• Title/Summary/Keyword: 7-Zone-diagnosis

Search Result 41, Processing Time 0.024 seconds

The Characteristics of 7-zone-diagnosis on Postpartum Depression (산후우울군과 비우울군의 7구역 진단기 특성연구)

  • Bak, Ji-Young;Lee, Eun-Hee;Ban, Ji-Hye;Kim, Tae-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.24 no.3
    • /
    • pp.146-155
    • /
    • 2011
  • Objectives: Since early developed measurement of Postpartum depression(PPD) doesn't reflect physical symptoms, we need to find out how PPD and related physical disorders are expressed in functional medical methods. The study was conducted to find out characteristics of 7 Zone diagnosis and postpartum physical symptoms on PPD. Methods: To 216 postpartum women who did normal delivery, we measured 7-zone-diagnosis Factor AA's height on 5th day and 15th day postpartum. And we surveyed EPDS and postpartum physical symptoms question on 15th day postpartum. Subjects were divided into normal and depression group by EPDS score. And we compared Factor AA's height between two groups and Factor AA's height change in each group. Results: In depression group, Factor AA's height was higher than normal group on 5th day and 15th day postpartum. In both groups Factor AA's height was decreased on 15th day compared to 5th day postpartum. In normal group 2, 6, 7 zone were significantly decreased and in depression group only 6 zone was significantly decreased. Conclusions: These results demonstrate that postpartum depression group has low recuperative power. And these can be judged by Factor AA's height change.

A Study on the Clinical Use of 7-zone-Diagnostic System (2) - the Comparative Analysis of the Rule and the Decipher for each Equipment - (7구역진단기의 임상응용에 대한 고찰 (2) - 각 제품에 따른 원리와 판독의 비교 -)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.11-21
    • /
    • 2006
  • The 7-zone-diagnostic system(ABR-2000, BIO MEDIC 700Plus, CP-6000A, OMD 3000, VEGA-DFM 722) is a diagnostic device which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result charts. And these result represents various characteristic signals are assisted diagnosis and care. These result chart contains disorder flow wave forms and some valuable diagnostic hints or marks. But we have several various products for the 7-zone-diagnostic system. I think that we need the comparative analysis of the general rule and the decipher for each equipment. Because these letters(marks) each product are different, we necessary various plentiful research and suitable statistics in these points. And we must carry out many various research in the future.

  • PDF

A Clinical Study of the Relation between the 7-Zone-Diagnostic System and Heart Rate Variability (7구역진단기와 심박변이도의 연관성에 대한 임상연구)

  • Song, Beom-Yong;Kwon, Kyong-Suk
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.15-23
    • /
    • 2008
  • Objectives : The aim of our study was to demonstrate the clinical application of a diagnosis relating the 7-zone-diagnostic system and heart rate variability. Materials and Methods : Subjects were divided into two groups according to the factor AA form of the 7-zone-diagnostic system(VEGA-DFM722, VEGA, Germany). Subjects in group A showed a factor-AA red bar graph in which zone 2 was higher than the normal range, and zone 6 was lower than the normal range. Subjects in group B showed a factor-AA red bar graph in which zone 2 was lower than the normal range, and zone 6 was higher than the normal range. We investigated how to differentiate the index of heart-rate variability(HRV, LX-3202, LAXTHA, Korea) for each group. We did independent sample t-tests and evaluated the results of the HRV at the 5% significance level using SPSS 10.0 for Windows. Results : The differences of the MeanRR, MeanHRV, SDNN, complexity, HRV-index, RMSSD, SDSD, and pNN50 values between the groups was not significant. The differences of the Ln(TP), Ln(VLF), Ln(HF), LF/(LF+HF), LF/HF, norm LF, and norm HF values between the groups was also not significant. The differences were not significant, but generally the values of SDNN, complexity, RMSSD, SDSD, Ln(VLF), Ln(HF) and norm LF for group B were higher than those for group A, and the values of pNN50 and norm HF for group B were lower than those for group A. Conclusions : This study suggests that differences in the HRV values between the groups was not significant, but group B has a tendency to be healthier than group A because of stress. Accordingly, further study will be required.

