolerances. On this study, composite profile tolerance and multiple single segment profile tolerance were discussed. Next steps of research will consist on reaching more accurate results for profile control. Further research will be focused on dealing with the remaining 14 symbols of GD&T.

평지붕 PV거치 시스템의 형태에 따른 풍압영향에 관한 기초연구 (A Basic Study on the Effect of the Wind Pressure according to Form on the Flat Roof mounted PV System)

  • 윤두영;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.105-112
    • /
    • 2013
  • The new renewable energy became popular as a clean and sustainable alternative energy under the circumstances that the entire world is facing severe abnormal climate due to the use of fossil fuel, and among which, solar energy can be obtained anywhere and is not difficult to apply it into the existing buildings, which makes it possible to be widely distributed. However, as PV module is installed into a single plate system, it shows structural weaknesses which are vulnerable to wind load and give loss to design elements in external appearance. Accordingly, this study planned one-step parallel system to complement the problems occurring from a single plate system and used STAR-CCM+ V.8 made by CD-Adapco, a computational fluid dynamics(CFD) simulation tool to measure wind load stability and support based on the design standards for a single plate system and one-step parallel system. Building height was limited to less than 10m and wind speed was given when increasing from 35m/s to 50m/s by 5m/s on PV system installed into the flat roof. In this case, our analysis suggested that step-one parallel system was in class 7-9 according to Beaufort's wind power classification, which did not have an impact on the fixed PV system, and the single plate system is considered to cause risks in designing wind speed in central districts because it is more than wind power class 12.

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구 (A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion)

  • 이관호;김남규;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.