• Title/Summary/Keyword: 740 nm

Search Result 46, Processing Time 0.024 seconds

Effects of Low-level Light Therapy at 740 nm on Dry Eye Disease In Vivo

  • Goo, Hyeyoon;Kim, Hoon;Ahn, Jin-Chul;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.50-58
    • /
    • 2019
  • Background and Objectives Low-level light therapy (LLLT) is an application of low-power light for various purposes such as promoting tissue repair, reducing inflammation, causing analgesia, etc. A previous study suggested the effect of light emitting diode (LED) light with the wavelength of 740 nm for promoting wound healing of corneal epithelial cells. This current study aimed to confirm the effect of LLLT for managing inflammation of a dry eye disease (DED) mouse model. Materials and Methods A total of 50C57BL/6 female mice were randomly grouped into 5 groups to compare the effect of LLLT:1) Control group, 2) Only LLLT group, 3) Dry eye group, 4) LLLT in dry eye group, and 5) Early treatment group. DED was induced with 4 daily injections of scopolamine hydrobromide and desiccation stress for 17 days, and LLLT at 740 nm was conducted once every 3 days. To analyze the effect of LLLT on the DED mouse model, tear volume, corneal surface irregularities, and fluorescence in stained cores were measured, and the level of inflammation was assessed with immunohistochemistry. Results The DED mouse model showed significant deterioration in the overall eye condition. After LLLT, the amount of tear volume was increased, and corneal surface irregularities were restored. Also, the number of neutrophils and the level of inflammatory cytokines significantly decreased as well. Conclusion This study showed that LLLT at 740 nm was effective in controlling the corneal conditions and the degree of inflammation in DED. Such findings may suggest therapeutic effects of LLLT at 740 nm on DED.

High Performance 50 nm Metamorphic HEMTs for Millimeter-wave Applications (밀리미터파 응용을 위한 우수한 성능의 50 nm Metamorphic HEMTs)

  • Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.116-120
    • /
    • 2012
  • We reported on a high performance InGaAs/InAlAs metamorphic HEMT with 50 nm gate length on a GaAs substrate. The fabricated $50nm{\times}60{\mu}m$ MHEMT showed good DC and RF characteristics. Typical drain current density of 740 mA/mm and extrinsic transconductance(gm) of 1.02 S/mm were obtained with our devices. The current gain cut-off frequency(fT) and maximum oscillation frequency(fmax) obtained for the fabricated MHEMT device were 430 GHz and 406 GHz, respectively.

Wavelength tuning at a pulsed Ti:sapphire laser with a birefringent filter (복굴절 필터를 사용한 펄스동작 Ti:sapphire 레이저의 파장 가변특성)

  • 김병태;이형권
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.450-455
    • /
    • 1997
  • A pulsed Ti:sapphire laser with a Z-folded cavity, which was pumped by a freqeuncy-doubled Nd:YAG laser, was developed. It shows 120 nm wavelength tuning range from 740 nm to 860 nm with 90 nm FWHM under a pumping energy of 3 mJ with 18% output coupler. Using a birefringent filter, the effective efficiency was improved about 10 times compare to without a birefringent filter. The output energy obtained was $\365mu$Jwith 4 nm FWHM. And the wavelength tuning range was broadened to about 160 nm within an output energy fluctuation of $\pm$10%.

  • PDF

Output characteristics of a pulsed Ti:sapphire laser (펄스동작 Ti : sapphire 레이저의 출력특성)

  • 김병태;이형권
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.390-396
    • /
    • 1996
  • A pulsed Ti : sapphire laser with a Z-folded cavity, which was pumped by a frequency-doubled Nd : YAG laser, was developed. A laser output energy of 822 $\mu$J with a pulsewidth of 5 ns and an output efficiency of 27.4% was obtained at a center wavelength of 790 nm using an output coupler of 18% reflectance. The slope efficiency was 35%. The output beam diameter was 0.9 mm, and the divergence angle was 1.8 mrad. The spectrum tunability was about 120 nm from 740 nm to 860 nm with a FWHM of 90 nm at an 18% output coupler and a pumping energy of 3 mJ.

