• Title/Summary/Keyword: 8.2MHz

Search Result 1,179, Processing Time 0.033 seconds

Wideband Class-J Power Amplifier Design Using Internal Matched GaN HEMT (내부정합된 GaN HMET를 이용한 광대역 J-급 전력증폭기 설계)

  • Lim, Eun-Jae;Yoo, Chan-Se;Kim, Do-Gueong;Sun, Jung-Gyu;Yoon, Dong-Hwan;Yoon, Seok-Hui;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • In order to satisfy the diffusion of multimedia service in mobile communication and the demand for high-speed communication, it is essential to modify and improve high efficiency, wideband and nonlinear characteristic of multiband power amplifier. This research is designed to implement a single-stub matching circuit as a 2nd harmonic one that meets conditions of the Class-J power amplifier. Low characteristic impedance of the single-stub line is necessary to suit conditions of wideband Class-J. This research uses ceramic substrates having high permittivity to implement the single-stub line with low characteristic impedance, which eventually results in an amplifier satisfying the output impedance terms of Class-J in wideband frequency range. This result attributes to use of GaN HEMT packaged with a 2nd harmonic matching circuit and external fundamental circuit. The measurement results of the Class-J amplifier confirms the following characteristics: more than output power of 50 W(47 dBm) in bandwidth of 1.8~2.7 GHz(0.9GHz), maximum drain efficiency of 72.6 %, and maximum PAE characteristic of 66.5 %.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

Effects of Ultrasound and High-Voltage Pulsed Current on Adjuvant-Induced Arthritis in Rats (Adjuvant로 유발된 관절염의 흰쥐에서 초음파와 고전압 맥동 전류 치료의 효과)

  • Lee, Dong-Jin;Lee, Dong-Yeop;Hwang, Don-Young
    • Physical Therapy Korea
    • /
    • v.13 no.3
    • /
    • pp.33-40
    • /
    • 2006
  • The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of $.1m{\ell}$ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in $.1m{\ell}$ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with $.5W/cm^2$ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and $50{\mu}s$ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.

  • PDF

Studies on Diagnosis and Treatment of Major Reproductive Failures in Dairy Cows (젖소 번식장애 주요 유형별 치료방법에 관한 연구)

  • 조성우;김용준;이해이;김용수
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.3
    • /
    • pp.207-217
    • /
    • 2001
  • Diagnosis and treatment of major reproductive failures were carried out for 836 dairy cows of 12 farms in Kimje area from May 1999 to May 2000. Reproductive failures were classified into four categories: uterine diseases, ovarian diseases, combination of uterine and ovarian diseases, and anestrus with corpus luteum (CL), based on the diagnosis by both rectal palpation and ultrasonography (SA 600, Medison, 5.OMHz transducer). 1. Of 102 cows examined, 15 cows were diagnosed as pregnant. Cows with real reproductive failures were therefore 87 cows and the rate of reproductive failures far all the cows of 12 farms was 10.4% (87/836). 2. Of 57 cows with reproductive failures, the cows with uterine diseases were 33 heads (37.9%), with ovarian diseases: 30 heads (34.5%), with combination form: 16 heads (18.4%), and with anestrus with CL: 8 heads (9.2%). 3. Of 87 cows with reproductive failures, 7 cows were slaughtered and 80 cows were treated by hormone or douche. The cows expressed estrus were 74 cows (92.5%, 74/80 heads) and 56 cows were pregnant (70.0%, 56/80 heads) following treatment. 4. The reproductive failures tended to be increased as the period proceeded from 30 days (2.3%, 2/87 heads) to over 120 days (56.3%, 49/87 heads) after parturition. 5. Associated other diseases to reproductive failures were foot diseases(5 cows), joint diseases (5 heads), urovagina (6 heads), and rectovaginal fistula (2 cows) and the rate of occurrence of associated diseases was 20.7% (18/87 heads). 6. No reproductive record was used in 7 farms of 12 farms and 5 farms had no play ground or not used for the cows. These results indicated that diagnosis fur reproductive failures by rectal palpation along with ultrasonography was more accurate than the conventional rectal palpation and brought better result of treatment for major types of reproductive failures. It was also indicated that non-uses of reproductive record and play ground were also important factors in occurrence of reproductive failures.

