• 제목/요약/키워드: A Single System Design

검색결과 2,212건 처리시간 0.028초

싱글암형 팬터그래프 구조설계를 위한 기구해석기법 개발 (Development of Kinematic Analysis Technique for Structural Design of Single Arm type Pantograph)

  • 정경렬;박수홍;김휘준;배정찬
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.610-618
    • /
    • 2001
  • Pantograph, which collects current from cartenary system, is one of the important parts of high-speed train. Kinematic analysis is one of the key technologies for pantograph design and includes joint trajectories, reaction forces, and the required moment of main shaft calculations. The kinematic analysis, however, is very complex and time-consuming process. In this study PC based pantograph kinematic analysis software using graphical user interface tool was developed for the easy evaluations of kinematic characteristics necessary in pantograph design process.

터보 등화기를 사용한 SSD 시스템 설계와 성능 개선 (Design and Performance Improvement of Simultaneous Single Band Duplex System Using Turbo Equalizer)

  • 안창영;유흥균
    • 한국통신학회논문지
    • /
    • 제39A권1호
    • /
    • pp.28-35
    • /
    • 2014
  • 본 논문에서는 상대국과 자국간의 채널 상황이 악화될 경우에도 통신의 신뢰도를 보장하고 동일 대역에서 동시에 전 이중 통신을 하기 위한 터보 등화기를 결합한 SSD(simultaneous single band duplex)시스템을 제안한다. 본 논문에서 제안하는 시스템은 동일 대역 동시 통신에 의해서 발생하는 자기 간섭 신호를 제거하기 위한 방법으로 RF(radio frequency) Cancellation과 Digital Cancellation을 사용하며 자기 간섭 신호를 효과적으로 제거 한 뒤 터보 등화기를 이용하여 상대국과 자국간의 열악한 채널에 의하여 발생한 신호의 왜곡을 등화 한다. 본 논문에서는 제안하는 터보 등화기를 결합한 SSD 시스템을 설계하고 적응 등화기를 사용한 SSD 시스템과 성능을 비교 분석하였다. 본 논문에서는 제안하는 시스템을 Simulink 프로그램을 이용하여 구성하고 성능을 확인하였다. 본 논문에서 제안하는 터보 등화기를 결합한 SSD 시스템의 성능을 확인한 결과 적응 등화기를 사용하는 SSD 시스템에 비하여 상대국과 자국간의 채널 상황이 열악한 상황에서 ISI(inter symbol interference)에 의한 신호의 왜곡을 보다 효과적으로 등화하고 자기 간섭 신호를 제거하면서 동일 대역에서 동시에 전 이중 통신을 할 수 있는 것을 확인하였다.

빙 해역에서 유조선의 조종 모형시험에 대한 연구 (Maneuvering Experiments in Ice on a Single Screw Tanker)

  • 김현수
    • 대한조선학회논문집
    • /
    • 제45권5호
    • /
    • pp.495-501
    • /
    • 2008
  • Samsung Heavy Industries (SHI) and NRC's Institute for Ocean Technology (IOT) collaborated on a project to predict the performance of a new design for a Suezmax size tanker that had acceptable open water performance but was also capable of operating in ice. The resulting hull form was a single screw, single rudder design with a bulbous bow, modified for operation in ice. An important design consideration is the ability of the ship to maneuver in different ice conditions. This paper presents the results of maneuvering experiments in pack ice and level ice, using a free running model.

An alternative architecture for application-driven fuzzy systems

  • Pedrycz, W.;de Oliveira, J. Valente
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.985-988
    • /
    • 1993
  • An alternative approach to the design of application-driven fuzzy systems is proposed. A broad class of fuzzy systems applications requires a certain fuzzy partition of the input space while it demands for simple numerical quantities. For this class, a dedicated fuzzy system archictecture is presented and a design strategy is proposed. Both the single-input/single-output and multi-input/multi-output cases are considered. Numerical analysis are complete illustrating several aspects of the proposed framework.

  • PDF

The Design and Implementation of an Energy-Smart Home in Korea

  • Xiao, Jin;Boutaba, Raouf
    • Journal of Computing Science and Engineering
    • /
    • 제7권3호
    • /
    • pp.204-210
    • /
    • 2013
  • We present the motivation, design and implementation of a smart home system in Korea. Our system is open, extensible, integrated, intelligent, and usage-centric. We detail the challenges and key design requirements for the smart home system based on our past experiences, and show how convergence system design is a capable methodology for enabling an integrated and multi-faceted home management system that encompasses energy management, home appliance control, environment management, u-health, and living support functionalities under a single unified design. Using energy management as a specific case study, we demonstrate how convergence system design can encapsulate technology heterogeneity and hardware-software disparity without compromising simple yet powerful user interfaces.

