• Title/Summary/Keyword: A Single Room

Search Result 738, Processing Time 0.026 seconds

A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System (냉난방 시스템의 이중선형 시스템에 관한 제어기 설계)

  • 이정석;강민수;김명호;이기서
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

Autonomic Responses Related to the Floor Plan Configurations of One-room Units: Focus on 10 Types of Floor Plan Configurations (원룸 평면 구성에 따른 자율신경계 반응: 사례조사 기반의 10개 평면 유형을 중심으로)

  • Myung, Jee-Yeon;Kim, Kyu-Beom;Jun, Han-Jong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • The aim of this study was to verify differences in autonomic responses that are affected by the configurations of one-room type units using an electrocardiogram (ECG). Accordingly, 43 one-room units that were collected randomly were classified into ten different types of floor plan configurations mainly according to the location of the bathroom and kitchen. An ECG was subsequently measured for each plan type and the average ratio of the LF/HF (Power in low frequency range/Power in high frequency range) was calculated to measure the comfort level of each space. The results revealed a significant statistical difference between the average LF/HF ratio between the plan types (p < 0.05) and provided compelling evidence suggesting that the configuration of the plan may affect the quality of one-room space. This approach appears to be effective in counteracting stress that may exacerbate psychological disorders in single person households.

A Study on the Roof Components of the Traditional Single-Room Square Type Pavilion (한칸형 전통 사각정자의 지붕부 연구)

  • Jeong, Da-In;Kim, Choong-Sik
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.56-64
    • /
    • 2021
  • Pavilion is an important landscape installation in the traditional landscaping and a representative facility that organizes space. To interpret and succeed the traditional landscape space, researches on the shape and structure of the traditional pavilion are also needed. However, researches on the style and structure of the traditional pavilion are difficult to be found. Accordingly this study aimed to identify the structural characteristics of roof part that occupied the largest portion in determining the shape of pavilion. Our research findings are as follows. As a result of analyzing 15 traditional Single-room square pavilions whose structure could be identified, it was found that the main building elements that distinguished the type of roof part in the Single-room square were crossbeam, ridge pole, and baluster. Depending on the presence of roofing members, pavilion was classified into five types: crossbeam, crossbeam+ridge pole, crossbeam+baluster, ridge pole, and baluster. In addition, as a result of analyzing the load and joint that worked on crossbeam based on the shape classification of roof part, it was found that in the traditional Single-room square pavilion, crossbeam was designed to play a balancing role between pillar and load. This study is significant in that it attempted to make a close interpretation of the shape of roof part in the pavilion and the role and function of building elements in terms of size, ratio, and load.

An Analysis of Living Spaces in Domestic Nursing-Home Facilities and a Study of Facility Improvements (국내 전문 요양시설의 거주공간분석 및 시설개선 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.10 no.3
    • /
    • pp.73-77
    • /
    • 2010
  • The study investigated the actual conditions of U.S. nursing-home facilities and Korean nursing homes and conducted a comparative analysis of those nursing facilities to propose the following suggestions for facility improvement: 1.) The number of sickbeds per nursing unit in Korea should be maintained a level of more than 30 beds like the United States, and each rest room in a residential facility should have an area of at least 4.2 square meters. 2.) Each room of a nursing home should be occupied by four or less persons for privacy. 3,) The minimum areas of residential rooms should be larger than 9.2 sq. meters for single rooms and 6.1 sq. meters for quadruple rooms. 4.) Nursing homes for the elderly need to improve rest room spaces and interior fishes to prevent them from falling down and getting hurt and thus help them live safely.

Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments (실내 공기질 평가를 위한 2구획 모델의 개발)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF

Evaluation of Bleeding After Denal Extraction in Patients Taking Single Antiplatelet Treatment

  • Kim, Jae Jin;Kim, Hak Kyun
    • International Journal of Oral Biology
    • /
    • v.40 no.3
    • /
    • pp.147-150
    • /
    • 2015
  • The purpose of this study was to evaluate the effect of single antiplatelet treatment on delayed bleeding, in patients undergoing dental extraction. A total of 154 teeth were extracted in 94 patients with ongoing antiplatelet treatment, who were taking single antiplatelet of either aspirin or clopidogrel. All patients underwent simple dental extraction; local hemostasis was performed with gauze-biting, suturing, and/or application of a local hemostatic agent. Delayed bleeding was recorded in 5 teeth out of a total of 154 teeth after extraction, the incidence of postoperative delayed bleeding being 3.2%. The bleeding was controlled by the patients themselves, through application of pressure with additional gauze-biting. No one visited the doctor or emergency room for hemostasis. These results confirmed that patients taking single antiplatelet drugs may have teeth extracted safely without interruption of the antiplatelet treatment.

Effect of Room-temperature, Calcined Eggshell Reactants on Synthesis of Hydroxyapatite

  • Kang, Tea-Sung;Pantilimon, Cristian M.;Lee, Sang-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.3
    • /
    • pp.204-208
    • /
    • 2015
  • Synthesis of hydroxyapatite (HA) was attempted through a room-temperature reaction of calcined eggshell with phosphoric acid. Ball-milled, calcined eggshell powder, which has a specific surface area of $31.6m^2/g$, was mixed with various concentrations of phosphoric acid at room temperature. The mixtures showed high reactivity and a vigorous exothermic reaction ; the reacted samples showed both $Ca(OH)_2$ and $CaHPO_4$ crystal phases. After heating at temperatures above $400^{\circ}C$, an HA crystal phase was observed in all samples. The calcined eggshell showed a pure CaO single phase, while the $Ca(OH)_2$ phase was only observed in the wet, ball-milled calcined powder. The degree of formation of the HA crystal phase increased as the phosphoric acid concentration and the heating temperature were increased. A mixture with 50 wt% phosphoric acid concentration showed a well-developed HA crystal phase after heat treatment at $800^{\circ}C$, while the formation of a more intensive amorphous phase was observed in the products of the room-temperature reaction.

The Electrical Properties of Ag2Se Single Crystal (Ag2Se 단결정의 전기적 특성)

  • Kim, Nam-oh;Min, Wan-Ki;Kim, Hyung-gon;Oh, Gum-kon;Hyun, Seung-cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.28-31
    • /
    • 2004
  • The results of investigations of Ag2Se single crystal are presented. $Ag_2Se$ crystal was grown by the Bridgman method. The $Ag_2Se$ single crystal was an orthorhombic structure with lattice constance $a=4.333{\AA}$, $b=7.062{\AA}$, $c=7.764{\AA}$. Hall effect shows a n-type conductivity in the $Ag_2Se$ single crystal. The electrical resistivity was $1.25{\times}10^3ohm^{-1}^cm{-1}$ and electron mobility was $-5.48{\times}10^3cm^2/V{\cdot}sec$ at room temperature(RT).

A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design. (단일구획실험을 통한 화재안전설계에 관한 기초적 연구)

  • Kim, Dong;Yoon, Ung-Gi;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

A Study on the Area Composition of the Operating Unit After Remodeling (수술부 리모델링을 통한 공간구성 변화에 관한 연구)

  • Kim, Khilchae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.