  • PDF

A Study on the Clinical Use of 7-zone-diagnostic System(1) Centering around VEGA-DFM 722 and ABR-2000- (7구역진단기의 임상응용에 대한 고찰(1) -VEGA-DFM 722 및 ABR-2000 중심으로-)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • Functional medicine is a system which utilizes certain investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. Functional disorders take place on an energetic plane. This plane is not capturable using our regular investigatory techniques, such as X -ray. ultrasound, computer tomography and laboratory analyses. The 7-zone-diagnostic system(VEGA-DFM 722 and ABR-2000, etc) is a diagnostic device Which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. The skin has many functions as an organ. It is the organism's interlace with the outsider world. Hence, the manner in which the skin reacts to external stimuli reflects the current state of the organism(as meridian systems). This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result chart. This result chart contain disorder flow wave forms and some valuable diagnostic hints (letters ; S, OM, RA, etc). In spite of this 7-zone-diagnostic system that is applied plentifully in the clinical application, there is not a statistics which is suitable. Therefor we must carry out many various research in the future.

  • PDF

A Study on the Change of Digital Infrared Thermographic Imaging and Skin Resistance Variability before and after Treatment of Dysmenorrhea (월경통 치료 전과 후의 적외선체열영상 및 피부저항변이도 변화에 대한 연구)

  • Kim, Hyeon-Ju;Lee, Yong-Hyun;Sohn, Young-Joo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.2
    • /
    • pp.88-103
    • /
    • 2013
  • Purpose: The aim of this study was to examine the effect of oriental diagnosis and treatment for dysmenorrhea patients on lower abdominal temperature and Skin Resistance Variability(SRV). Methods: We studied twenty-five dysmenorrhea patients, who visited Oriental Medicine Hospital of ${\bigcirc}{\bigcirc}$ University for 10 months(Sep. 2011~Jun. 2012). Patients with organic disease such as endometriosis, uterine myoma and pelvic inflammatory disease were excluded from this study. We prescribed 3 types of treatments, herbal medicine, acupuncture, and moxibustion, for one menstrual cycle. Digital Infrared Thermographic Imaging(DITI), 7-Zone-Diagnostic System(CP-6000A), VAS(Visual analog scale) and MVRS(Multidimensional verbal rating scale) were conducted before and after the treatment. The result of DITI, 7-Zone-Diagnostic System, VAS and MVRS before and after treatment were compared in order to objectively assess the therapeutic effect. Results: When we compared the results of DITI, CV4 temperature after treatment was increased compared with that of before, and temperature difference between CV12 and CV4 after treatment was decreased compared with that of before. But there was no significant difference. When we compared the results of 7-Zone-Diagnostic System at 1st and 2nd trial, the height of 1~5 area was lower than that of before. And at 1st and 2nd trial, the height of 6, 7 area was higher than that of before, but there were no significant difference in most. When we compared the results of VAS and MVRS, VAS and MVRS after treatment was significantly decreased compared with that of before(p<0.01). Conclusions: This study shows that oriental diagnosis and treatment for dysmenorrhea patients affects the results of DITI. Further study will be needed.

A Study on the Correlation between the Patterns of the Zone 4 of Factor AA in 7-Zone-diagnostic System and Heart Rate Variability (7구역진단기의 Factor AA 제4구역 유형과 심박변이도(HRV)와의 상관성 연구)

  • Yu, Jung-Suk;Cho, Yi-Hyun;Lee, Jin-Seok;Lee, Hui-Yong;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.71-80
    • /
    • 2008
  • Objectives : The 7-zonediagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 4 of Factor AA in VEGA DFM 722 (VEGA, Germany), 7-zone-diagnositic system and heart rate variability. Methods : We made three groups according to the Factor AA patterns of VEGA DFM 722. The Factor AA pattern of Group A is that the red bar graph of zone 4 was higher than the normal range. The Factor AA patterns of Group B was that the red bar graph of zone 4 was located at the normal range. The Factor AA patterns of Group C was that the red bar graph of zone 4 was lower than the normal range. We investigated how to difference of the index of heart rate variability(HRV, LX-3202, LAXTHA, Korea) according to each groups. Results : Complexity, HRV-index, RMSSD, SDSD values of Group B were higher than other Groups. pNN50 values of Group B were lower than other groups. And Ln(TP), Ln(VLF), Ln(LF), Ln(HF) values of Group B were higher than other groups. Conclusions : We presumed that Group B was healthier than other groups for the stress.