한국형 고속전철 차량시스템의 개념설계 (The Conceptual Design of Korea High Speed Train System)

  • 김경택;정경렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.172-180
    • /
    • 1999
  • The major subject of this paper is to develop the concept fur a Korea high speed train system and recommend to train configuration. High speed train configurations are basically concerned traction power(train configurations with concentrated; CPT or distributed Power system: DPT) and train design(single car as compared with articulated bogies). The result of configuration, a advantages and disadvantaged were necessitated by different train configurations; -distributed underfloor power have an increased length for the seats by 15% as compared with the concentrated power trait - articulated trainsets are characterised by less of number of bogies and reduced values of mass, train resistance, noise and vibration. from the result, the optimized train concept combining high seat capacity per train length with low weight and train resistance is 400m long, single -floor train composed of two symmetrically arranged half trainsets. Therefore, at this work recommended distributed train system However, the final decision of Korea high speed train configuration was concentrated power train and articulated bogie system. The configuration of trainset was 20cars included 2 power cars, 4 motorized cars and 14 trailer cars.

  • PDF

리튬이온 배터리의 SOC 제어가 가능한 단상 멀티레벨 컨버터 시뮬레이션 (The Simulation of Single Phase Multi-Level Converter which can control the SOC of Lithium-Ion Battery Units)

  • 김재홍;김일환
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.122-128
    • /
    • 2011
  • This paper proposes a new control scheme of lithium ion battery units based on single phase multi-level converter. In the DC/AC converter applications using battery storage system, it is necessary to control the balancing voltage of individual battery units for high efficiency utilization. Using the proposed control scheme, the DC/AC single phase converter system is applied. To verify the effectiveness of the proposed control scheme, computer simulation is accomplished. In the computer simulation, lithium-ion battery units and single phase multi-level converter system are modeled and carried out using Psim simulation program. It will be helpful for design and applications of energy storage system with lithium-ion battery.

Level control of single water tank systems using Fuzzy-PID technique

  • Lee, Yun-Hyung;Jin, Gang-Gyoo;So, Myung-Ok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.550-556
    • /
    • 2014
  • In this study, for the control of a single water tank system, a fuzzy-PID controller design technique based on a fuzzy model is investigated. For this purpose, a water tank system is linearized as a number of submodels depending on the operating point, and a fuzzy model is obtained by fuzzy combining. Each submodel is approximated as a first order time delay model, and a PID controller is designed using several existing tuning techniques. Then, through the fuzzy combination of this controller using the same method as that of the fuzzy model, a fuzzy-PID controller is designed. For the proposed technique, a simulation is performed using the fuzzy model of a water tank system, and the validity is examined by comparing its performance with that of a PID controller.

단상 계통연계 태양광 인버터용 L-C-L 필터 설계 및 분석 (Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter)

  • 차한주;부우충기엔
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.228-230
    • /
    • 2009
  • Nowadays, the LCL-filter type becomes an attractive grid interfacing for grid-connected Voltage Source Inverter (VSI). LCL-filter can render the current harmonics attenuation around the switching frequency by using smaller inductance than L-filter. This paper presents a study about the LCL-filter design for single-phase grid-connected inverter in Photovoltaic (PV) system. According to the expected current ripple, the inductances of the filter can be determined. Based on the absorbed reactive power on capacitor, the capacitance can be calculated. Due to the theoretical analysis, a LCL-filter based single phase grid connected inverter control system are simulated. The studied simulation results are given to validate the theoretical analysis.

  • PDF

고이득 관측기를 이용한 슬라이딩 모드 제어기 설계 (Output Feedback Sliding Mode Control with High-gain Observer)

  • Oh, Seungrohk
    • 전자공학회논문지SC
    • /
    • 제40권1호
    • /
    • pp.11-18
    • /
    • 2003
  • 불확실성이 있는 표준형으로 표현된 단일 입력 단일 출력 비선형 시스템을 고려하였다. 모델링 불확실성을 극복할 수 있고 상태 변수를 예측할 수 있는 고이득 관측기를 이용하였다. 크기가 제한된 출력만을 이용한 슬라이딩 모드 제어기를 이용하여 폐회로를 안정화하였다. 크기가 제한된 출력만을 이용한 제어기를 사용하여 상태변수에 임펄스와 같은 현상이 나타나는 것을 제거하였다. 제안된 방법은 크기가 제한된 제어기 설계를 쉽게 하였다.