• 제목/요약/키워드: 7.0 T MRI

검색결과 221건 처리시간 0.024초

SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발 (Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses)

  • 황성민;김기웅;강찬석;이성주;이용호
    • Progress in Superconductivity
    • /
    • 제13권2호
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.

새로운 ABCD1 유전자의 돌연변이를 가지는 소아 대뇌형 부신백질이영양증 1례 (A Case of Childhood Cerebral Form Adrenoleukodystrophy with Novel Mutation in the ABCD1 Gene)

  • 신영림
    • 대한유전성대사질환학회지
    • /
    • 제12권1호
    • /
    • pp.49-53
    • /
    • 2012
  • X 연관 부신백질이영양증(adrenoleukodystrophy, ALD)은 과산화소체베타산화과정(peroxisomal ${\beta}$-oxidation)의 장애로 매우긴사슬지방산(very long chain fatty acids, VLCFA)이 신경계의 백질과 부신피질 및 고환에 축척된다. 이 질환은 과산화소체막단백질(peroxisomal membrane protein)을 형성하는 Xq28에 위치하는 ATP-binding cassette, subfamily D, member 1 (ABCD1) 유전자 돌연변이에 의해 주로 발생한다. X 연관 ALD는 다양한 임상양상을 보이는데 전형적인 소아대뇌형 부신백질이영양증은 10세 이전의 남아에서 대뇌백질에 빠르게 진행하는 탈수초현상을 보인다. 8세 된 남자 환아로 정상발달과정을 보이던 중 초등학교 입학 후에 집중장애와 산만한 모습으로 인해 주의력결핍과다활동장애로 진단받고 치료를 받았었다. 환아는 내원 8개월 전부터 말이 어눌해 지고 걸을 때 오른 발을 끌며 자주 넘어지는 모습을 보여 내원하였고 오른쪽 상, 하지의 근력이 떨어지는 양상이 관찰되었다. 검사상 부신기능저하증 소견을 보였으며 혈청 지방산 분석검사에서는 C26:0, C42:0/C22:0, C26:0/C22:0가 증가하였다. 뇌 자기공명영상에서는 T2와 FLAIR 강조영상에서 양측의 두정후두부의 백질과 소뇌의 백질에서 대칭적으로 고신호강도를 보였다. 환아는 부신백질이영양증로 진단하였고 ABCD1 유전자 분석 검사에서 새로운 c.983delT (p.Met329CysfsX7) 돌연변이가 확인되었다. X 연관 ALD는 유전자형과 표현형에 연관성이 없으며 다양한 임상양상을 보이기 때문에 환자들마다 임상증상을 잘 관찰해야 하며 향후 유전자 기능을 좀 더 파악하고 임상증상에 영향을 주는 다른 요소에 대한 연구가 필요할 것이라 사료된다.

  • PDF

새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구 (The Synthesis and MR Properties of New Macromolecular MR Contrast Agent)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.35-40
    • /
    • 2002
  • 목적 : 새로운 개념의 macromolecular MR 조영제를 개발하여 자기이완적 특성 및 조직특이성 조영제로서의 가능성을 탐색해 보고자 하였다. 대상 및 방법 : Phthalocyanine (PC)을 상자성 원소의 배위자로 선택하였다. 2.01g (5.2 mmol)의 Phthalocyanine을 0.37 g(1.4mmo1)의 Mn chloride와 $310^{\circ}C$에서 36시간동안 반응시킨 후 혼합물을 크로마토그래피(CHC13/CH3OH 98/2 v/v, Rf, 0.76)로 정제하여 1.04 g (46%)의 MnPC (분자량 2000)를 얻었다. 0.1 mM로 희석시킨 MnPC를 1.5T(64MHz) MR 장비를 이용하여 T1/T2 자기이완율을 측정하였다. MnPC의 MR 영상 특성을 알아보기위해 1.5T MRI에서 스핀반향 기법(TR/TE= 500/14 msec)과 경사에코 기법중 FLASH 기법(TR/TE=80/4 msec, flip angle=60)을 사용하여 매 10분 간격으로 최고 4시간까지 연속적으로 토끼의 간에서 영상을 획득하였다. 농도별 차이를 알아보기위해 MnPC를 20 mM, 50 mM, 100 mM로 희석하여 사용하였다. 결과 : MnPC의 1.5 T(64 MHz)에서의 자기이완율은 Rl : 7.28 $mM^{-1}S^{-1}$, R2=55.56 $mM^{-1}S^{-1}$으로 small molecular weight 조영제인 Gd-DTPA의 Rl(=4.8 $mM^{-1}S^{-1}$), R2(=5.2 $mM^{-1}S^{-1}$) 값과 비교할 때 T1/T2 자기이완율이 매우 컸다. 스핀반향과 FlASH 기법 모두에서 조영증강은 조영제 주사후 약 10분 정도에 최고치에 달한 후 약 2시간 정도까지 유지하였다. MnPC는 small molecular weight의 간특이성 조영제들인 Gd-EOB-DTPA, Gd-BOPTA 및 MnDPDP과 비교할 때 조명증강을 유지하는 시간이 훨씬 더 긴 특성을 보였다. MnPC는 시간 경과에 따라 담도로 배출되었다. 결론 : 새로운 종류의 macromolecular MR agent인 MnPC를 자체 개발하였고 자기이완율을 측정한 결과 T1/T2 효과가 기존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다.