  • PDF

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

H.264/SVC Spatial Scalability Coding based Terrestrial Multi-channel Hybrid HD Broadcasting Service Framework and Performance Analysis on H.264/SVC (H.264/SVC 공간 계위 부호화 기반 지상파 다채널 하이브리드 고화질 방송 서비스 프레임워크 및 H.264/SVC 부호화 성능 평가)

  • Kim, Dae-Eun;Lee, Bum-Shik;Kim, Mun-Churl;Kim, Byung-Sun;Hahm, Sang-Jin;Lee, Keun-Sik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.640-658
    • /
    • 2012
  • One of the existing terrestrial multi-channel DTV service frameworks, called KoreaView, provides four programs, composed of MPEG-2 based one HD video and H.264/AVC based three SD videos within one single 6MHz frequency bandwidth. However the additional 3 SD videos can not provide enough quality due to its reduced spatial resolution and low target bitrates. In this paper, we propose a framework, which is called a terrestrial multi-channel high quality hybrid DTV service, to overcome such a weakness of KoreaView services. In the proposed framework, the three additional SD videos are encoded based on an H.264/SVC Spatial Base layer, which is compliant with H.264/AVC, and are delivered via broadcasting networks. On the other hand, and the corresponding three additional HD videos are encoded based on an H.264/SVC Spatial Enhancement layer, which are transmitted over broadband networks such as Internet, thus allowing the three additional videos for users with better quality of experience. In order to verify the effectiveness of the proposed framework, various experimental results are provided for real video contents being used for DTV services. First, the experimental results show that, when the SD sequences are encoded by the H.264/SVC Spatial Base layer at a target bitrate of 1.5Mbps, the resulting PSNR values are ranged from 34.5dB to 42.9dB, which is a sufficient level of service quality. Also it is noted that 690kbps-8,200kbps are needed for the HD test sequences when they are encoded in the H.264/SVC Spatial Enhancement layer at similar PSNR values for the same HD sequences encoded by MPEG-2 at a target bitrate of 12 Mbps.

A l0b 150 MSample/s 1.8V 123 mW CMOS A/D Converter (l0b 150 MSample/s 1.8V 123 mW CMOS 파이프라인 A/D 변환기)

  • Kim Se-Won;Park Jong-Bum;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.53-60
    • /
    • 2004
  • This work describes a l0b 150 MSample/s CMOS pipelined A/D converter (ADC) based on advanced bootsuapping techniques for higher input bandwidth than a sampling rate. The proposed ADC adopts a typical multi-step pipelined architecture, employs the merged-capacitor switching technique which improves sampling rate and resolution reducing by $50\%$ the number of unit capacitors used in the multiplying digital-to-analog converter. On-chip current and voltage references for high-speed driving capability of R & C loads and on-chip decimator circuits for high-speed testability are implemented with on-chip decoupling capacitors. The proposed AU is fabricated in a 0.18 um 1P6M CMOS technology. The measured differential and integral nonlinearities are within $-0.56{\~}+0.69$ LSB and $-1.50{\~}+0.68$ LSB, respectively. The prototype ADC shows the signal-to-noise-and-distortion ratio (SNDR) of 52 dB at 150 MSample/s. The active chip area is 2.2 mm2 (= 1.4 mm ${\times}$ 1.6 mm) and the chip consumes 123 mW at 150 MSample/s.

High Efficiency Triple Mode Boost DC-DC Converter Using Pulse-Width Modulation (펄스폭 변조를 이용한 고효율 삼중 모드 부스트 변환기)

  • Lee, Seunghyeong;Han, Sangwoo;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • This paper presents a high efficiency, PSM/DCM/CCM triple mode boost DC-DC converter for mobile application. This device operates at Pulse-Skipping Mode(PSM) when it enters light load, and otherwise operate the operating frequency of 1.4MHz with Pulse-Width Modulation(PWM) mode. Especially in order to improve the efficiency during the Discontinuous-Conduction Mode(DCM) operation period, the reverse current prevention circuit and oscillations caused by the inductor and the parasitic capacitor to prevent the Ringing killer circuit is added. The input voltage of the boost converter ranges from 2.5V ~ 4.2V and it generates the output of 4.8V. The measurement results show that the boost converter provides a peak efficiency of 92% on CCM and 87% on DCM. And an efficiency-improving PWM operation raises the efficiency drop because of transition from PWM to PFM. The converter has been fabricated with a 0.18um Dongbu BCDMOS technology.