  • PDF

Studies on the Photo-electrochemical Properties of Ti$O_{2-x}$ Thin Films (Ti$O_{2-x}$ 박막의 광-전기화학적 성질에 관한 연구)

  • Q Won Choi;Chu Hyun Choe;Ki Hyung Chjo;Yong Kook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.582-591
    • /
    • 1985
  • The thin films of Ti$O_{2-x}$, were prepared by vapor oxidation and Ti$O_2$ single crystal was reduced by heating in argon atmosphere. The photo-electrochemical properties of these samples were studied. When the photocurrent was scanned in 1M NaOH electrolyte solution, several peaks were observed in the vicinity of 320nm in the UV-region and in the vicinity of 520nm, 620nm, and 740nm in the visible-region. Contrary to the previous suppositions, those peaks were produced by the second-order lines from the grating monochromator.

  • PDF

ESTIMATION OF PHOTOSYNTHETIC LIGHT USE EFFICIENCY IN A SINGLE LEAF BY ANALYZING NARROW-BAND SPECTRAL REFLECTANCE

  • Suh, Kyehong
    • Journal of Photoscience
    • /
    • v.7 no.4
    • /
    • pp.139-142
    • /
    • 2000
  • To examine applicability of some optical indices from reflectance to estimate photosynthetic light use efficiency, photosynthesis, and narrow band spectral reflectance were simultaneously measured at various intensities of light with mongolian oak leaves. Narrow band of the broad-band NDVI was better than photochemical reflectance index and simple ratio to estimate photosynthetic light use efficiency in this study. Changes in spectral reflectance were detected at several wavelengths (540nm, 690nm, 740nm, and 800nm) associated with physiological status of plant leaves that could be components for new optical indices.

  • PDF

Frequency conversion using anomalous dispersion of organic material (유기재료의 이상분산을 이용한 파장변환)

  • Kim, Eung-Soo;Kim, Min-Sung;Kang, Shin-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.103-108
    • /
    • 2005
  • Second harmonic generation(SHG) by guided phase matching is observed in waveguide structure using the anomalous dispersion of a poled polymer. The second harmonic TM$_{0}$ guided mode could be generated from the fundamental TM$_{0}$ guided mode and then the second harmonic power was higher than any other phase matchable mode because the overlap integral between the fundamental and the second harmonic wave was the largest in the theoretical analysis. Near UV SHG(370 nm) was obtained from the fundamental wavelength of Ti-sapphire laser(740 nm).

Optical reflectance of TiO2/SiO2 multilayer coating flat mirrors (TiO2/SiO2 다층 박막 평판 mirror의 광학적 반사)

  • Lee, Chanku;Lee, Sudae;Joung, Maengsig
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.75-78
    • /
    • 2002
  • Thirty three layer $TiO_2/SiO_2$ coating mirrors with high reflectance through a 620~820nm wavelength range have been designed and fabricated by electron beam evaporation method. Multilayer films were deposited on glass(BK7) and sequentially. The high reflector design is based on alternating high and low refractive index layers. $n_H$ and $n_L$ such that a "stopband"(or area of high reflectivity) is created that is centered around the design wavelength. ${\lambda}_0$. The measured transmittance spectrum with an incident wavelength at an incident angle of $40^{\circ}{\pm}7^{\circ}$ exhibited a reflectance of 99.9% at the wavelength of 620~820nm but high peak transmittance in the wavelength region from 700 to 740nm.

  • PDF

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Utilization of Near Infrared Spectroscopy for Analysis of Proximate Composition and Starch in Alaska Pollack Surimi (명태 수리미의 일반성분 및 전분의 분석을 위한 근적외선 분광분석법의 이용)

  • Song Ho Su;Lee Keun Tai;Park Seong Min;Hwang Sun Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.4
    • /
    • pp.321-326
    • /
    • 2002
  • Near infrared spectroscopy (NIR), is recently applied to analysis of food, and it gives non-destructive and highly reproducible results. The objectives of this study were to assay protein, lipid and starch content in Alaska pollack surimi and to investigate application in seafood. NIR spectra showed the absorbance signal at 1,510 nm, 2,050 nm, 2,170 nm and 2,180 nm for protein, and signal were increased with protein content. Standard error of equation (SEE) was 0,296 and standard error of prediction (SEP) was 0.327. In analysis of lipid in Alaska pollack surimi by NIR, near infrared spectra of lyophilized Alaska pollack surimi were scanned and the signals of absorbance from C-H functional groups in lipid were identified at 1,730 nm, 1,740 nm and 2,300 nm and these signals were risen as Increasing lipid contents of Alaska pollack surimi as samely protein. SEE and SEP were 0.319, 0,353, respectively. In starch analysis using NIR the signals of starch distinctly changed at wavelength of 1,450 nm and 1,950 nm. Collected values of SEE and SEP were 0.304 and 0.318, respectively and the range of errors was $0.0186\~0.6470$ in starch contents.