  • PDF

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Comparative Analysis of Spontaneous Infectious Spondylitis : Pyogenic versus Tuberculous

  • Lee, Yangwon;Kim, Bum-Joon;Kim, Se-Hoon;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권1호
    • /
    • pp.81-88
    • /
    • 2018
  • Objective : Spondylitis is often chemotherapy resistant and requires long-term treatment. Without adequate chemotherapy, the outcome can be fatal or result in severe neurologic damage. Therefore, differentiating the etiology of spondylitis is very important, particularly in spontaneous cases. As the prevalence of tuberculosis in Korea has decreased in recent years, updated clinical research about spondylitis is warranted. Methods : From April 2010 to March 2016, data from spondylitis patients were collected retrospectively. In total, 69 patients (51 with pyogenic spondylitis and 18 with tuberculous spondylitis) were included. Clinical data, laboratory findings including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) level, measurements of Cobb angles at the initial and final follow-up, and radiologic features on magnetic resonance imaging (MRI) scans were evaluated. To test differences between the pyogenic and tuberculous groups, numerical data were compared using the student's t-test and Mann-Whitney U test, and categorical data were compared using the chi-square test and Fisher's exact test. Results : The patients' mean age was 60.0 years. Male sex was slightly predominant (56.5%). There was no difference in mean age and sex between the two groups. The pyogenic group had a relatively higher proportion of immunocompromised patients. The peak CRP value was higher in the pyogenic group than in the tuberculous group (14.08 mg/dL and 8.50 mg/dL, respectively, p=0.009), whereas the ESR was not significantly different between the groups (81.5 mm/h and 75.6 mm/h, respectively, p=0.442). Radiologically, the presence of disc space sparing and vertebral body collapse differed between the groups. In the tuberculous group, the disc was more commonly preserved on contrast-enhanced MRI (50% and 23.5%, respectively, p=0.044), and vertebral body collapse was more common (66.6% and 15.7%, respectively, p<0.001). The mean length of hospitalization was longer in the pyogenic group (56.5 days and 41.2 days, respectively, p=0.001). Four mortality cases were observed only in the pyogenic group. The most commonly isolated microorganism in the pyogenic group was Staphylococcus aureus(S. aureus) (methicillin susceptible S. aureus and methicillin resistant S. aureus [MRSA] in 8 and 4 cases, respectively). Conclusion : The clinical and radiological manifestations of spontaneous spondylitis differ based on the causative organism. Pyogenic spondylitis patients tend to have a higher CRP level and a more severe clinical course, whereas tuberculous spondylitis patients present with destruction of the vertebral body with disc sparing more frequently. The presence of MRSA is increasing in community-acquired spondylitis cases.

Analysis of Corticospinal Tract Injury by Using the Diffusion Tensor Imaging of 3.0 T Magnetic Resonance in Patients with Hypertensive Intracerebral Hemorrhage

  • Cho, Hee-Cheol;Son, Eun-Ik;Lee, So-Young;Park, Gi-Young;Sohn, Chul-Ho;Yim, Man-Bin
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권5호
    • /
    • pp.331-337
    • /
    • 2005
  • Objective : The purpose of this study is to identify correlations between diffusion tensor imaging[DTI] and motor improvement by quantifying and visualizing the corticospinal tract on DTI to predict motor impairment in patients with hypertensive intracerebral hemorrhage[ICH]. Methods : Fifteen normal subjects and 7 patients with hypertensive ICH were examined and the latter were treated surgically. DTI was performed with a 3.0 T MRI. The region of interest[ROI] from the posterior limbs of both internal capsules was measured on a fractional anisotropy[FA] map, and the ratios of ROIs were calculated. Tractography, 3-dimensional DTI was then constructed. Motor impairment was assessed on admission and 2weeks after stroke by the Motricity Index[MI]. The FA ratio, tractography and score on MI were analyzed for correlations. Results : The FA ratio from the initial DTI did not show a linear correlation with motor impairment. However, after 2weeks, patients with high FA ratios showed high degrees of motor recovery, regardless of the initial severity, and patients with low FA ratios showed low recovery rates. Otherwise, a relationship between the amount of hematoma and the degree of motor recovery could not be determined. On tractography, injury of the corticospinal tract could be visualized and estimated 3-dimensionally. Conclusion : FA ratio analysis and tractography constructed from DTI may be useful in understanding corticospinal tract injury and in predicting the recovery from motor impairment in patients.