The evaluation on the biological safety of diagnostic ultrasound using radiation-induced apoptosis in the external granular layer of mouse cerebellum (마우스 소뇌과립층의 apoptosis를 지표로 한 진단용 초음파의 안전성 검증)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jo, Sung-kee;Chung, Chi-young;Son, Chang-ho;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.628-634
    • /
    • 1999
  • We have studied, by a nonisotopic in situ end-labeling(ISEL) technique, frequency of apoptosis in the external granular layer(EGL) of the cerebellum of immature mice by ${\gamma}$-rays irradiation from $^{60}Co$ or diagnostic ultrasound exposure. The total number of normal cells and cells showing morphological features of apoptosis were counted. The frequency of apoptotic cells was expressed as a percentage of the total number of cells in EGL. The extent of changes following 200 cGy(1090 cGy/min) was studied at 2, 4, 6, 8, 12, or 24 hours after exposure. The maximal frequency was found 6~8 hours after exposure. The immature mice that received 18, 36, 54, 108, 198, 396 cGy of ${\gamma}$-rays or diagnostic ultrasound(7.5MHz, 4.2mW, $I_{SPTA}=7.9mW/cm^2$, $I_{SPTA}=114.3W/cm^2$) for 10 or 30 minutes were examined 6 hours after irradiation. Measurements performed after ${\gamma}$-ray irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model ; frequency of apoptotic cell in the EGL was y = $(0.1349{\pm}0.01175)D$+$(-0.0001522{\pm}0.0000334)D^2$+0.048($r^2$ = 0.981, D = dose in cGy). In the experiment of ultrasound exposure, the frequency of apoptotic cell was $0.106{\pm}0.130$(10 minutes exposure) and $0.167{\pm}0.220$(30 minutes exposure). We estimated the relative dose of the yield from the experiment with ultrasound by substituting the yield from ultrasound exposure into the curve from the ${\gamma}$-irradiation. The relative dose of ultrasound exposure compared with ${\gamma}$-irradiation were 0.432 cGy(10 minutes exposure) and 0.885 cGy(30 minutes exposure). We have found that there is no evidence to indicate that diagnostic ultrasound involves a significant risk.

  • PDF

Effects of Atmospheric Pressure Microwave Plasma on Surface of SUS304 Stainless Steel

  • Shin, H.K.;Kwon, H.C.;Kang, S.K.;Kim, H.Y.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.268-268
    • /
    • 2012
  • Atmospheric pressure microwave induced plasmas are used to excite and ionize chemical species for elemental analysis, for plasma reforming, and for plasma surface treatment. Microwave plasma differs significantly from other plasmas and has several interesting properties. For example, the electron density is higher in microwave plasma than in radio-frequency (RF) or direct current (DC) plasma. Several types of radical species with high density are generated under high electron density, so the reactivity of microwave plasma is expected to be very high [1]. Therefore, useful applications of atmospheric pressure microwave plasmas are expected. The surface characteristics of SUS304 stainless steel are investigated before and after surface modification by microwave plasma under atmospheric pressure conditions. The plasma device was operated by power sources with microwave frequency. We used a device based on a coaxial transmission line resonator (CTLR). The atmospheric pressure plasma jet (APPJ) in the case of microwave frequency (880 MHz) used Ar as plasma gas [2]. Typical microwave Pw was 3-10 W. To determine the optimal processing conditions, the surface treatment experiments were performed using various values of Pw (3-10 W), treatment time (5-120 s), and ratios of mixture gas (hydrogen peroxide). Torch-to-sample distance was fixed at the plasma edge point. Plasma treatment of a stainless steel plate significantly affected the wettability, contact angle (CA), and free energy (mJ/$m^2$) of the SUS304 surface. CA and ${\gamma}$ were analyzed. The optimal surface modification parameters to modify were a power of 10 W, a treatment time of 45 s, and a hydrogen peroxide content of 0.6 wt% [3]. Under these processing conditions, a CA of just $9.8^{\circ}$ was obtained. As CA decreased, wettability increased; i.e. the surface changed from hydrophobic to hydrophilic. From these results, 10 W power and 45 s treatment time are the best values to minimize CA and maximize ${\gamma}$.

  • PDF