  • PDF

Clinical Study of Discrimination of Sasang Constitution wi th 7-Zone-Diagnostic System(VEGA-DFM722) (7구역진단기(VEGA-DFM722)를 이용한 사상체질 판별 가능성에 대한 임상 연구)

  • Song, Beom-Yong;Kwon, Kyong-Suk;Song, Jeong-Mo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.82-93
    • /
    • 2007
  • 1. Objectives Functional medicine is a system which utilizes certain Investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. The 7-zone-diagnostic system(VEGA-DFM722 and ABR-2000, etc) is a diagnostic device which applies pulse signals to predetermined bodily locations. We think that we can discriminate between Soeumin, Soyangin and Taeumin with this system. 2. Methods The subject of our study is no disease men and women who are decided the same constitution both survey of the QSCC II and diagnosis of specialist of the Sasang Constitution. All subject are 76(Soeumin(N=24), Soyangin(N=17), Taeumin(N=35)) cases. We make an analysis of a distinctive feature on the result of the VEGA-DFM722. 3. Results and Conclusions 1) Soeumin or Taeumin women had that the red bar graphs of and 1, 2 and 3 are lower than the red bar graphs of zone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. Soyangin or Taeumin men had that the red bar graphs of zone 1,2 and 3 are higher than the red bar graphs of tone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. 2) The typical discrimination between Soeumin and Soyangin showed statistical significance(p<0.05) in Factor PF 4(red bar) on the result of VEGA-DFM722.

  • PDF

An Experimental Study on Flame Structure and Combustion Characteristics of Turbulent Diffusion Flame(III) (난류확산화염의 화염구조와 연소특성에 관한 실험적 연구)

  • Jang, In-Gap;Choe, Gyeong-Min;Choe, Byeong-Ryun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2326-2336
    • /
    • 1996
  • So most practical combustor is considered to the swirl flame, it is very important to examinate swirl flame structure and combustion characteristics. Recently, attention has been paid to the flame diagnostic by radical luminous intensity. For swirl flame structure and combustion characteristic, reverse flow boundary, temperature, ion current and radical luminous intensity were measured in the double-coaxial swirl combustor which was used principle of multi-annular combustor. This study had three experimental condition, S-type, C-type, SC-type. S-type and C-type flames were formed recirculation zone, but SC-type flame wasn't formed. C-type flame had two recirculation zone. The position with maximum value of ion current and CH-radical, temperature and OH-radical had similarity distribution almost. Therefore, it is possible that the macro structure of flame was measured by radical luminous intensity in the high intensity of turbulent combustion field which was formed by swirl.

Diagnostic Strategy Using Barium Enema and Rectal Suction Biopsy with Acetylcholinesterase Histochemistry in Neonates with Suspious Hirschsprung's Disease (신생아 Hirschsprung's Disease에서 Barium Enema와 Acetylcholinesterase 조직화검사법을 이용한 진단적 접근)

  • Choi, Young-Il;Choi, Soon-Ok;Park, Woo-Hyun
    • Advances in pediatric surgery
    • /
    • v.7 no.2
    • /
    • pp.105-111
    • /
    • 2001
  • To investigate the diagnostic accuracy and applicability of barium enema(BE) and rectal suction biopsy with acetyl cholinesterase(AChE) histochemistry in the diagnosis of neonatal Hirschsprung's disease(HD), we retrospectively reviewed the findings of BE and AChE staining in 96 neonates with suspected HD during a 10-year period from January 1991 to December 2000. Sixty-nine cases of HD(58 males and 11 females) and 27 cases of non-HD are included in this study. In regard to BE, HD was based on definite transitional zone, suspicious HD on reversed rectosigmoid index(RSI <1), and non-HD on normal RSI(RSI>1). The histochemical criterion used for the diagnosis of HD was that of Chow et al(1977), i.e., the presence of many coarse discrete cholinergic nerve fibers in the muscularis mucosae and in the immediately subjacent submucosa regardless of infiltration of cholinergic nerve fibers in the lamina propria. Of 66 neonates with HD who underwent BE, transitional zone was identified in 33 cases(50 %) and reversed RSI in 19 cases(21 %), microcolon in 4 cases and normal finding in 10 cases(15 %) while of 27 neonates with non-HD, there was normal finding in 16 cases and reversed RSI in 9 cases(41 %). Thus diagnostic accuracy based on transitional zone was 64 %. The positive predictive value of reversed RSI for the diagnosis of HD was 68 %. Of 42 neonates with HD who underwent AChE histochemistry, there were 41 AChE-positive reactions and one AChE-negative reaction in a neonate with total colonic aganglionosis, while of 27 cases of non-HD, there were one equivocal AChE-positive reaction and 26 AChE-negative reactions. Thus AChE histochemical study showed a 97 % diagnostic accuracy with a 98 % sensitivity and a 96 % specificity. In conclusion, we believe that BE is valuable as a first diagnostic step since about 80 % of neonates with HD show significant radiologic findings such as a transitional zone or reversed RSI. AChE histochemical study was a more reliable diagnos tic tool showing a 97 % diagnostic accuracy, and is part.

  • PDF

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.