정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교 ([ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System)

  • 강영혜;이윤미;박선원;서창해;임명관
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.79-85
    • /
    • 2004
  • 목적: 정상인 뇌에서 측정한 신호대잡음비율, 주사 시간, 그리고 대사물질의 상대 비율을 이용하여 서로 다른 1.5T 자기공명영상기기에서의 수소자기공명분광법의 유용성과 차이점을 알아보고자 하였다. 대상 및 방법: 총 10명의 정상인 (20-45세)에서 PROBE (PROton Brain Exam) 라는 자동화된 방법을 이용하여 수소 자기공명분광술을 시행하였다. 수소 자기공명분광술은 1 channel 코일의 기존의 자기공명영상기기(Signa Horizon)와 1 channel 및8 channel 코일을 이용한 다른 자기공명영상기기(Echospeed plus with EXCITE)에서 3번씩 시행하였다. 각각 방법에서 팬톰과 생체에서의 스펙트럼의 신호 대 잡음비와 주사 시간을 측정하였다. 모든 정상인에서 뇌의 2 부분, 즉 기저핵과 심부백질 부위를 위의 방법으로 각각 검사하였고 각 부위에서 대사물질의 상대적인 비율의 차이(NAA/Cr, Cho/Cr, mI/Cr)를 측정하였다. 모든 스펙트럼에서 STEAM(Stimulated Echo Acquisition Method) 방법을 이용하여 다음과 같은 조절치로 검사하였다: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG=64/128, NEX=2/8 (Signa/Echospeed). 결과 : 신호대잡음비율은 Echo speed 기계에서 약 $30\%$이상 더 높았고 주사 시간은 거의 같았다. 각각의 방법에서 모두에서 믿을만한 스펙트럼을 얻었고 정상 뇌의 2부분에서 얻은 스펙트럼 모양과 대사물질의 상대적인 비율의 차이는 서로 의미있는 차이를 보이지 않았다 (p>0.05). 결론: 새로운 자기공명영상기기와 코일을 이용한 수소자기공명분광소견은 매우 믿을만 하였고 높은 신뢰성과 재현도를 보였으며 기존의 자기공명영상기기의 수소자기공명분광소견과 의미있는 차이는 없었다.C의 높은 T2 자기이완율은 T2 강조영상에서의 정상 간실질의 신호강도를 감소시켜 간실질과 VX2 암종의 구분을 쉽게 하였다. MnPC 주입시 T1 강조영상에서는 간세포 특이성 조영제의 주입시보다 종양의 경계가 명확하였고, 조영증강은 주입후 최소한시간 이상 높게 유지되었다. 결론 : MnPC가 간세포로 흡수되어 담관으로 배설된다는 사실은 Mn-DPDP와 유사한 특성이며 이는 MnPC가 새로운 간특이성 조영제임을 확인시켜 준다. 또한 MnPC의 R2값이 기존의 조영제에 비해 매우 크다는 사실은 T1 조영제로서 뿐만 아니라 T2 조영제로서의 사용 가능성을 보여준다. 이러한 사실들을 좀더 정확하게 뒷받침하기 위해서는 임상적으로 사용되기 이전에 생체 내 그리고 시험관내 연구가 더 필요하며 다른 동물모델에서의 추가적인 연구가 요구된다.유발 가능자를 1차 적으로 선별 할 수 있는 지표 개발 가능성을 제시하였다고 사료된다.대상자 선정이 어려워서 자원자를 대상으로 연구가 행해졌다. 둘째. 적은 수의 연구 대상자를 대상으로 연구가 행해졌다. 셋째. 연구기간이 짧았던 까닭에 좀더 상세한 사례 연구가 이루어질 수 없었다 좀 더 신뢰할 수 있는 표본 추출 방법을 통하여 선정된, 많은 연구 대상자를 가지고, 심도 있는 연구가 추후 반복적으로 이루어져야 할 것이다.더욱 더 발전을 거듭하고 있으며, 외식은 여행과 여가 활동의 필수적인 요소로써 그 역할을 일조하고 있다. 이와 같은 여가시간의 증가는 독신자들에게는 좀더 많은 여유시간을 가족을 이루고 있는 가족구성원들에게는 가족과의 유대를 강화하는 휴식과 오락의 소비 트렌드를 창출시켰다. 이와 더불어 외식은 식사를 해결하기 위한 단순한 수단에서 벗어나 동기와 동반자에 따라 달라지는 행동 패턴을 나타내고 있으며, 연령과 목적에 따라 세분화되는 분명한 선호도를 나타낸다. 지난 10여 년간 외국으로부터 수입된 다양한 음식과 레스토랑 업태 등은 우리나라의 외식문화 발전과 소비자들의 외식 선택

  • PDF

유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구 (A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.201-208
    • /
    • 2018
  • 본 연구는 Image J 프로그램을 사용하여 유속증가 자기공명영상기법의 숙임각 변화에 따른 SNR와 CNR을 측정하여 최적의 숙임각을 알아보기 위해 연구하였다. 총 30명의 정상인 지원자를 대상으로 1.5T 자기공명영상기기(Philips, Medical System, Achieva)를 이용하여 뇌동맥검사 후 평가를 실시하였다. 분석 방법으로 유속증가 자기공명 혈관 조영술에 대하여 4 부위에 관심영역을 설정하고 SNR와 CNR을 평가하였다. 5가지 숙임각에서의 정량적 분석으로 SNR과 CNR에 대한 통계적 유의성은 일원분산분석으로 계산되었으며, 사후 분석으로는 Bonferroni 법을 적용하였고, 통계에 사용된 프로그램은 SPSS 14.0을 이용하여 p 값을 0.05 이하일 때 유의성을 두었다. 본 실험에 대한 결과로서 전교통동맥(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), 후교통동맥 (SNR: $863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR: $1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$), 중대뇌동맥(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$)의 값으로 $25^{\circ}$에서 가장 높은 신호강도를 보였다(p<0.05). 작은 혈관 묘출로서 a1, a2, a3, p1, p2, p3, m1, m2, m3 값 또한 동일한 결과 이었다(p<0.05). 사후분석결과로, 숙임각에서 $25^{\circ}$ 기준으로 $10^{\circ}$, $15^{\circ}$, $20^{\circ}$에서 유의성 있는 결과를 얻었지만(p=0.000) $30^{\circ}$에서는 유의한 차이가 없었다(p>0.05). 결론적으로, 본 연구에서 $30^{\circ}$에서는 신호강도가 떨어지기 때문에 뇌혈관 자기공명조영술에서 최적의 숙임각은 $25^{\circ}$로 나타냈다.

1.0 Tesla 자기 공명 진단 장치의 개발 (Development of 1.0 Tesla Compact MRI System)

  • 이흥규;오창현;안창범;장용호;신동희;이근남;장기현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

3차 의료기관 응급의료센터로 전원되는 환자에 대한 조사연구 - 중복 재검사에 관한 조사 - (A study on patients transferred to emergency medical center of university hospital -About reexamination status of patients transferred -)

  • 유순규
    • 한국응급구조학회지
    • /
    • 제3권1호
    • /
    • pp.20-32
    • /
    • 1999
  • The purpose of this retrospective research of 603 patients who were transferred to the emergency medical center of university hospital from 1 Jan, 1998 to 31 Jan, 1998 was making of basic data for emergency medical transfer system improvement countermeasure and the point at issue of overlapping reexamination ststus of patients transfered to emergency medical center of university hospital from 1,2 level hospital. The data analysis was done by SPSS, t-test, ANOVA, Pearson correlation. The results were as follows: 1. Male to female ratio was 1.7:1 and peak age group was patients over forties and under nine years of age(70.5%) 2. Traumatic patients were 17.8%, motor vehicle accident patients were 16.7% and Non-traumatic patients were 65.3%. Transferring hospital was divided into 2groups: primary hospital, secondary hospital. The majority was secondary hospital(73.3%). The result of symptom severity classification of patients transferred to 3rd emergency medical center was urgent patients 32.5%, emergency patients 33.58%, non-emergency patients 34.0% 3. Most highest score items amoung overlapping reexamination of patients transfered to emergency medical center of university hospital from 1,2 level hospital were CBC test, simple X-ray (0.93점), CBC test(0.97점), urin test(0.88점), chemistry test(0.94점), simple X-ray(0.98점), CT(0.42점), EKG(0.89점) amoung overlapping reexamination of motor vehicle accident patients were more higher reexamination score than traumatic patients and non-traumatic patients 4. CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.001), CT(P<0.01), EKG(P<0.001) amoung overlapping reexamination of patients in 2 level hospital were more higher reexamination score than 1 level hospital patients 5. About symptom severity classification of patients transferred to 3rd emergency medical center, CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.01), CT(P<0.001), EKG(P<0.001) amoung overlapping reexamination items in urgent patients were more higher reexamination score than other patients 6. Influencing variation for overlapping reexamination in hospital was CBC test(P<0.001), CT (P<0.001), MRI (P<0.05).

  • PDF